Page 3 - SAVE THESE INSTRUCTIONS; Registration; Installation instructions; CONTENTS
1 IMPORTANT! SAVE THESE INSTRUCTIONS The models shown in this user guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, go to our website fisherpaykel.com or contact your local Fisher & Pa...
Page 5 - INTRODUCTION
3 Welcome to the family of Fisher & Paykel appliances. Our team has spent thousands of hours designing, engineering and testing this Integrated Rangehood to ensure you get the perfect product for your home. For more information on your product please visit fisherpaykel.com or contact our Custome...
Page 6 - SAFETY AND WARNINGS
4 SAFETY AND WARNINGS ! WARNING! 8.2 kg (HP60) 11.5 kg (HP90) Weight Hazard The appliance is heavy. Please ensure adequate care is taken when installing the appliance to prevent personal injury. The appliance must be installed onto a solid wall, stud, beam or truss. Weight of the product is 8.2 kg ...
Page 7 - IMPORTANT SAFETY INFORMATION
5 SAFETY AND WARNINGS IMPORTANT SAFETY INFORMATION READ THE ENTIRE SET OF INSTRUCTIONS BEFORE INSTALLING OR USING THIS APPLIANCE. A copy of the user guide and installation guide for this product can also be found at fisherpaykel.com. WARNING! When using this appliance always exercise basic safety pr...
Page 9 - INSTALLATION INSTRUCTIONS; Contents of packaging
7 INSTALLATION INSTRUCTIONS Contents of packaging 13 mm screw (2) Installation instructionsUser guide manual (1) 125 mm ducting adapter (1) Rangehood (1) B U I LT- I N I N T E G R AT E D R A N G E H O O D HP60IDCHX2, HP90IDCHX2, HP60IDCHX3 & HP90IDCHX3 models I N STA L L AT I O N G U I D E / ...
Page 10 - Product and cabinetry cutout dimensions
8 INSTALLATION INSTRUCTIONS J K H I G EB FC A D m ( A ) Power cord location Ducting adapter Ø L Product and cabinetry cutout dimensions HP60 HP90
Page 11 - PRODUCT DIMENSIONS
9 INSTALLATION INSTRUCTIONS HP60 HP90 PRODUCT DIMENSIONS mm mm A Overall height of product (with ducting adapter) 316 (361) 316 (361) B Overall width of product 530 830 C Overall depth of product 280 280 D Thickness of flange 2 2 E Width of chassis 492 792 F Depth of chassis 255 255 G Height of side...
Page 12 - Height of rangehood
10 INSTALLATION INSTRUCTIONS Height of rangehood MINIMUM CLEARANCES mm P Height top of cooktop to base of product Electric cooktop Gas cooktop min. 600 – max. 750 min. 650 – max. 750 Rangehood installation height above the cooktop is the user’s preference. Lower installation heights will improve the...
Page 13 - Venting requirements; Recirculating
11 INSTALLATION INSTRUCTIONS Venting requirements IMPORTANT! To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. The range hood can be installed to operate with the exh...
Page 14 - Installation; Prepare for installation
12 INSTALLATION INSTRUCTIONS Installation WARNING! z This product is heavy and requires two persons for installation. z Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards. The manufacturer is not liable for any damage caused by not f...
Page 16 - Secure rangehood while tightening the 4 brackets / clips.
14 INSTALLATION INSTRUCTIONS width depth 2.3 2.2 2.1 x4 5 Lift the rangehood and fit through the opening of the cupboard till the spring loaded brackets / clips hold the product in place. width depth 2.3 2.2 2.1 x4 6 Secure rangehood while tightening the 4 brackets / clips. width depth 2.3 2.2 2.1 x...
Page 17 - OPERATING INSTRUCTIONS; Rangehood width; Condensation can be minimised by:; Gas cooking considerations; Installing the rangehood at the maximum recommended height.
15 OPERATING INSTRUCTIONS This rangehood should be turned on for a few minutes before cooking in order to establish air currents upward through the rangehood. This will also enable hot air removal from your kitchen and keep the rangehood surface cool. When heat, smoke, moisture, grease and cooking o...
Page 18 - Filter cleaning alert
16 Touch control panel CONTROL PANEL FEATURES Filter cleaning alert Activated regularly to alert of the need to clean filters. It can be deactivated with a single press. Timer Turn the timer on. The fan operates for 5 minutes at the current speed and each descending speed before turning off. Lights ...
Page 19 - CLEANING AND MAINTENANCE; Never use abrasive or oil based cleaners.; Abrasive cleaning products.; Filter cleaning; After rinsing and drying, replace the filters
17 CLEANING AND MAINTENANCE WARNING! z Before servicing or cleaning your rangehood, switch the power off at the control panel and disconnect the power to prevent power from being switched on accidentally. z Allow the appliance to cool after the power has been turned off before servicing. z There is ...
Page 20 - Carbon filters — for use in recirculation mode
18 Removing the aluminium filters: 1 Open the glass panel. 2 Pull the relative filter catch, tilting it downwards until it disengages from the supports. 3 Reverse these instructions when refitting the filters. Note: Do NOT operate the rangehood without the filters in place. The filters help prevent ...
Page 21 - PARTS AND ACCESSORIES; ITEM; FILTER METALLIC GTCL 90
19 PARTS AND ACCESSORIES ITEM REFERENCE NUMBER Aluminium filtersFILTER METALLIC GTCL 60 792942 FILTER METALLIC GTCL 90 792943 Recirculation carbon filter x2 792481 Ducting 150 mm kit (eaves) PD-RHK150E Ducting 150 mm kit (wall) PD-RHK150W
Page 22 - SERVICE AND WARRANTY; Complete and keep for safe reference:
20 SERVICE AND WARRANTY Complete and keep for safe reference: Model Serial No. Purchase Date Purchaser Dealer Suburb Town Country For details of your manufacturer’s warranty and contacts for servicing, please refer to your separate service and warranty book provided with your rangehood.