Fisher & Paykel OR30SDBMX - Manual

Fisher & Paykel OR30SDBMX

Fisher & Paykel OR30SDBMX – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – WHAT TO DO IF YOU SMELL GAS:
  • Page 4 – INSTALLATION INSTRUCTIONS; TOOLS NEEDED FOR INSTALLATION
  • Page 5 – GENERAL INFORMATION; Electrical Requirement; ELECTRICAL GROUNDING INSTRUCTIONS; REPLACEMENT PARTS
  • Page 6 – PROXIMITY TO SIDE CABINETS; installation
  • Page 7 – GAS AND ELECTRIC CONNECTION
  • Page 8 – OVEN VENT
  • Page 11 – INSTALLING THE COOKTOP FRONT GUARD
  • Page 12 – gas connection; Explosion Hazard
  • Page 13 – LOCK; Arrow; PRESSURE REGULATOR INSTALLATION
  • Page 14 – GAS CONNECTION SPECIFICATION
  • Page 16 – SETTING THE PRESSURE REGULATOR
  • Page 17 – To set the pressure regulator
  • Page 18 – INJECTORS TABLE
  • Page 20 – SETTING THE BURNER MINIMUM OF THE COOKTOP BURNERS
  • Page 23 – ADJUSTMENT OF THE OVEN BURNER MINIMUM
  • Page 24 – electrical connection; Recommended ground method
  • Page 25 – WIRING DIAGRAM
  • Page 27 – À L’INTENTION DE L’INSTALLATEUR SEULEMENT; Veuillez vous assurer que cet appareil est bien mis à la terre.; CUISINIÈRE À GAZ; Cet appareil est réservé à l’usage résidentiel uniquement.
  • Page 28 – CELA PEUT PROVOQUER DES BLESSURES
  • Page 30 – INSTRUCTIONS D’INSTALLATION; OUTILS REQUIS POUR L’INSTALLATION
  • Page 31 – RENSEIGNEMENTS GÉNÉRAUX; INSTRUCTIONS DE MISE À LA TERRE
  • Page 32 – PROXIMITÉ DES ARMOIRES
  • Page 33 – RACCORDEMENTS ÉLECTRIQUE ET AU GAZ
  • Page 34 – ÉVENT DE FOUR
  • Page 36 – MISE À NIVEAU DE LA CUISINIÈRE
  • Page 38 – raccordement au gaz; Robinet d’arrêt manuel; Risque d’explosion
  • Page 39 – INSTALLATION DU RÉGULATEUR DE PRESSION
  • Page 40 – SPÉCIFICATION DU RACCORDEMENT AU GAZ
  • Page 41 – Raccords de tuyaux rigides
  • Page 42 – RÉGLAGE DU RÉGULATEUR DE PRESSION
  • Page 43 – Pour régler le régulateur de pression; Installation du tiroir:
  • Page 44 – TABLEAU DES INJECTEURS; PUISSANCE; GAZ NATUREL
  • Page 46 – RÉGLAGE MINIMUM DES BRÛLEURS DE LA TABLE
  • Page 49 – RÉGLAGE MINIMUM DU BRÛLEUR DU FOUR
  • Page 50 – raccordement électrique; Méthode de mise à la terre recommandée
  • Page 51 – SCHÉMA DE CÂBLAGE
Loading the manual

THIS RANGE IS FOR RESIDENTIAL USE ONLY

FOR INSTALLER ONLY

590599B 1

104419-ß2 04.14

GAS RANGE

for residential use only

Models:

OR30SDBMX

USERS OPERATING INSTRUCTIONS

IMPORTANT - PLEASE READ AND FOLLOW

Before beginning, please read these instructions completely and carefully.

Do not remove permanently affi xed labels, warnings, or plates from the product. This may
void the warranty.

Please observe all local and national codes and ordinances.

Please ensure that this product is properly grounded.

The electrical plug should always be accessible.

The installer should leave these instructions with the consumer who should retain
for local inspector’s use and for future reference.

Installation must conform with local codes or in the absence of codes, the National Fuel Gas
Code ANSI Z223.1/NFPA 54 - Iatest edition. Electrical installation must be in accordance with
the National Electrical Code, ANSI/NFPA70 - latest edition and/or local codes.
IN CANADA: Installation must be in accordance with the current CAN/CGA-B149.1 National
Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes.
Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical
Codes Part 1 and/or local codes.

INSTALLATION IN MANUFACTURED (MOBILE) HOME: The installation must conform with
the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly
the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)]
or, when such standard is not applicable, the Standard for Manufactured Home Installations,
ANSI/NCSBCS A225.1, or with local codes where applicable.

INSTALLATION IN RECREATIONAL PARK TRAILERS: The installation must conform with
state or other codes or, in the absence of such codes, with the Standard for Recreational Park
Trailers, ANSI A119.5.

Installation of any gas-fi red equipment should be made by a licensed plumber. A manual shut-
off valve must be installed in an accessible location in the gas line external to the appliance
for the purpose of turning on or shutting off gas to the appliance (In Massachusetts such shu-
toff devices should be approved by the Board of State Examiners of Plumbers & Gas Fitters).

If an external electrical source is utilized, the appliance, when installed, must be electrically
grounded in accordance with local codes or, in the absence of local codes, with the national
Electrical Code, ANSI/NFPA 70.

Some models are supplied with a protective fi lm on steel and aluminium
parts. This fi lm must be removed before installing/using the appliance.

R

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WHAT TO DO IF YOU SMELL GAS:

2 2 WARNING ! To reduce the risk of tipping the appliance, the appliance must be secured by properly installed anti-tip device packed with the appliance. • ALL RANGES CAN TIP• INJURY TO PERSONS COULD RESULT• INSTALL ANTI-TIP DEVICE PACKED WITH RANGE • SEE INSTALLATION INSTRUCTIONS – Do not store or ...

Page 4 - INSTALLATION INSTRUCTIONS; TOOLS NEEDED FOR INSTALLATION

4 4 INSTALLATION INSTRUCTIONS WARNING! THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER.Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a quali-fi ed installer, service agent, or the gas supplier. Screwdriver 2 - Wrench T-...

Page 5 - GENERAL INFORMATION; Electrical Requirement; ELECTRICAL GROUNDING INSTRUCTIONS; REPLACEMENT PARTS

5 5 GENERAL INFORMATION 1. Installation must conform with local codes or, in the absen- ce of local codes, with the National Fuel Gas Code , ANSI Z223.1/NFPA 54 - Latest Edition, CAN/CGA-B149.1 or CAN/ CGA-B149.2. 2. Installation in manufactured (mobile) home: installation must conform with the Manu...

Other Fisher & Paykel Models