Page 4 - For Ademco Contact ID® Reporting:; SYSTEM STATUS REPORT CODES (
– 4 – NOTE: Entry of a number other than one specified will give unpredictable results. For fields *43 thru *46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ✱ ] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as th...
Page 5 - RESTORE REPORT CODES (; NOTE
– 5 – ✱ 65 OPEN REPORT CODE [0,0,0] See box above. Part. 1 Part. 2 Common ✱ 66 ARM AWAY/STAY RPT CODE [0,0,0,0,0,0] See box above. Away Stay Away Stay Away Stay Part. 1 Part. 2 Common ✱ 67 RF XMTR LOW BAT REPORT CODE | [00] See box on previous page. UL: must be enabled if wireless devices are used ✱...
Page 6 - Entry 2; DOWNLOAD INFORMATION (
– 6 – ✱ 92 PHONE LINE MONITOR ENABLE UL: see Inst. Instructions for requirements [0,0] 1 2 NOTE: Output Device must either be programmed to be STOPPED in field ✱ 80 or STOPPED by Code + # + 8 + output number. Entry 1: : 0 = disabled, 1-15 = 1 min - 15 min (#+10 = 10 min; #+11 = 11 min; #+12 = 12 min...
Page 8 - Configurable Zone Types Worksheets; RF zone normal; Entry Zone Type 90; Zone Conditions Represented
– 8 – Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182-*185. Configurable zone types 92 and 93 (FA168CPS only) can only be programmed using the downloader software. Programming Configurable Zone Type...
Page 9 - *56 ZONE PROGRAMMING WORKSHEET
– 9 – *56 ZONE PROGRAMMING WORKSHEET (FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardwire Type Rsp. Time Location 1 [09] [1] [EOL] [1] 2 [01] [1] [EOL] [1] 3 [03] [1] [EOL] [1] 4 [03] [1] [EOL] [1] 5 [03] [1] [EOL] [1] 6 [03] [1] [EOL] [1...
Page 10 - *57 FUNCTION KEY PROGRAMMING; ZONE LISTS FOR OUTPUT DEVICES; Record desired zone numbers below, noting that a list may include; Contains These Zones...
– 10 – *57 FUNCTION KEY PROGRAMMING Option Function A B C D Comments 01 Paging 02 Time Display 03 Arm AWAY 04 Arm STAY 05 Arm NIGHT-STAY 06 Step Arming 07 Device Activation Device: 08 Comm. Test 09 Macro Key 1 10 Macro Key 2 11 Macro Key 3 12 Macro Key 4 00 Emergency Keys: zone 95 zone 99 zone 96 pa...
Page 11 - OUTPUT DEFINITIONS; 7 must be programmed with a House Code.
– 11 – ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *...
Page 12 - Zone Type Definitions
– 12 – Zone Type Definitions Type 00 Zone Not Used Use this zone type if the zone is not used. Type 01 Entry/Exit Burglary #1 • Assign to zones that are used for primary entry and exit. • Provides entry delay if the control is armed in the Away or Stay modes. • No entry delay is provided when the pa...
Page 13 - Schedules
– 13 – Type 21 Arm-Away • Arms the system in Away mode when the zone is activated. • Pushbutton units send the user number to the central station when arming or disarming. • User code for button must be assigned. Type 22 Disarm • Disarms the system when the zone is activated. • User code for button ...
Page 14 - ALPHA VOCABULARY LIST (For Entering Zone Descriptors); Custom; Bulleted; boldface type; Italicized
– 14 – ALPHA VOCABULARY LIST (For Entering Zone Descriptors) 000 (Word Space) – A – • 001 AIR • 002 ALARM ∗ 004 ALLEY 005 AMBUSH • 006 AREA • 007 APARTMENT • 009 ATTIC ∗ 010 AUDIO – B – • 012 BABY ∗ • 013 BACK ∗ • 014 BAR • 016 BASEMENT ∗ • 017 BATHROOM ∗ • 018 BED • 019 BEDROOM ∗ 020 BELL • 021 BLO...
Page 15 - 800 Series Transmitter Input Loop Identification; Each of the; WIRELESS INPUT TYPES; send periodic check-in; Note; : For information on any transmitter not shown; UL NOTE; Wireless Key Predefined Default Templates
– 15 – 5800 Series Transmitter Input Loop Identification All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones). WIRELESS INPUT TYPES ...
Page 16 - SUMMARY OF CONNECTIONS
CLASS 2 PLUG-IN TRANSFORMER 16.5V A C , 25V A (e .g. 1321). (USE No . 1321CN IN CANAD A) T O 110V A C UNSWITCHED OUTLET (24HR) + THIS EQ UIPMENT SHOULD BE INST ALLED IN A CCORD ANCE WITH THE NA TIONAL FIRE PR O TECTION ASSOCIA TION'S ST AND ARD 72, CHAPTER 2 (NA TIONAL FIRE PR O TECTION ASSOCIA TI...