Selecting A Mounting locAtion
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights
of High Flow CSR Systems are:
• Twin System - 45 lbs (20.2 kg)
• Triple System - 47 lbs (21.2 kg)
• Quad System - 49 lbs (22.2 kg)
• Quad Plus System - 49 lbs (21.2 kg) + separate surge/storage tank @ 60 lbs (27.2 kg)
2. The location should allow for (See figures 1-8):
• Minimum clearance of 2
1
⁄
2
" under the cartridge(s) so it can be lowered for removal and
replacement.
• Adequate space for “in” and “out” water line connections. Be near a drain for flushing and near
a 110V outlet if the optional Everguard
™
Low Pressure Alarm is used.
• Additional mounting and floor space for the separate SR-X Feeder and surge/storage tank
†
(Quad
Plus).
operAting SpecificAtionS*
combined Model name
replacement
cartridge
flow rate
capacity
High Flow CSR Twin - MC
MC
3.3 gpm (12.5 lpm) 18,000 gal.(68,000 L)
High Flow CSR Twin - MC
2
MC
2
3.3 gpm (12.5 lpm) 18,000 gal.(68,000 L)
High Flow CSR Twin - XC
XC
3.3 gpm (12.5 lpm) 18,000 gal.(68,000 L)
High Flow CSR Twin - XC
2
XC
2
3.3 gpm (12.5 lpm) 18,000 gal.(68,000 L)
High Flow CSR Twin - 4CB5
4CB5
3.3 gpm (12.5 lpm) 12,000 gal.(45,400 L)
High Flow CSR Twin - 7CB5
7CB5
5.0 gpm (18.9 lpm) 20,000 gal.(75,700 L)
High Flow CSR Triple - MC
MC
5.0 gpm (18.9 lpm) 27,000 gal.(102,000 L)
High Flow CSR Triple - MC
2
MC
2
5.0 gpm (18.9 lpm) 27,000 gal.(102,000 L)
High Flow CSR Triple - XC
XC
5.0 gpm (18.9 lpm) 36,000 gal.(136,000 L)
High Flow CSR Triple - XC
2
XC
2
5.0 gpm (18.9 lpm) 36,000 gal.(136,000 L)
High Flow CSR Triple - 4CB5
4CB5
5.0 gpm (18.9 lpm) 18,000 gal.(68,000 L)
High Flow CSR Triple - 7CB5
7CB5
7.5 gpm (28.5 lpm) 30,000 gal.(113,550 L)
High Flow CSR Quad - MC
MC
6.6 gpm (25.2 lpm) 36,000 gal.(136,000 L)
High Flow CSR Quad - MC
2
MC
2
6.6 gpm (25.2 lpm) 36,000 gal.(136,000 L)
High Flow CSR Quad Plus - XC
XC
6.6 gpm (25.2 lpm) 48,000 gal.(181,600 L)
High Flow CSR Quad Plus - XC
2
XC
2
6.6 gpm (25.2 lpm) 48,000 gal.(181,600 L)
* For individual cartridge specifications, refer to cartridge literature.
temperature:
35-100°F (2-38°C)
pressure:
10 - 125 psi (0.7 - 8.6 bar), non-shock
For cold water use only.
inStAllAtion
1. Use the predrilled mounting holes in the manifold bracket as guides. Mark and drill anchor holes.
Mount securely. See Figures 5-8.
2. Shut off power to equipment. If system is a High Flow CSR Quad Plus (separate SR-X Feeder and
surge/storage tank
†
), proceed to step 3b.
3a. Connect outlet ports of High Flow system to equipment served per the instructions below. Always
use NSF approved pipe dope or Teflon tape at all connections. Use a backup wrench on all fittings
while connecting to avoid stress on the system components.
• The cross fitting before the SR-X Feeder has a threaded outlet on top. Connect a minimum 1/2"
I.D. line from this outlet to fountain beverage equipment.
• The cross fitting has a flushing valve installed on the bottom. Connect tubing to the flushing valve
and run to drain. Note: Some municipal plumbing codes and good sanitary practices require an
air gap at the drain termination point.
Figure 1 – Twin
EV3112-78 Rev E AP08
Installation and Operation Guide
High Flow CSR Filter Systems
Figure 2 – Triple
Figure 4 – Quad Plus
Figure 3 – Quad
Manufactured by Everpure
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
• Connect the outlet of the SR-X Feeder to the ice machine make-up water (not condenser water) line and coffee brewing equipment. Proceed to step 4. 3b. For High Flow CSR Quad Plus System, connect outlet to equipment served per the instructions be- low. Always use a NSF approved pipe dope or Teflon ...
cArtriDge cHAnge proceDure e-Series prefilter cartridge change 1. Shut off power to equipment. Shut off inlet water ahead of system. 2. Push red relief valve. Unscrew bowl. Remove prefilter cartridge. 3. Clean bowl with filtered water only; NO SPECIAL CLE ANERS. 4. Feel head o-ring. If dry, lubricat...
for sales, replacement components, and service, contact your everpure dealer or:everpure, llc: 1040 Muirfield Drive • Hanover Park, Illinois 60133 • 800.323.7873 in europe: Toekomstlaan 30 • B-2200 Herentals, Belguim in Japan: Hashimoto MN Bldg. 7F • 3-25-1 Hashimoto Sagamihara-Shi • Kanagawa 229-11...