Installation and Operation Guide

HFC-10 Deliming System for Ware Washing Equipment

BENEFITS

• Permanently plumbed in the hot water feed line before booster heater and

dishwasher.

• Drastically reduces maintenance teardowns due to limescale accumulation.
• Assures high efficiency of heating elements by removing limescale deposits.
• Utilizes Everpure’s proprietary foodgrade delimer ScaleKleen

— no offensive

odors, no burned skin or clothing, environmentally safe.

• High grade re-enforced nylon components forlong life.
• Extends life of equipment.

APPLICATIONS

• Flash steamers
• Conventional steamers
• Combi-ovens
• Coffee/espresso machines

DEMLIMING SCHEDULE

D i s h w a s h e r O p e r a t i o n ( H o u r s )

Water Hardness

2-8

8-14

14-20

Soft, 0-3 gpg

30 days

24 days

18 days

Moderately Hard, 3-7 gpg

24 days

18 days

12 days

Very Hard, > 15 gpg

9 days

6 days

3 days

To determine water hardness and frequency of deliming, follow instructions

on hardness test strip package and compare to hours of operation.

SPECIFICATIONS

Dimensions: 12

1

2

"L x 5

1

2

"W x 5

1

2

"D

(allow extra 4" underneath for shell removal)

Inlet connection: 1/2" MPT
Pressure (Minimum - Maximum): 10 - 125 psi (non-shock)
Maximum temperature: 160°F
Shipping weight: 5 lbs.
Operating weight: 7 lbs.

INSTALLATION

Note: System must be installed on inlet water line to equipment.

Everpurerecommends the installation of a by-pass for de-liming.
1. Turn off power to equipment and drain water from system, if necessary.
2. Provide appropriate tee connections for inlet and outlet connections. Refer to the

diagram at right.

3. Install a bypass valve (buyer provided) between the inlet and outlet connections.

Refer to the diagram at right.

4. Install ball valves to inlet and outlet connections on the HFC-10 head assembly.
NOTE: Always use a good grade of pipe dope or teflon tape on connections.
5. Make appropriate connections to ball valves.

Printed in U.S.A.

EV3095-06E AU05

Provides simple, efficient deliming of commercial ware washing

equipment, utilizing ScaleKleen™, Everpure’s proprietary scale remover.

System Part No. EV9100-91
Includes:

(1) 2.2 lb. Scalekleen package

(1) Diptube assembly

(1) Hardness Test Strip

FLOW

BALL VALVE

BYPASS VALVE

SPARE PARTS:

1. EV3095-02: Head Assembly
2. EV3095-04: Gasket
3. EV3095-03: Sump Assembly
4. EV3093-35: Dip Tube

EV3095-44: Bracket Kit (bracket, nut, mtg. screws)
EV9796-01: ScaleKleen 2.2 lb. pkg. (4 pack)
EV3024-94: Hardness Test Strip

1
2
3

4