Fluke PN 650454 - Manual
Fluke PN 650454 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Milliamps; See Specifications for overload protection.; To return to autorange, press
- Page 3 – Warning; To avoid electric shock, do not use the Touch Hold; Bar Graph
- Page 6 – continuously. The meter beeps twice if it is in the Touch Hold
- Page 7 – the meter face down in the holster.; Maintenance; Caution
- Page 8 – Internal Fuse Test; Battery and Fuse Replacement; Note
- Page 9 – Cleaning; Item; Specifications; Accuracy specifications are given as:; Display
- Page 12 – Overload protection for all functions and ranges: 600 V.; Function
70/73 English Instruction Sheet
Page
1
®
70/73
Series III Multimeter
Instruction Sheet
W
Read First: Safety Information
To ensure that the meter is used safely, follow these instructions:
•
Never use the meter if the meter or test leads look damaged.
•
Be sure the test leads and rotary switch are in the correct
position for the desired measurement.
•
Never measure resistance in a circuit when power is applied.
•
Never touch the probes to a voltage source when the test
leads are plugged into the 10 A or 300 mA input jack.
•
To avoid damage or injury, never use the meter on circuits that
exceed 4800 volt-amps.
•
Never apply more than the rated voltage between any input
jack and earth ground.
•
Be careful when working with voltages above 60 V dc or 30 V
ac rms. Such voltages pose a shock hazard.
•
Keep your fingers behind the finger guards on the test probes
when making measurements.
Warning
To avoid false readings, which could lead to
possible electric shock or personal injury, replace
the battery as soon as the battery indicator (
N
)
appears.
Symbols
W
Read First: Safety Information
Z
Manual Range or Automatic Touch Hold
mode
T
Double Insulation
CAT II
Overvoltage Installation Category
per IEC 1010-1.
Typical CAT II locations include main wall outlets,
local appliances, and portable equipment.
PN 650454 August 1997 Rev.2, 2/98
1997, 1998 Fluke Corporation. All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
70/73 English Instruction Sheet Page 2 Input Jacks 300 mA 10A COM FUSED V ! Milliamps Amps Volts, Ohms, Diode Test Common Terminal 600V 70 70 hr2f.eps See Specifications for overload protection. Pushbutton Use the pushbutton to either select a fixed range or put the meterin the Automatic Touch Hold ...
70/73 English Instruction Sheet Page 3 Automatic Touch Hold Mode W Warning To avoid electric shock, do not use the Touch Hold to determine if a circuit with high voltage is dead.The Touch Hold mode will not capture unstable or noisy readings. The Touch Hold mode automatically captures and di...
70/73 English Instruction Sheet Page 6 Continuity Test ( R ) + _ + _ hr5f.eps If continuity exists (resistance < 210 Ω ), the beeper sounds continuously. The meter beeps twice if it is in the Touch Hold mode. Current ( ? A ) W Warning To avoid injury, do not attempt a currentmeasurement if the ...