Garland M/MST35 - Manual

Garland M/MST35

Garland M/MST35 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – KEEP AREA FREE FROM COMBUSTIBLES; This product contains chemicals known; IMPORTANT INFORMATION
  • Page 3 – TABLE OF CONTENTS; Draining and Filtering Of Fryer Compound 14
  • Page 4 – DIMENSIONS AND SPECIFICATIONS, MODEL M/MST35
  • Page 5 – DIMENSIONS AND SPECIFICATIONS, MODEL M/MST70
  • Page 6 – INSTALLATION
  • Page 7 – A. The installation shall be made with a connector; Legs; These types of GARLAND Fryers cannot; INSTALLATION Continued
  • Page 8 – Ventilation and Air Supply; NOT; be; Assembly Of Battery; A. All such units should be placed in their respective
  • Page 9 – E. The manifold of this unit or the manifold of which; Assembly Instructions M-Series Backguard; If unit is in a battery line up, fasten adjacent units
  • Page 10 – Using the Fryer for the First Time; OPER ATION; Radiation Shield
  • Page 11 – OPER ATION Continued; Lighting Instructions; Frypot must be filled before lighting; OFFP; NOTE: Fryer cannot be shut off at the thermostat.; Stand By
  • Page 12 – Optimum Operation Tips; Suggestions for Quality Fried Food
  • Page 13 – Do not shake breaded items over the fryer.; Routine Care; Cleaning; Painted Finishes; Wipe exposed, cleanable surface when cool with
  • Page 15 – CLEANING AND MAINTENANCE Continued; Preventive Maintenance; Check main burner flames for good ignition and; TROUBLE SHOOTING AND ADJUSTMENTS; Adjustments; Trouble Shooting
  • Page 16 – TROUBLE SHOOTING AND ADJUSTMENTS Continued; Thermostat Calibration
  • Page 17 – NOTES
  • Page 20 – Dépan
  • Page 21 – Entretie; Entr
  • Page 22 – Nett
  • Page 32 – o N
Loading the manual

Part # 1382677 (08/06)

Page 1

INSTALLATION, OPERATING

& SERVICE INSTRUCTIONS

FOR MASTER SERIES

HEAVY DUTY GAS FRYERS

MODELS M/MST35 & M/MST70

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER

FLAMMABLE VAPORS OR LIQUIDS IN THE

VICINITY OF THIS OR ANY OTHER APPLIANCE.

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT,

ALTERATION, SERVICE OR MAINTENANCE CAN

CAUSE PROPERTY DAMAGE, INJURY OR DEATH.

READ THE INSTALLATION, OPERATION AND

MAINTENANCE INSTRUCTIONS THOROUGHLY

BEFORE INSTALLING OR SERVICING

THIS EQUIPMENT.

PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE.

THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED

BY PROFESSIONAL PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS THIS PRODUCT MUST BE INSTALLED BY A LICENSED
PLUMBER OR GAS FITTER. APPROVAL NUMBER: G-1-07-05-28

For Your Safety:

Post in a prominent location, instructions to be followed in the event the user smells gas. This information shall be

obtained by consulting your local gas supplier.

Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine
Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed,

adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided

with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified

or repaired using unauthorized parts or by unauthorized service agents. For a list of authorized service agents, please refer
to the Garland web site at http://w w w.garland-group.com. The information contained herein, (including design and parts

specifications), may be superseded and is subject to change without notice.

Continuous product improvement is a Garland policy, therefore design and specifications are subject to change without notice.

GARLAND COMMERCIAL INDUSTRIES

185 East South Street

Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903

GARLAND COMMERCIAL RANGES,
LTD.

1177 Kamato Road, Mississauga, Ontario L4W 1X4

CANADA
Phone: 905-624-0260
Fax: 905-624-5669

Enodis UK LTD.

Swallowfield Way, Hayes, Middlesex UB3 1DQ ENGLAND

Telephone: 081-561-0433

Fax: 081-848-0041

Part # 1382677 (08/06)

© 2005 Garland Commercial Industries, Inc.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - KEEP AREA FREE FROM COMBUSTIBLES; This product contains chemicals known; IMPORTANT INFORMATION

Part # 1382677 (08/06) Page 2 KEEP AREA FREE FROM COMBUSTIBLES WARNING: This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glasswool/cer...

Page 3 - TABLE OF CONTENTS; Draining and Filtering Of Fryer Compound 14

Part # 1382677 (08/06) Page 3 TABLE OF CONTENTS Important Information. . . . . . . . . . . . . . . . 2 Dimensions And Specifications, Model M/MST35 . . . . . . . . . . . . . . . . . . . . 4 Dimensions And Specifications, Model M/MST70 . . . . . . . . . . . . . . . . . . . . 5 Installation . . . . . . ...

Page 4 - DIMENSIONS AND SPECIFICATIONS, MODEL M/MST35

Part # 1382677 (08/06) Page 4 3-1/2" [89mm] 34-3/8" [873mm] 13-1/8" [333mm] 37-7/8" [962mm] 33-3/8" [848mm] 30-1/4" [768mm] 6" [152mm] 1-1/4" N.P.T.[32mm]GAS INLET 63-3/4" [1619mm] With "DDBG" BACKGUARD 46-3/4" [1187mm]With "BG" BACKGUARD 40-1/...

Other Garland Models

All Garland Other