Friedrich EQ08M11 - Manual

Friedrich EQ08M11

Friedrich EQ08M11 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
Page: / 47

Table of Contents:

  • Page 2 – Table Of Contents
  • Page 3 – IMPORTANT SAFETY INFORMATION; PERSONAL INJURY OR DEATH HAZARDS; Your safety and the safety of others are very important.; WARNING; NOTICE
  • Page 4 – REFRIGERATION SYSTEM HAZARDS:
  • Page 5 – PROPERTY DAMAGE HAZARDS; Connect to a properly grounded outlet only.; WATER DAMAGE HAZARDS:; can result in water damage to personal items or property.; INTRODUCTION; IMPORTANT
  • Page 6 – Model Number Code; RAC Serial Number Identifi cation Guide; UNIT IDENTIFICATION
  • Page 7 – PERFORMANCE DATA; Installation Information / Sleeve Dimensions; Window Mounting Kits
  • Page 8 – ELECTRICAL DATA; ELECTRIC SHOCK HAZARD; FIRE HAZARD; *HACR: Heating Air Conditioning and Refrigeration
  • Page 10 – How to operate the Friedrich room air conditioner; Figure 5; Figure 3
  • Page 11 – How to use the remote control; How To Operate The EQ08; Function Control Knob
  • Page 12 – ELECTRONIC CONTROL SEQUENCE OF OPERATION
  • Page 13 – FUNCTIONAL COMPONENT DEFINITIONS
  • Page 14 – COMPONENTS TESTING
  • Page 15 – TEST; Remove wires from thermostat; THERMOSTAT ADJUSTMENT; EQ08 SYSTEM CONTROL SWITCH - TEST; “EQ08” SYSTEM CONTROL SWITCH – TEST
  • Page 16 – CAPACITORS; Capacitor Check with Capacitor Analyzer; the test switch is released.; Capacitor Connections; identifi ed terminal is; FAN MOTOR
  • Page 17 – Should the fan motor fail or; TESTING THE HEATING ELEMENT
  • Page 18 – REFRIGERATION SEQUENCE OF OPERATION
  • Page 19 – R-410A SEALED SYSTEM REPAIR CONSIDERATIONS; Refrigeration system under high pressure
  • Page 20 – HIGH PRESSURE HAZARD; RISK OF ELECTRIC SHOCK; R-410A SEALED REFRIGERATION SYSTEM REPAIRS; Refrigerant Charging
  • Page 21 – BURN HAZARD; Method Of Charging / Repairs
  • Page 23 – Restricted Refrigerant System
  • Page 24 – Single Phase Connections; COMPRESSOR CHECKS; Exter nal Overload; With power off, remove the leads from compressor termi-
  • Page 25 – Single Phase Resistance Test; GROUND TEST
  • Page 26 – PROPER HANDLING OF; a fi nal vacuum of 200 microns or less. The system; COMPRESSOR REPLACEMENT; If any evidence of a burnout is found, no matter how
  • Page 27 – EXPLOSION HAZARD; NEVER
  • Page 28 – ROUTINE MAINTENANCE; AIR FILTER; EXCESSIVE WEIGHT HAZARD
  • Page 30 – ROOM AIR CONDITIONER UNIT; COMPRESSOR
  • Page 31 – Unit does not operate.; GENERAL TROUBLESHOOTING TIPS
  • Page 33 – COOLING ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS
  • Page 37 – HEAT / COOL ONLY ROOM AIR CONDITIONERS: TROUBLESHOOTING TIPS
  • Page 38 – ELECTRONIC CONTROL; Last character may vary.
  • Page 40 – only the exposure with the largest load.; Multiply the total square feet of; all; windows in the room by the applicable factor.; in use; Total the loads estimated for the foregoing 8 items.
  • Page 41 – COOLING LOAD ESTIMATE FORM; HEAT GAIN FROM
  • Page 42 – Following is an example using the heat load form:; The graph shows the following:; HEAT LOAD FORM
  • Page 43 – CEILING
  • Page 44 – FIRST YEAR
  • Page 45 – FRIEDRICH AIR CONDITIONING CO.
Loading the manual

Service Manual

R-410A Models

Room Air Conditioners

2 0 1 1

Cool Only

Cool with Electric Heat

X-Star-ServMan (1-11)

115-Volt: XQ05M10

*

, XQ06M10

*

, XQ08M10

*

, XQ10M10

*

115-Volt: EQ08M11

*

*

Last character may vary.

M oney

Fan

Set Hr.

Stop

Start

Tem per

ature

Fan

Cool

O n/

Cooler

W arm e

r

O nly

Speed

Saver

®

Pow er

Tim er O

peratio

n

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Table Of Contents

1 Table Of Contents Important Safety Information .......................................................................................................................................... 2-4 Unit Identifi cation ..........................................................................................

Page 3 - IMPORTANT SAFETY INFORMATION; PERSONAL INJURY OR DEATH HAZARDS; Your safety and the safety of others are very important.; WARNING; NOTICE

IMPORTANT SAFETY INFORMATION The information contained in this manual is intended for use by a qualifi ed service technician who is familiar with the safety procedures required for installation and repair, and who is equipped with the proper tools and test instruments required to service this produc...

Page 4 - REFRIGERATION SYSTEM HAZARDS:

• Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, and sleeve on the room side of the air conditioning unit while cleaning. • Electrical component malfunction caused by water could result in electric shock or other electrically unsafe conditi...

Other Friedrich Models

All Friedrich Other