First Alert FA148CP - Manual
First Alert FA148CP – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 4 – For Ademco Contact ID® Reporting:; SYSTEM STATUS REPORT CODES (
- Page 5 – RESTORE REPORT CODES (; NOTE
- Page 6 – Entry 2; DOWNLOAD INFORMATION (
- Page 8 – Configurable Zone Types Worksheets; RF zone normal; Entry Zone Type 90; Zone Conditions Represented
- Page 9 – *56 ZONE PROGRAMMING WORKSHEET
- Page 10 – *57 FUNCTION KEY PROGRAMMING; ZONE LISTS FOR OUTPUT DEVICES; Record desired zone numbers below, noting that a list may include; Contains These Zones...
- Page 11 – OUTPUT DEFINITIONS; 7 must be programmed with a House Code.
- Page 12 – Zone Type Definitions
- Page 13 – Schedules
- Page 14 – ALPHA VOCABULARY LIST (For Entering Zone Descriptors); Custom; Bulleted; boldface type; Italicized
- Page 15 – 800 Series Transmitter Input Loop Identification; Each of the; WIRELESS INPUT TYPES; send periodic check-in; Note; : For information on any transmitter not shown; UL NOTE; Wireless Key Predefined Default Templates
- Page 16 – SUMMARY OF CONNECTIONS
3URJUDPPLQJ*XLGH
ON
OFF
ARMED
READY
A
B
C
D
6
4
7
BYPASS
9
CHIME
#
3
STAY
5
TEST
8
CODE
0
2
AWAY
1
OFF
MAX
INSTANT
READY
FA 2 6 0
R
ARMED RE
ADY
F A 5 6 0
6
4
7
BYPASS
9
CHIME
#
3
STAY
5
TEST
8
CODE
0
2
AWAY
1
OFF
MAX
INSTANT
READY
R
AWAY
STAY
PAGE
K5305-5PRV2 10/03 Rev. A
)$&36
)$&3
6
6
H
H
F
F
X
X
U
U
L
L
W
W
\
\
6
6
\
\
V
V
W
W
H
H
P
P
V
V
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
– 4 – NOTE: Entry of a number other than one specified will give unpredictable results. For fields *43 thru *46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ✱ ] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as th...
– 5 – ✱ 65 OPEN REPORT CODE [0,0,0] See box above. Part. 1 Part. 2 Common ✱ 66 ARM AWAY/STAY RPT CODE [0,0,0,0,0,0] See box above. Away Stay Away Stay Away Stay Part. 1 Part. 2 Common ✱ 67 RF XMTR LOW BAT REPORT CODE | [00] See box on previous page. UL: must be enabled if wireless devices are used ✱...
– 6 – ✱ 92 PHONE LINE MONITOR ENABLE UL: see Inst. Instructions for requirements [0,0] 1 2 NOTE: Output Device must either be programmed to be STOPPED in field ✱ 80 or STOPPED by Code + # + 8 + output number. Entry 1: : 0 = disabled, 1-15 = 1 min - 15 min (#+10 = 10 min; #+11 = 11 min; #+12 = 12 min...