GE DBXR463ED1WW - Installation Manual

GE DBXR463ED1WW

An Installation Manual for electric dryers outlines essential setup procedures, including preparation steps like ductwork assembly, electrical wiring (with 3-wire connections), grounding requirements, and exhaust venting standards. The guide emphasizes safety–such as proper duct sealing, insulation for unheated areas, and compliance with outdoor venting regulations–to ensure safe operation. It also covers specialized configurations, like indoor venting in alcoves or mobile homes, and provides diagrams for leveling, cabinet modifications, and flexible duct connections.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 1 – Electric Dryer Installation Overview
  • Page 2 – Electrical Connection and Grounding Requirements
  • Page 3 – Exhaust System Sizing and Duct Installation Details
  • Page 4 – Exhaust Venting and Leveling Procedures
  • Page 5 – Indoor Venting Requirements and Safety Standards
  • Page 6 – Exhaust Duct Connection to Cabinetry
  • Page 7 – Cabinet Integration and Servicing Precautions
Loading the manual
Page 1

Installation
Instructions

Electric

Dryer

37

I

Questions

on Installation?

Call: 1-8OO-GECARES

(US)

or Visit our Web

site at:

www.GEAppliances.com

(US)

BEFOREYOU BEGIN

Read

these

instructions

completely

and

carefully.

•IMPORTANT

- Save

these

instructions

for local

inspector's

use.

•IMPORTANT

- Observe

all

governing

codes

and

ordinances.

• Note

to Installer

- Be sure to leave

these

instructions

with

the customer.

• Note

to

Customer

- Keep

these

instructions

with your

Use

and

Care

Book

for furore

reference.

• Exhausting

the dryer

to the outdoors

is strongly

recom-

mended

to prevent

large amounts

of moisture

from

being

blown

into

the room.

• Before

the old dryer

is removed

from

service

or discarded,

remove

the dryer

door.

• Service

information

and

the wiring

diagram

are located

in

the control

console.

• Do not allow

children

on or in the appliance.

Close

supervision

of children

is necessary

when

the appliance

is

used

near

children.

FOR YOUR SAFETY:

WARNING

• Use only rigid metal or flexible metal 4-in. diameter

ductwork

for exhausting

to tile outdoors.

Never

use plastic or other combustible,

easy-to-puncture

ductwork.

• This appliance

must be properly

grounded

and installed

as described

in these instructions.

• Do not install or store appliance

in an area where it

will be exposed

to water and/or

weather

• Install tile dryer where the temperature

is above ,50°F

for satisfactory

operation

of the dryer control system.

NOTE: Installation

and service

of this dryer

requires

basic mechanical

and electrical

skills.

It is your responsibility

to contact

a qualified

installer

to make the electrical

connections,

I

TOOLS YOU

WILL NEED

SLIPJOINTPLIERS

[_

FLATBLADE

SCREWDRIVER

PHILLIPS

SCREWDRIVER

MATERIALS YOU WILL NEED

4" DIA.METALDUCT

4"

(RECOMMENDED)

DUCT

CLAMPS

(2)

OR
4"SPRING
CLAMPS

(2)

4" DIA.FLEXIBLE

METALDUCT

(IFNEEDED)

%

4" DIA.METAL

ELBOW

EXHAUST

HOOD SAFETY

GLASSES

_

3/4"_RELIEF

DUCTTAPE

GLOVES

ULRECOGNIZED

DRYER

POWER

CORDKIT

(NOTPROVIDED

WITHDRYER)

ULRATED

120/240V,

30A

WITH3 OR4 PRONGS.

IDENTIFY

THEPLUG

TYPE

ASPERTHEHOUSE

RECEPTACLE

BEFORE

PURCHASING

LINECORD.

Step

1

Step 2

Step 3

Step 4

Step 5

Step 6

Step 7

Prepare

the Area and Exhaust for Installation

of

New Dryer (see section 1).

Check and Ensure the Existing External

Exhaust

is

Clean (see section 1) and Meets Attached

Installation

Specifications

(see section 3).

Remove

the Foam Shipping Pads (see section

1).

Move the Dryer to the Desired Location.

Connect

the Power Supply

(see section 2).

Connect

the External

Exhaust (see section 4).

Level Your Dryer (see section ,_).

Step 8

Step

9

Check the Operation

of the Power Supply

and Venting.
Place the Owners Manual

and the Installation

Instructions

in a Location Where They Will Be

Noticed By tile Owner.

For Alcove or Closet Installation,

see section 6.

For Bathroom

or Bedroom

Installation,

see section 7.

For Mobile or Manufactured

Home see, section 8.

For side or bottom

exhaust,

see section 9.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
GE
Model
DBXR463ED1WW
Document type
Installation Manual
Language(s)
English
Pages
8
File size
615.6 KB
Format
PDF

Other Manuals for GE DBXR463ED1WW

Summary

Page 1 - Electric Dryer Installation Overview

Instructions for setting up the Electric Dryer 37, including safety warnings, required tools, materials, and step-by-step procedures for preparation, exhaust connection, power supply, and leveling.

Page 2 - Electrical Connection and Grounding Requirements

Detailed instructions for dryer installation focusing on duct setup, removing shipping pads, electrical connection requirements, grounding procedures, wiring diagrams, and safety warnings.

Page 3 - Exhaust System Sizing and Duct Installation Details

Guidance on electrical connections and exhaust system setup, including step-by-step wiring for a 3-wire connection, terminal block safety, calculating exhaust duct length based on hood type and elbow turns, and requirements for hood/wall cap installation and insulation.