Frigidaire FFRE15L3S10 - Installation Manual
Frigidaire FFRE15L3S10 – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Installation Instructions; Check for anything that could block airflow
- Page 3 – Remove Air Conditioner from Cabinet; NOTE: Remove any packaging material from cabinet exterior.; Install Top Angle Rail and Side Retainers; Window Mounting
- Page 4 – Place Cabinet in Window
- Page 5 – Extend Window Filler Panels and attach to top angle rail:; Install Window Sash Seal and Safety Lock; CAUTION: Do not push on controls OR finned coils.; Attach Window Filler Panels to Window Frame
- Page 6 – Install Insulation Panel; Measure the inner width
- Page 7 – IMPORTANT: Side louvers must never be blocked.; Prepare Wall; Select Wall Location
- Page 8 – Prepare and Install Cabinet
- Page 9 – Masonry Construction
Preliminary instructions:
READ BEFORE INSTALLING UNIT
1
1. Check window opening size:
the mounting parts
furnished with this air conditioner are made to install in
a wooden sill double-hung window. The standard parts
are for window dimensions listed above. Open sash to
a minimum of 19″ (483mm). (FIG.1)
Heavy duty
NOTE: DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED HERE.
Do the following before starting to install unit. See illustrations below.
Check dimensions of your unit to determine model type:
Medium
Unit Height:
Unit Width:
Min. Window Opening:
Min. Window Width:
Max. Window Width:
18-5/8″
17-5/8″
26-1/2″
23-5/8″
19-1/2″
18-1/2″
31″
28″
42″
40-1/2″
2. Check condition of window:
all wood parts of window
must be in good shape and able to firmly hold the needed
screws. If not, make repairs before installing unit.
3. Check your storm windows:
If your storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown (FIG.2), or by removing
storm window while room air conditioner is being installed.
15,000~18,500 BTU
22,000~28,500 BTU
sash
1/2″ min
storm window frame or
other obstruction
FIG.1
19″ min
inner sill
outer sill
Capacity:
FIG.2
sash
1/2″ min
storm window frame or
other obstruction
19″ min
board thickness as
required, along entire inner
window sill; fasten to inner
sill with two nails or screws.
1-1/2″ min
inner sill
outer sill
16120300A04422
For Medium
(15,000-18,500 BTU)
+ Heavy duty
(22,000-28,500 BTU)
Air Conditioner
Pay attention to danger and safety notices.
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may
be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install
the unit. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. To
prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit overan extended
period of time.
Handle air conditioner with care.
Make sure air conditioner does not fall during installation.
If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing unit.
Carefully read the installation manual before beginning.
Follow each step as shown.
Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.
INSTALLATION WARNINGS AND CAUTION
window sash seal
safety lock and
1/2″ long hex
head screw
top angle
foam gasket
washer head
locking screw
frame
assembly
(left)
side retainer
bottom rail
seal to unit
frame
assembly
(right)
1/2″ long
screws and
locknuts
locknut 3/4″
long flat
head bolt
sill angle
bracket
window
support bracket
insulation
panel
Installation Instructions
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
5. Check the available electrical servicePower supply must be the same as that shown on the unit serial nameplate. (See Use & Care Guide for serial plate location.) Powercord is 48″ long. Be sure you have an outlet near. Installation Instructions 4. Check for anything that could block airflow Ch...
3 Installation Instructions Remove Air Conditioner from Cabinet NOTE: Remove any packaging material from cabinet exterior. 1 1. Pull down on front grille from upper edge. Lift front grille upwards and place to one side. (See FIG.1)2. Remove filter. To remove, grasp in the middle on each side. Bow fi...
FIG.13A 1/2″ longHEX-HEADSCREW 4 Installation Instructions Place Cabinet in Window 4 Top window filler panel leg WINDOW FILLERPANEL SIDE RETAINER TOP VIEW AIR CONDITIONER CABINET PLASTICFRAME “ I ” SECTION LOCKINGSCREW HOLE WINDOWFILLERPANEL FIG.11 A. #10 X 1/4″ pan-head Phillips screwsB. Safety Loc...