Friedrich WY10B33A-B - Manual
Friedrich WY10B33A-B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS
- Page 3 – FIRST YEAR
- Page 4 – ROUTINE MAINTENANCE
- Page 5 – FRIEDRICH ROOM MODEL NUMBER CODE; th DIGIT - ALPHABETICAL MODIFIER; ELECTRIC HEAT MODELS; th DIGIT; Major Change; Year Manufactured; RAC SERIAL NUMBER IDENTIFICATION GUIDE
- Page 6 – PERFORMANCE DATA
- Page 7 – ELECTRIC SHOCK HAZARD.; ELECTRICAL DATA
- Page 8 – FUNCTIONAL COMPONENTS; A. Mechanical components; MoneySaver; C. Hermetic components
- Page 9 – TESTING THE ELECTRONIC CONTROL; Figure 6: System Control Panel
- Page 10 – Figure 7: System Control Panel; Disables compressor at 35 degrees
- Page 11 – IMPORTANT; Refrigerant System Components; REFRIGERATION SYSTEM SEQUENCE OF OPERATION; SEALED REFRIGERATION SYSTEM REPAIRS
- Page 13 – Recover all refrigerant and oil from the system.; REFRIGERANT CHARGE
- Page 14 – NORMAL FUNCTION OF VALVE; POSSIBLE CAUSES; MALFUNCTION OF VALVE; TROUBLESHOOTING TOUCH TEST CHART: TO SERVICE REVERSING VALVES
- Page 15 – COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS
- Page 19 – HEAT / COOL ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS
WS08B10A-C
WS10B10A-C
WS14B10A-C
WS10B30A-C
WS13B30B-C
WS16B30A-C
WE10B33A-B
WE13B33B-B
WE16B33A-B
WY10B33A-B
WY13B33A-B
WM-Svc-Prts-07 (3-07)
Service & Parts Manual
WallMaster
®
Thru-the-Wall
Temp/Hour
Cool
Money Saver
®
Fan Only
Clock
Start Time
Stop Time
Power
Fan
Speed
Mode
PM
Timer
On/Off
Set
Hour
72
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 TABLE OF CONTENTS Warranty .....................................................................................................................................................3 Routine Maintenance .......................................................................................................
3 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedrich.com WALLMASTER £ THRU-THE-WALL AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from d...
4 ROUTINE MAINTENANCE NOTE: Units are to be inspected and serviced by qualifi ed service personnel only. Inspect the indoor blower housing, evaporator blade, condenser fan blade, and condenser shroud periodically (yearly or bi-yearly) and clean of all debris (lint, dirt, mold, fungus, etc.) Clean th...