Page 3 - to help you achieve success.; Model Number Code
2 920-087-02 (9-03) 3 920-087-02 (9-03) Announcing the Friedrich P-Series Packaged Terminal Air Conditioner. A new approach to reliability and efficiency. A totally redesigned Friedrich PTAC. Thank you for your decision to purchase the newly designed Friedrich Packaged Terminal Air Conditioner (PTAC...
Page 4 - PTAC Installation Recommendations; Figure 2
4 920-087-02 (9-03) 5 920-087-02 (9-03) PTAC Installation Recommendations For proper PTAC unit performance and maximum operating life please refer to the minimum installation clearances below: The above suggestions are for reference only and do not represent all possible installations. Please contac...
Page 5 - Installation Instructions PXDR10 Drain Kit; Internal Drain (optional for new construction); Drain Kit Location and Installation; Figure 3
4 920-087-02 (9-03) 5 920-087-02 (9-03) Installation Instructions PXDR10 Drain Kit Internal Drain (optional for new construction) NOTE: If installing an internal drain, you MUST install a drain kit on the wall sleeve before the wall sleeve is installed. 1. Refer to Figure 3 below and locate the drai...
Page 6 - External Drain (for new construction or unit replacement); Drain Kit Installation; Figure 4; Drain Tube Installation; DETAIL A
6 920-087-02 (9-03) 7 920-087-02 (9-03) External Drain (for new construction or unit replacement) When using an external drain system, the condensate is removed through either of two drain holes on the back of the wall sleeve. Select the drain hole which best meets your drainage situation and instal...
Page 7 - Wall Sleeve Installation Instructions (PXWS); For Deep Wall Installation See Section II; Typical Wall Sleeve Installation; Figure 5
6 920-087-02 (9-03) 7 920-087-02 (9-03) Wall Sleeve Installation Instructions (PXWS) NOTE: Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve, chassis and accessories. If the sleeve projects more than 8" into the room, a subbase or oth...
Page 8 - Lintel Installation; Figure 7; Dimensions; Figure 6
8 920-087-02 (9-03) 9 920-087-02 (9-03) 3. Drill two 3/16" holes through each side of the sleeve approximately 4" from top and 4" from bottom of sleeve. Screw four #10 x 1" screws (included) or appropriate fasteners for your installation, through the holes in the sides of the wall sl...
Page 9 - Extension Installation; Section II — Deep Wall Installation (PXWE); Wall Sleeve Extension Sealant Locations; Figure 8
8 920-087-02 (9-03) 9 920-087-02 (9-03) If the wall is thicker than allowed in the notes in Figure 6, a sheet metal wall sleeve extension and flashing MUST be used. Installation Instructions for the PXWE – 4" Wall Sleeve Extension The following points MUST be considered when installing a wall sl...
Page 10 - Installation Instructions Model PXGA Standard Grille; Description; Standard Grille; Figure 9
10 920-087-02 (9-03) 11 920-087-02 (9-03) Plastic handles Plastic grommets 1. Remove the center support and weatherboard if still installed in the sleeve. 2. Insert six plastic grommets into the grille openings from the outside of the grille as shown in Figure 9. 3. Insert two #8 x 3/8" sheet me...
Page 12 - Section III – Chassis Installation; chassis installation
12 920-087-02 (9-03) 13 920-087-02 (9-03) Wall sleeve Weatherboard Center support Section III – Chassis Installation 1. Remove the weatherboard and center support from the sleeve (if still in place). Be sure an outdoor grille is attached. * Check to be sure the wall sleeve, extension (if used), gril...
Page 14 - C. Standard Unit Operation; Rotary Switch Operation; D. Temperature Limiting Thermostat
14 920-087-02 (9-03) 15 920-087-02 (9-03) C. Standard Unit Operation Rotate the temperature dial in small increments in the warmer or cooler direction. Moving the dial more than 1/4" at a time may overcompensate and result in an extreme hot or cold situation. • If a remote thermostat is installe...
Page 16 - H. Air Discharge Grille; NOTE: It is highly recommended that a maintenance
16 920-087-02 (9-03) 17 920-087-02 (9-03) H. Air Discharge Grille The air discharge grille can be redirected to blow air either straight up or at an angle into the room. To change the airflow direction, remove the front cover, locate and remove the six grill retaining screws. Reverse the ends of the...
Page 17 - Remote Thermostat Selection & Wiring Guidelines for; Unit Terminal Board; Simplified Wiring Example; systems will meet this requirement.; Honeywell Thermostat Terminal Designation:; Appendix A: Remote Thermostat Unit Installation; TERMINAL LETTER; Manual Changeover Thermostat; For Heat Pump equipped units:
16 920-087-02 (9-03) 17 920-087-02 (9-03) Typical PTAC/PTHP unit Used for PTHP only Wall thermostat NOTE: It is the installer's responsibility to ensure that all control wiring connections are made in accordance with the installation instructions. Improper connection of the thermostat control wiring...
Page 18 - Remote Thermostat Installation; Terminal Strip Location
18 920-087-02 (9-03) 19 920-087-02 (9-03) Appendix A (continued) The simplified connection diagram at left shows the factory configured wiring set for 240V operation. If you are going to use 208V exclusively, switch the two (2) black wires on the 240V post of the primary side of the transformer to t...
Page 19 - Appendix B: Electrical Wiring for 265 Volt Models; Line Voltage Connections
18 920-087-02 (9-03) 19 920-087-02 (9-03) Appendix B: Electrical Wiring for 265 Volt Models 1. Remove the four control box retaining screws (A) and open the control box. 2. Pull the chassis power lead wires (B) (located on the bottom- right side of the control box) through the plastic bushing so the...
Page 20 - J. Routine Maintenance
20 920-087-02 (9-03) 21 920-087-02 (9-03) J. Routine Maintenance 1. Clean the unit air intake filter at least every 300 to 350 hours of operation. Clean the filters with a mild detergent in warm water and allow to dry thoroughly before reinstalling. 2. The indoor coil (evaporator coil), the outdoor ...
Page 21 - K. Basic Troubleshooting Techniques; Maintenance and Inspection Troubleshooting Guide; CAUSE; Environmental Effects - Cooling Mode
20 920-087-02 (9-03) 21 920-087-02 (9-03) K. Basic Troubleshooting Techniques Being familiar with the sequence of operation on Standard Controlled Operating Units or the operation of the Remote Thermostat Controlled Units is important. The following questions and answers may help to identify perform...
Page 22 - Friedrich PTAC Accessories; MODEL NUMBER DESCRIPTION PHOTO
22 920-087-02 (9-03) 23 920-087-02 (9-03) DESK CONTROL KIT A field installed kit which allows the unit to be turned on or off from a remote central station via a 24V interface. PXDC RT2 DIGITAL REMOTE THERMOSTAT A Honeywell wall mounted remote thermostat. Requires proper P-Series chassis. RT2 NEW CO...
Page 23 - MODEL NUMBER DESCRIPTION PHOTO
22 920-087-02 (9-03) 23 920-087-02 (9-03) Friedrich PTAC Accessories (continued) PXSE SLEEVE EXTENSION RETROFIT KIT G-90 zinc coated steel, 2.4" sleeve extension attached to the room side of the sleeve to allow for the installation of a P-Series Friedrich PTAC in a T-Series sleeve. PXDA LATERAL ...
Page 24 - FRIEDRICH WALLMASTER
SAVE THIS CERTIFICATE. It gives you specific rights, you may also have other rights which may vary from state to state and province to province. In the event that your unit needs servicing, contact your nearest authorized service center. If you do not know the nearest service center, ask the company...