Table of Contents:

  • Page 2 – CAUTION; For microwave energy emission
  • Page 3 – ADJUSTMENT PROCEDURES; Figure 1
  • Page 6 – TEST PROCEDURES AND TROUBLESHOOTING; Figure 4; ) Check for resistance: Between each filament; Figure 3
  • Page 7 – NOTE; Figure 7
  • Page 13 – DISASSEMBLY INSTRUCTIONS; A. REMOVING INTERLOCK SWITCH; (1) Disconnect all lead wires from the interlock; NOTES
  • Page 16 – Light
Loading the manual

FORM # EM-C180 (02/05)

SERVICE MANUAL SUPPLEMENT

for Model EM-C180

Microwave Oven

CAUTION

WARNING TO SERVICE TECHNICIANS

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING

SERVICING TO AVOID POSSIBLE EXPOSURE TO

EXCESSIVE MICROWAVE ENERGY

(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary:
(1)Interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other
damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation

and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual
before the oven is released to the owner.

(e)(i) A microwave leakage check to verify compliance with the Federal performance standard should be
performed on each oven prior to release to the owner. (For U.S.A)
(e)(ii) A microwave leakage check to verify compliance with the Canadian Regulation, HEALTH AND WELFARE,

SOR/79-920 should be performed on each oven prior to release to the owner. (For CANADA)

SUPPLEMENT OF
SERVICE MANUAL

Microwave Oven

EM-C160US

REFERENCE NO.

SM-640180

See the Service Manual of

EM-C180US(SM-640179)

except the items described in this Service Manual.

PRODUCT CODE NO. 437-453-00

CAUTION

WARNING TO SERVICE TECHNICIANS

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING

SERVICING TO AVOID POSSIBLE EXPOSURE TO

EXCESSIVE MICROWAVE ENERGY

(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary:
(1)Interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other
damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation

and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual
before the oven is released to the owner.

(e)(i) A microwave leakage check to verify compliance with the Federal performance standard should be
performed on each oven prior to release to the owner. (For U.S.A)
(e)(ii) A microwave leakage check to verify compliance with the Canadian Regulation, HEALTH AND WELFARE,

SOR/79-920 should be performed on each oven prior to release to the owner. (For CANADA)

SUPPLEMENT OF
SERVICE MANUAL

Microwave Oven

EM-C160US

REFERENCE NO.

SM-640180

See the Service Manual of

EM-C180US(SM-640179)

except the items described in this Service Manual.

PRODUCT CODE NO. 437-453-00

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CAUTION; For microwave energy emission

CAUTION For microwave energy emission On every service call. A check for micro-wave energy emission must be madeaccording to the following manner. Measurement of energy emission Measurement must be made with the microwave ovenoperating at its maximum output and containing a load of 275 ± 15 millilit...

Page 3 - ADJUSTMENT PROCEDURES; Figure 1

- 3 - - TABLE OF CONTENTS - Adjustment Procedures ............................................. 1Specifications ............................................................ 2Power output Measurement ...................................... 2Precautions and Repair Service Tips ....................... 2...

Page 6 - TEST PROCEDURES AND TROUBLESHOOTING; Figure 4; ) Check for resistance: Between each filament; Figure 3

- 6 - 6. TEST PROCEDURES AND TROUBLESHOOTING CAUTION -DISCONNECT THE POWER SUPPLY CORD FROM THE WALLOUTLET WHENEVER REMOVING THE CABINET FROM THE UNIT.PROCEED WITH TESTS ONLY AFTER DISCHARGING THE HIGHVOLTAGE CAPACITORS AND REMOVING THE LEAD WIRES ONTHE PRIMARY WINDING OF THE HIGH VOLTAGE TRANSFORM-...

Other Garland Models