Frigidaire GMBD3068AFA - Installation Manual
Frigidaire GMBD3068AFA – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – BUILT-IN MICROWAVE INSTALLATION INSTRUCTIONS; trim does not lie flush against the cabinet, or if noise; to floor; Do not lift or manipulate the oven door handle; Cabinet Installation
- Page 4 – Outlet
- Page 5 – Install Mounting Screws; Use the two screws supplied to fix the appliance to; Model and Serial Number Location; Use and Care Guide; Minimum Cutout Overlap; Mounting Holes
- Page 6 – PARA SU SEGURIDAD: No almacene ni use gasolina u otros vapores; MICROONDAS INCORPORADO - INSTRUCCIONES DE INSTALACIÓN
- Page 7 – min; Instalación del gabinete; Peligro de objeto pesado.
- Page 10 – Antes de llamar al servicio; Placa de serial; Mínima superposición; Ubicación del modelo y número de serial
- Page 11 – POUR VOTRE SÉCURITÉ : Ne pas rangez ou utilisez de l'essence ou; Notes importantes pour l'installateur; ATTENTION; INSTRUCTIONS D'INSTALLATION DE MICRO-ONDES INTÉGRÉE
- Page 12 – INSTRUCTIONS D'INSTALLATION DE MICRO-ONDES NTÉGRÉE; Installation du meuble; Risque important pour le poids
- Page 15 – Avant d'appeler le service; Plaque de numéro de série; Superposition minimale découpée; Modèle et emplacement du numéro de série
BUILT-IN MICROWAVE INSTALLATION INSTRUCTIONS
Important Notes to the Installer
1. Read all of the installation instructions before instal-
ling the microwave oven.
2. Remove all packing material from the oven compart-
ments before connecting the electrical supply to the
microwave oven.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consu-
mer.
5. The oven door may be removed to facilitate installa-
tion.
Important Notes to the Consumer
Keep these instructions with your Owner's Guide for the
local electrical inspector's use and future reference.
IMPORTANT SAFETY INSTRUCTIONS
•
Be sure your microwave oven is installed and
grounded properly by a qualified installer or service
technician.
•
This microwave oven must be electrically grounded
in accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA No.
70- latest edtion in the United States, or with CSA
Standard C22.1, Canadian Electrical Code, Part 1, in
Canada.
Stepping, leaning, or sitting on the door
of this microwave oven can result in serious injuries and
can also cause damage to the microwave oven.
•
Never use your microwave oven for warming or hea-
ting the room. Prolonged use of the microwave oven
without adequate ventilation can be dangerous.
The electrical power to the microwave
oven must be shut off while line connections are being
made. Failure to do so could result in serious injury or
death.
1.
Carpentry
Refer to figure 2, 3, or 4 for the dimensions applicable to
your appliance and the space necessary to receive the
oven. The oven support surface may be solid plywood or
similar material, however, the surface must be level from
side to side and from front to rear.
2.
Electrical Requirements
This appliance must be supplied with the proper voltage
and frequency, and it must be connected to an individual,
properly grounded branch circuit protected by a circuit-
breaker or fuse.
Electrical Requirements:
•
A three-prong grounded outlet
•
120 V, 60 Hz, AC only
•
breaker
•
Figure 1: 3-prong 15-Amp Grounded Outlet
PN A06823525 (2021.07)
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
Your new microwave oven has been designed to fit a limited variety of cutout sizes to make
the job of installing easier. The first step of your installation should be to measure your current
cutout dimensions and compare them to the cutout dimensions chart below for your model.
You may find little or no cabinet work being necessary.
United States
and Canada
15 Amp electrical supply with a fuse or a circuit
15 Amp outlet duplex must be used
1
English – pages 1-5
Español – páginas 6-10
Français – pages 11-15
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
BUILT-IN MICROWAVE INSTALLATION INSTRUCTIONS All dimensions are in inches (cm). PRODUCT DIMENSIONS MODEL A B C D CUTOUT DIMENSIONS AND CABINET WIDTH MODEL F G H I Min. Max. Min Min. Max. Min. 28 28-3/8 22 17-3/4 18 30-1/8 NOTES: 1. The base must be capable of supporting 155 pounds (70 kg). 2. Allow ...
BUILT-IN MICROWAVE INSTALLATION INSTRUCTIONS PRODUCT DIMENSIONS MODEL A B C D CUTOUT DIMENSIONS AND CABINET WIDTH MODEL F G H Min. Max. Min Min. Max. 28 28-3/8 22 17-3/4 18 NOTES: 1. The base must be capable of supporting 155 pounds (70 kg). 2. Allow at least 21" (53.3 cm) clearance in front of ...
BUILT-IN MICROWAVE INSTALLATION INSTRUCTIONS 4. Install Mounting Screws The microwave oven can tip when the door is open. The mounting screws supplied with the microwave oven must be installed to prevent tipping of the microwave oven and injury to persons. 1. The mounting holes in the side trims may...