Friedrich SS15N30* - Manual

Friedrich SS15N30*

Friedrich SS15N30* – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
Page: / 95

Table of Contents:

  • Page 2 – Table Of Contents
  • Page 3 – IMPORTANT SAFETY INFORMATION; PERSONAL INJURY OR DEATH HAZARDS; Your safety and the safety of others are very important.; WARNING; NOTICE
  • Page 4 – REFRIGERATION SYSTEM REPAIR HAZARDS:
  • Page 5 – PROPERTY DAMAGE HAZARDS; WATER DAMAGE HAZARDS:
  • Page 6 – INTRODUCTION; Register your air conditioner; MODEL AND SERIAL NUMBER LOCATION
  • Page 7 – Model Number Code; RAC Serial Number Identification Guide; UNIT IDENTIFICATION
  • Page 8 – SPECIFICATIONS; REFRIGERATION SYSTEM PERFORMANCE DATA
  • Page 9 – Installation Information / Sleeve Dimensions; Circuit Rating/ Breaker; Keep the filter clean; For the best cooling performance and highest energy efficiency
  • Page 10 – ELECTRICAL DATA; ELECTRIC SHOCK HAZARD; FIRE HAZARD
  • Page 11 – Electrical Shock Hazard; Do not use the LCDI device as an ON/OFF switch.
  • Page 12 – Kuhl Control Options; Kühl Control Options; Customizable Programming Options:; Wireless Programming and Control:; FriedrichLinkTM Adapter
  • Page 13 – Control Panel and Display Identification; AUTO SPEED
  • Page 14 – Control Panel Operation Instructions
  • Page 16 – Control Panel Lock; External Control Status; Wait Icon
  • Page 17 – To Turn On the Timer or Schedule Selected
  • Page 18 – Timer Start Time
  • Page 19 – Set theTimer Stop Time; Timer ON Scenarios
  • Page 20 – Timer OFF Scenarios
  • Page 21 – SIDE VIEW; Remote Control Operation; Remote Effectiveness
  • Page 23 – UNIT OPERATION; Front Panel; System Mode: Cool Only Units
  • Page 24 – ELECTRONIC CONTROL SEQUENCE OF OPERATION; Compressor and Reversing Valve Control; Compressor Operation:; Cooling Mode; Active Mode
  • Page 25 – Satisfied Point; Heating Mode Control Operation; Heat Pump with Electric Heat and Cool with Electric Heat.; YS10M10 Heat Pump Defrost Cycle Operation; the heat pump heat will resume.
  • Page 26 – If Electric Heat is Available; Hot; Condition 1; Heat Pump With Electric Heat Operation
  • Page 27 – Condition 2; temp is greater than the electric heat threshold.; Automatic Emergency Heat; temperature for 5 or more degrees for 5 consecutive minutes.; Electric Heat Operation in Cool with Electric Heat Units; Auto Heating Set Point will adjust accordingly.; Automatic Change Over Delay (Cool with Heat Units); Heat Pump With Electric Heat Operation (Continued)
  • Page 29 – Speed Selection; Continuous; Fan; Mode; Table; Fan ICON Detail; ng t
  • Page 30 – REMOVING THE FRONT COVER
  • Page 31 – Swing
  • Page 32 – Airflow Selection and Adjustment; Air flow direction adjustment; Fresh air and exhaust control
  • Page 33 – CAPACITORS; Capacitor Check with Capacitor Analyzer; FAN MOTOR; COMPONENTS TESTING
  • Page 34 – TESTING THE HEATING ELEMENT
  • Page 36 – REFRIGERATION SEQUENCE OF OPERATION
  • Page 37 – R-410A SEALED SYSTEM REPAIR CONSIDERATIONS; R22 equipment. Appropriate safe service and; Refrigeration system under high pressure
  • Page 38 – HIGH PRESSURE HAZARD; RISK OF ELECTRIC SHOCK; R-410A SEALED REFRIGERATION SYSTEM REPAIRS; IMPORTANT; Accurate refrigerant charge measuring device such; EQUIPMENT MUST BE CAPABLE OF:; system simultaneously.; Refrigerant Charging
  • Page 39 – BURN HAZARD; Method Of Charging / Repairs
  • Page 41 – Restricted Refrigerant System
  • Page 42 – METERING DEVICE; Capillary Tube Systems; HERMETIC COMPONENTS CHECK; CHECK VALVE; CHECK VALVE OPERATION
  • Page 43 – REVERSING VALVE DESCRIPTION/OPERATION
  • Page 44 – Reversing Valve in Heating Mode; TESTING THE REVERSING VALVE
  • Page 45 – Procedure For Changing Reversing Valve; Touch Test in Heating/Cooling Cycle; EXPLOSION HAZARD
  • Page 46 – Single Phase Connections; COMPRESSOR CHECKS; Checking the Overloads; External Overloads; Overloads; Failure to follow this warning could result
  • Page 47 – Single Phase Resistance Test; GROUND TEST
  • Page 48 – PROPER HANDLING OF; COMPRESSOR REPLACEMENT
  • Page 50 – ROUTINE MAINTENANCE; COILS AND BASE PAN; EXCESSIVE WEIGHT HAZARD
  • Page 51 – DECORATIVE FRONT COVER; thoroughly before reinstalling it in the chassis.; CLEARANCES
  • Page 52 – Removing filter
  • Page 53 – NOTE: This is a warm weather appliance; After Maintenance/Repair; Heat pumps operate differently
  • Page 54 – Service and Assistance; If you require further assistance; Available Accessories; Carbon Filter Kits; Window Installation Kits (Standard in Kühl
  • Page 55 – How to Check the Diagnostic Codes
  • Page 56 – ERROR CODES AND ALARM STATUS
  • Page 57 – Test Mode
  • Page 60 – Unit does not operate.; TROUBLESHOOTING TIPS; alerts and their history.
  • Page 62 – COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS; Possible Solution
  • Page 66 – HEAT / COOL ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS
  • Page 67 – REFRIGERANT SYSTEM DIAGNOSIS - COOLING CYCLE; HEAT PUMP ROOM AIR CONDITIONERS: TROUBLE SHOOTING TIPS
  • Page 68 – SYSTEM COOLS WHEN; HEAT PUMP; YES; REFRIGERANT SYSTEM DIAGNOSIS - HEATING CYCLE
  • Page 69 – POSSIBLE CAUSES; TROUBLESHOOTING TOUCH TEST CHART: TO SERVICE REVERSING VALVES
  • Page 70 – ELECTRONIC CONTROL BOARD COMPONENTS IDENTIFICATION
  • Page 71 – Kühl E-Control Service Kit; Configuration Instructions – Electronic Control Gen. 2; FRIEDRICH ELECTRONIC CONTROL KIT PART #
  • Page 72 – L E G E N D; Make sure you have; configuration
  • Page 76 – WIRING DIAGRAM
  • Page 81 – Replacement Remote Control Configuration Instructions; For Use with Kühl; Remote Control with Holder; ATTENTION! – If the Remote Control Does not Control the Unit,; Follow the steps below to configure:; already configured for your unit model type.; POWER; key once to illuminate the Air Conditioning Unit’s display.; and the; FAN SPEED; Keys simultaneously for approximately 6 seconds until; Air Conditioner Message; Kühl Gen2 Remote Control
  • Page 83 – Kühl User Interface Service Kit; Replacement Instructions; Mounting screws
  • Page 92 – Addendum 1; Schedule Table with Energy Saving Values
  • Page 93 – FIRST YEAR
  • Page 94 – FRIEDRICH AIR CONDITIONING CO.; TECHNICAL SUPPORT; FRIEDRICH AUTHORIZED PARTS DEPOTS; 7-01 Brooklyn Queens Expway; CUSTOMER SATISFACTION and QUALITY ASSURANCE
Loading the manual

Se

rv

ic

e M

anua

l

Standard Chassis Models

Room Air Conditioners

115-Volt:

208-230-Volt:

Cool Only
SS08M10, SS10M10, SS12M10, SS14M10
SS12M30, SS15M30, SM18M30, SM21M30

Cool with Electric Heat

208-230-Volt:

Heat Pump with Electric Heat

208-230-Volt:

Heat Pump

115-Volt:

SYSTEM

FAN MODE

SCHEDULE

FAN SPEED

AUTO

AUTO

AUTO
CONTINUOUS

°F °C

Se

rv

ic

e

M

anu

al

Standard Chassis Models

Room Air Conditioners

Cool

Electric Heat

Heat Pump

115-Volt:

208-230-Volt:

Cool Only
SS08N10*, SS10N10*, SS12N10*, SS14N10*, SM15N10*
SS12N30*, SS15N30*, SM18N30*, SM21N30*

SM24N30*,SL22N30*, SL24N30*, SL28N30*, SL36N30*

Cool with Electric Heat

208-230-Volt: ES12N33*, ES15N33*, EM18N34*, EM24N34*, EL36N35*

Heat Pump with Electric Heat

208-230-Volt: YS12N33*, YM18N34*, YL24N35*

Heat Pump

115-Volt: YS10N10*

Kuhl-Serv/PartsMan (

9

-12)

*Last character may vary

20

12 S

er

vi

ce

/P

ar

ts M

anua

l

FAN SPEED

SCHEDULE

SYSTEM

FAN MODE

POWER

F

AUTO FAN

AUTO

CONTINUOUS

C

93001402_00

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Table Of Contents

1 Table Of Contents Important Safety Information ..................................................................................................................................... 2-4 Introduction .......................................................................................................

Page 3 - IMPORTANT SAFETY INFORMATION; PERSONAL INJURY OR DEATH HAZARDS; Your safety and the safety of others are very important.; WARNING; NOTICE

2 IMPORTANT SAFETY INFORMATION The information contained in this manual is intended for use by a qualified service technician who is familiar with the safety procedures required for installation and repair, and who is equipped with the proper tools and test instruments required to service this produ...

Page 4 - REFRIGERATION SYSTEM REPAIR HAZARDS:

3 • Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, and sleeve on the room side of the air conditioning unit while cleaning. • Electrical component malfunction caused by water could result in electric shock or other electrically unsafe condi...

Other Friedrich Models

All Friedrich Other