This Installation Manual covers the setup of household appliances like washing machines and dishwashers, focusing on critical requirements such as plumbing connections (water pressure, temperature, drain systems) and electrical safety–including grounding and proper positioning. The guide emphasizes precise measurements, clearance standards (e.g., drain height), and compliance with regional regulations, ensuring safe integration into residential or commercial spaces. Multilingual support in English, Spanish, and French accommodates diverse user needs while prioritizing structural stability, drainage efficiency, and electrical compatibility.
Table of Contents:
- Page 1 – Washer Installation Requirements and Connections
- Page 2 – Initial Setup and Preparation Steps
- Page 3 – Connecting Water and Drain Hoses
- Page 4 – Dishwasher Plumbing Installation
- Page 5 – Electrical and Leveling Adjustments
- Page 6 – Special Installation and Warranty Information
INSTALLATION
REQUIREMENTS
LOCATION
Washer most be installed on firm flooring to minimize vibration during spin cycle
Concreteflooring is best, btit wood base is sufficient, providedfloor support meets
FHAstandards Washershould not be installedon rugs or exposedto weather
PLUMBING
WATERPRESSURE
- Must be 10 psi minimtim to 150 psi maximum
WATERTEMPERATURE
- Householdwater heatershould be set to deliver water
at 120" to 150°F (50° to 66°C) IN ]'HE WASHERwhen hot washis selected
SHUTOFF
VALVES- Both hot and cold shutoff valves(faucets) should be supplied
DRAIN- Water may be drainedinto standpipeor set tub DischargeheightMUST
NOT8E LESSTHAN30 INCHES,and no more than 8 feet abovethe baseof the
washerStandpipe
mustbe1-1/2 inchesminimominsidediameter
andmost be
opento atmosphere.
ELECTRICAL
REQUIREMENTS
CAUTION:Before ptuggingin washer,read the followingelectrical requirements.
CAUTION:For personalsafety,do not use an extension cord or adapterplug with
thisappliance Do not, underany circumstances,cut or removethethird
grounding prong from the power cord Follownational electrical codes and
ordinances This appliancemust be suppliedwith the voltage and frequency
indicatedon the rating plate (located on top of the backsplash),and connected
to an individual, properly grounded branch circtiit, protectedby a t5- or 20-amp
circuitbreakeror time-delaylose if theelectric sopply provideddoes not meet
the aboverequirements,carl a licensedelectrician
REQUERIMIENTOS
DEUBICAOION
PARALA INSTALACI()N
Sedebe colocarla lavadorasobre un piso firme paraminimizar la vibraci6n
duranteel ciclo de centrffugado.Lomejor es un piso de concreto Sin embargo,
una base de maderaes sufictente,siempre y coando la base del pisoctimpla
con las normasde ta FHA No se debecotocar la lavader_sobre alfombras ni
exponerlaa la intemperie
PLOMERiA
PRESIDNDEAGUA:Debesat de 0,7 kgflcm" (10 psi) comomlnimo y de 10,5
kgf/cm=(150 psi) como m_imo.
TEMPERATURA
DEAGUA:Sedeberegtilar el calentadorde agoade la vivienda
para qua propomione aguaa ona tempe atura de 50 °C a 65 °C (120 °F a 150
°FJA LA LAVADORA,
al seleocionarel ciclo de lavado en caliente
VALVULASDECIERRE:Sedeben suministrar dos v,ilvulas de cierre (flares),
una parael agoacalientey otra parala frla
DRENAJE:Se ptiededrenar elagua hacia un tubovertical ouna tina Iiia La
altura de descargaNODEUESERMENORDE76 cm 130 pulg ), ni dabe
encontrarsea m_s de 2,4 m (8 pies)de la base de la tavadora El di_metro
inferno del tubovertical debeset de 3,8 om (1o112pulg) comominting y debe
encontrarseabierto a la atm6sfera
REOUISITOS
ELECTRICOS
PRECAUOI(}N:
Antes de enchufar Ia lavadoralealos siguientes requisitos
el_ctricosi
PRECAUOION:
Parasegoddadde ias personas,no use una extensi6nel_ctrica
ni tin adaptadorconeste aparato el_ctrice Balo ntngunacircunstancia
corte o
elimine del cord6n el_ctdco la teroeraespiga para conexi6na tierra Obedezca
las regulacionesy c6digos el_ctrioosnacionatesEsteaparato el_ctricodebe set
alimentadocon el vottaiey talrecuenoia indicadosen la placade clasificaciOn
(qua se encuentraen la partesuperior de la tapa parasalpicaduras),adam,s se
te debeconectaraun circuito secundadoe individual apropiadamente
conectadoa lierra y debeestar protegido pot un disyuntor oun fosibfe con
retardo de tiempo de 15 6 20 amperios Si la fuente de alimentaci6nprovista no
oumplecon los requisitos antes mencionados,llama aun eleotricista
certificado
INSTALLATION
EMPLACEMENT
carte machine_ laver dolt_,treposse SLtrone stirface homog_nepour Iimiter
fesvibrations pendantle cycle d'essorageUnedalle an b_ton est id_ale, mals
rappareil pent_tre pos_sur un plancherenbois, pourvti qtiele support de ce
derniersoit conforme anx aortaesde la FHA L'appareifnedolt pas _tre pos_
stir on tapis ou expos_aux intemp_ries
PLOMBERIE
PRESSIOND'EAU- Celleocidoit se sittier entre un minimum de 0,7 kgflom=(t0
psi) et un maximumde 10,5 kgf!cm=(t50 psi)
TEMPERATURE
D'EAU- Le chauffe-eaudomestique doit _tre r_gt_de fa_ion
alimenterLA MACHINEA LAVERavecde i'eau chaudeentre 50 °Cet 65 °C (120
°F et 150 °F)quan_ on choisit le mode" hot wash" (lavage_ ohaud).
ROBINETS
O'ARRET- Des robinets d'arr_t d'eau chaudeet d'eau Iroide doivent
_tre pr_vus,
EVAOIJATION
- L'eaude vidangepent _tre soil _vacu_eau moyend'un tuyao de
Ptib.,N0,31-15441
renvoi,soit rejoicedansunbac&laver,L'eauDOlT
ETRE
6vacu_e
&unehauteur
MINIMALE
DE76 cm (30pc) et maximale
de2,4 m (8 pieds)parrapport_,la
basedefa machineLetuyauderenvoidoil avoirtin dtam_treint_rieurminimal
de 3,8 cm(1-1/2pc) et _tresitu__ rair libra
INSTALLATION
ELECTRIQUE
AVERTISSEMENT
: Famifiansez-vous
aveclosconsignessuivantes
avantde
branoherta machine_ laver
AVERTISSEMENT
: Potirdesraisonsde s_curit_,nepas otiliserde ratlongesoti
d'adaptateurs
_lectriques
aveccotappareilNejamaistenterdecouperou
d'enleverlabrochede raise_ la terraducordond'alimentationRespectez
los
codeset los normesenvigueurr_gissantlos installations
_fectriques
L'appareit
doit _trelivr_aveconepiaquesignal_tique
situ_edansla partie
sup_rieure
dudosseret,ouscat indiqu_sle voltageet la fr_quence
applicables,
reli6_ tin circuitded6rivationindividualmis_ la terradefa_;onappropri6eet
prot_g6par un coupe-circuitou un fusibletemporis_
de t5 ou 20 amperes
Sile circuit d'alimentationexistantnecorrespondpasaux exigences
ci-
desstis,consultezun _lectricien
DWG,NO.175D3gO4PO01
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
Helpful for 3 of 3 readers
About this manual
- Brand
- GE
- Model
- GTWN3000M1WS
- Document type
- Installation Manual
- Language(s)
- English, Spanish, French
- Pages
- 6
- File size
- 845 KB
- Format
Other Manuals for GE GTWN3000M1WS
Summary
Requirements for location, plumbing specifications (water pressure, temperature, shut-off valves, drain), electrical connections, safety warnings, and grounding specifications for installation.
Tools required, supplied parts, and initial steps for removing packaging, positioning the machine, and preparing it for installation.
Step-by-step instructions for connecting drain hoses and water supply hoses, including diagrams illustrating component connections.