Friedrich HEAT PUMPS - Manual

Friedrich HEAT PUMPS

Friedrich HEAT PUMPS – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 3 – Model Number Code
  • Page 4 – PTAC Installation Recommendations; Figure 2; For PTACs on the ground; • For minor obstructions
  • Page 5 – Friedrich Digital Control Features
  • Page 6 – Friedrich Digital Control Features Continued
  • Page 7 – Installation Instructions PXDR10 Drain Kit; Internal Drain (optional for new construction); Drain Kit Location and Installation; Figure 3
  • Page 8 – External Drain (for new construction or unit re place ment); Drain Kit Installation; Figure 4; Drain Tube Installation; Cover Plate Installation; DETAIL A
  • Page 9 – Wall Sleeve Installation Instructions (PDXWS); For Deep Wall Installation See Section II; Typical Wall Sleeve In stal la tion; Figure 5; locations above must be followed to ensure proper connections.
  • Page 10 – Figure 7; Dimensions; Figure 6; Lintel In stal la tion
  • Page 11 – Extension Installation; Section II — Deep Wall Installation (PXWE); Figure 8; Wall Sleeve Extension Sealant Locations
  • Page 12 – Installation Instructions Model PXGA Standard Grille; Description; Standard Grille; Figure 9
  • Page 13 – A. Electrical Rating Tables; 0A LCDI Device
  • Page 14 – Section III – Chassis Installation; Installation Checklist
  • Page 16 – Dip Switch Setting; Factory Dip Switch Con
  • Page 17 – Digital Control Operation; Temperature Display; ‘Low Fan’; Cooling Mode; Emergency Heat Operation; Fan Mode; Fan Only; Digital Control Panel
  • Page 18 – Remote Thermostat and Low Voltage Control Connections; Thermostat Connections; Remote Thermostat; Control board with optional PDXRT escutcheon kit installed
  • Page 19 – G. Fresh Air Vent Con trol; Auxiliary Fan Control; Desk Control Terminals; Maximum Wire Length for Desk Control Switch; H. Air Discharge Grille
  • Page 20 – NOTE: It is highly recommended that a maintenance
  • Page 21 – Appendix A: Electrical Wiring for 265 Volt Models; Line Voltage Connections
  • Page 22 – J. Routine Maintenance; Components
  • Page 23 – K. Basic Troubleshooting Techniques; Maintenance and Inspection Troubleshooting Guide; CAUSE; Environmental Effects - Cooling Mode; Environmental Effects - Heating Mode
  • Page 24 – Diagnostics; Error; Test Mode; Digital Control Diagnostics and Test Mode
  • Page 25 – Friedrich PTAC Accessories
  • Page 26 – PXSE
  • Page 27 – PACKAGED TERMINAL AIR CONDITIONERS
Loading the manual

920-087-04 (10-06)

PTAC
PACKAGED TERMINAL

AIR CON DI TION ERS

& HEAT PUMPS

Standard Control

Remote Thermostat

Seacoast Protected

INSTALLATION &

OPERATION GUIDE

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Model Number Code

3 920-087-04 Thank you for your decision to purchase the newly designed Friedrich Packaged Terminal Air Conditioner (PTAC). We are confi dent that you will fi nd this unit a quiet and effi cient example of Friedrich reliability. This Installation and Operation Manual has been designed to insure maxi...

Page 4 - PTAC Installation Recommendations; Figure 2; For PTACs on the ground; • For minor obstructions

4 920-087-04 PTAC Installation Recommendations For proper PTAC unit performance and maximum operating life please refer to the minimum installation clearances below: The above suggestions are for reference only and do not represent all possible installations. Please contact the factory for informati...

Page 5 - Friedrich Digital Control Features

5 920-087-04 Friedrich Digital Control Features The new Friedrich digital PTAC has state of the art features to improve guest comfort, indoor air quality and conserve energy. Through the use of specifi cally designed control software for the PTAC industry Friedrich has accomplished what other Manufa...

Other Friedrich Models

All Friedrich Other