Page 3 - Notice; Documentation
i Notice Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to determ...
Page 4 - Regulatory Compliance Information
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and ...
Page 5 - Hazardous Substances
iii Electromagnetic Compatibility (EMC) This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 60825, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, CFR 1040.10, VCCI V ‐ 3. C...
Page 6 - ѻક䇈ᯢк䰘ӊ; Supplement to Product Instructions; ᳝↦᳝ᆇ⠽䋼ܗユ
iv ѻ ѻક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 &U ⒈㘨㣃 3%% ⒈Ѡ㣃䝮 3%'( 䞥ሲ䚼ӊ (Metal Parts) h ƻ ƻ h ƻ ƻ ⬉䏃ഫ ( Circuit Modules) h ƻ ƻ h ƻ ƻ ⬉㓚ঞ⬉㓚㒘ӊ ( Cables & Cable Assemblies) h ƻ ƻ h ƻ ƻ ล᭭㘮ড়⠽䚼ӊ (Plastic and Polymeric parts...
Page 7 - The single mode interface modules use Class 1 laser transceivers.
v VCCI Notice This is a class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may a...
Page 8 - Declaration of Conformity
vi Declaration of Conformity Application of Council Directive(s): 89/336/EEC73/23/EEC Manufacturer’s Name: Enterasys Networks, Inc. Manufacturer’s Address: 50 Minuteman Road Andover, MA USA 01810 European Representative Address: Enterasys Networks, Ltd. Nexus House, New...
Page 9 - Firmware License Agreement; BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
vii Enterasys Networks, Inc. Firmware License Agreement BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc. on behalf of itself ...
Page 13 - Contents; About This Guide
xi Contents About This Guide Who Should Use This Guide ........................................................................................................................... xvUsing This Guide .........................................................................................................
Page 14 - Appendix A: Specifications and Regulatory Compliance
xii Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit ................................................... 3-26 Installing an XFP/SFP Module ............................................................................................................... 3-26Removing an XFP/SFP Modul...
Page 15 - Figures
xiii Figures 1-1 Matrix X16-C Chassis as Shipped (Front View) ................................................................................. 1-2 1-2 Matrix X16-C Chassis as Shipped (Rear View) .................................................................................. 1-3 3-1 Disassembly S...
Page 16 - Tables
xiv Tables 3-1 DC/AC Power Supply (PS1-PS6) LED Definitions ........................................................................... 3-42 3-2 Fan Tray LED Definitions ................................................................................................................. 3-44 3-3 Control...
Page 17 - Who Should Use This Guide; Elektrischer Gefahrenhinweis:; Overview
Matrix X16-C Chassis Installation Guide xv About This Guide This guide describes the Enterasys Matrix™ X16 ‐ C chassis features, options, specifications, and provides information to install the chassis in a standard 19 ‐ inch (48.26 ‐ centimeter) equipme...
Page 18 - Using the Matrix X Router Manual Set
Using the Matrix X Router Manual Set xvi About This Guide Using the Matrix X Router Manual Set Additional documents are provided to explain installation of X Router Input/Output Modules (IOMs) in the X16 ‐ C, configuration of CLI commands on the X16 ‐ C an...
Page 19 - Commonly Used Acronyms
Commonly Used Acronyms Matrix X16-C Chassis Installation Guide xvii Commonly Used Acronyms The following acronyms are used extensively throughout this guide: • IOM – Input/Output Module • FM – Fabric Module • CM – Control Module • LED – Light Emitting Diode ...
Page 21 - Figure 1
Matrix X16-C Chassis Installation Guide 1-1 1 Overview This chapter describes the following: System Description The Matrix X16 ‐ C design provides 20 slots to seat 16 Input/Output Modules (IOM), two Fabric Modules (FM), and two Control Modules (CM). ...
Page 24 - Features; Matrix
Features 1-4 Overview Features The following sections provide an overview of the system features. X16-C Input/Output Modules The Matrix X16 ‐ C supports Input/Output Modules (IOM) which perform all system packet forwarding. The X16 ‐ C provides 16 ...
Page 25 - Installing Redundant CMs into an Active Matrix X Router
Features Matrix X16-C Chassis Installation Guide 1-5 (ACLs) and, by default, is associated with the VPN Routing/Forwarding (VRF) instance that all interfaces are assigned to. Be aware of the following caveats, however, when using this interface...
Page 27 - show; Proper CM Recovery
Features Matrix X16-C Chassis Installation Guide 1-7 7. Again, you can enter the show system high ‐ availability command to verify synchronization is complete and the standby CM is up. Note in the output that the Standby Module status has c...
Page 28 - X16-C Redundant Power Supplies; Power Supply LEDs; Specifications; Power Supply Replacement
Features 1-8 Overview X16-C Redundant Power Supplies The Matrix X16 ‐ C supports up to six power supplies that install on the right side of the chassis, in slots labeled PS1 through PS6. While the chassis can operate with fewer than six...
Page 29 - Rack-Mountable Chassis; Site
Features Matrix X16-C Chassis Installation Guide 1-9 Rack-Mountable Chassis The Matrix X16 ‐ C chassis is designed to be mounted in a standard 19 ‐ inch wide (48.26 ‐ centimeter) equipment rack. You can load two chassis into a standard 7 ‐ foot hig...
Page 31 - Site and Configuration Guidelines; only
Matrix X16-C Chassis Installation Guide 2-1 2 Site and Configuration Guidelines This chapter describes the following: Site Guidelines The following guidelines must be followed when a site is selected for the Matrix X16 ‐ C. If these guidelines are not ...
Page 32 - Configuration Guidelines
Configuration Guidelines 2-2 Site and Configuration Guidelines Configuration Guidelines The Matrix X16 ‐ C provides 20 slots that accept modules. IOM (Input/Output Module) slots are numbered 1 through 8 beginning with the bottom left ‐ most slot and ...
Page 33 - Matrix X16-C Chassis Setup; Required Tools; Optional
Matrix X16-C Chassis Installation Guide 3-1 3 Matrix X16-C Chassis Setup This chapter describes the following: Required Tools Installation equipment needed includes: • Box cutter • Phillips screwdriver • Flat blade screwdriver A box cutter is required to cut the ...
Page 34 - Unpacking the Matrix X16-C Chassis; Figure 3; Figure 3
Unpacking the Matrix X16-C Chassis 3-2 Matrix X16-C Chassis Setup Unpacking the Matrix X16-C Chassis The Matrix X16 ‐ C chassis is packed and shipped on a skid. Before unpacking the chassis, examine the outside packaging for obvious damage. To unpack t...
Page 35 - Figure 3-2 Disassembly Steps 3 and 4; Figure 3-3 Disassembly Step 5
Unpacking the Matrix X16-C Chassis Matrix X16-C Chassis Installation Guide 3-3 Figure 3-2 Disassembly Steps 3 and 4 5. Open the top of the shipping bag covering the unit, then pull the bag down around the skid, as shown in Figure 3 ‐ 3 . Figure 3-3 Disassemb...
Page 36 - Figure 3-4 Disassembly Steps 6 through 8
Unpacking the Matrix X16-C Chassis 3-4 Matrix X16-C Chassis Setup Figure 3-4 Disassembly Steps 6 through 8 9. Be aware that the following peripherals ship separately: – IOMs – CMs – FMs – Fan trays – Power supplies and 20 ‐ Amp line (inlet) cords (one per power su...
Page 37 - Setting Up the Matrix X16-C Chassis; Setup Order; optional
Setting Up the Matrix X16-C Chassis Matrix X16-C Chassis Installation Guide 3-5 Setting Up the Matrix X16-C Chassis The following sections describe the procedures that must be followed to complete chassis installation. Chassis are shipped with all slots labele...
Page 38 - Installing Optional Rack Support Brackets
Setting Up the Matrix X16-C Chassis 3-6 Matrix X16-C Chassis Setup Installing Optional Rack Support Brackets Rack support brackets are shipped with the chassis to provide additional support underneath the chassis. Use of these brackets is recommended for i...
Page 39 - Figure 3-5 Installing Rack Support Brackets; Installing Optional Mid-Mount Brackets
Setting Up the Matrix X16-C Chassis Matrix X16-C Chassis Installation Guide 3-7 Figure 3-5 Installing Rack Support Brackets Installing Optional Mid-Mount Brackets You can purchase an optional mid ‐ mount bracket kit for a rack or cabinet where the standard front ‐ cha...
Page 41 - Rack Mounting the Matrix X16-C Chassis
Setting Up the Matrix X16-C Chassis Matrix X16-C Chassis Installation Guide 3-9 Rack Mounting the Matrix X16-C Chassis To rack ‐ mount the Matrix X16 ‐ C chassis, proceed as follows: 1. Lift the chassis onto the support brackets. Refer back to Figure 3 ‐ 5 . If ...
Page 42 - Figure 3-7 Rack Mounting the Matrix X16-C Chassis
Setting Up the Matrix X16-C Chassis 3-10 Matrix X16-C Chassis Setup Figure 3-7 Rack Mounting the Matrix X16-C Chassis 3. Lift the chassis onto the rack support brackets (if installed). 4. Using the 16 supplied screws, attach the chassis at the mid ‐ mounting p...
Page 43 - Figure 3-8 Rack Mounting the Mid-Mounted Chassis; Chassis Bonding and Grounding
Setting Up the Matrix X16-C Chassis Matrix X16-C Chassis Installation Guide 3-11 Figure 3-8 Rack Mounting the Mid-Mounted Chassis 5. Chassis rack mounting is now complete. Chassis Bonding and Grounding Installing the chassis as described in this chapter meets the protec...
Page 44 - Figure 3-9 Telcordia GR-1089 Grounding Hole Pattern and Cable
Setting Up the Matrix X16-C Chassis 3-12 Matrix X16-C Chassis Setup To meet these requirements, use the four tapped holes located on the rear ‐ center side of the chassis. These holes meet the hole grounding bolt pattern requirements, as shown ...
Page 45 - Attaching the Electrostatic Discharge Wrist Strap; Figure 3-10 ESD Grounding Receptacle; Installing and Removing a Power Supply
Installing and Removing a Power Supply Matrix X16-C Chassis Installation Guide 3-13 Attaching the Electrostatic Discharge Wrist Strap The Electrostatic Discharge (ESD) wrist strap must be attached before handling the power supplies, fan tray, and modules used in...
Page 46 - Power Supply Planning; outage; Installing a Power Supply; Circuit A
Installing and Removing a Power Supply 3-14 Matrix X16-C Chassis Setup Power Supply Planning Although each power supply requires its own circuit, when planning the X16 ‐ C power budget you have the option of drawing from one or more sources by eith...
Page 47 - Figure 3-13 Removing Power Supply Vent Plate
Installing and Removing a Power Supply Matrix X16-C Chassis Installation Guide 3-15 5. Remove the vent plate covering all power supply slots by loosening the top and bottom captive screws, as shown in Figure 3 ‐ 13 . Figure 3-13 Removing Power Supply Vent Plat...
Page 48 - Figure 3-14 Installing Power Supply Module; Figure 3-15 Removing Blank Coverplate from Power Supply Slot
Installing and Removing a Power Supply 3-16 Matrix X16-C Chassis Setup 8. Position the power supply with the flange and captive screw pointing up and align with the slot opening. 9. With the power supply properly inserted into the opening, carefull...
Page 49 - Removing a Power Supply; Figure 3-16 Removing the AC Inlet Power Cord
Installing and Removing a Power Supply Matrix X16-C Chassis Installation Guide 3-17 12. Replace the power supply vent plate. Removing a Power Supply To remove a power supply, proceed as follows: 1. Attach the anti ‐ static wrist strap as described in “ Attachi...
Page 50 - Installing and Removing a Fan Tray; Installing a Fan Tray
Installing and Removing a Fan Tray 3-18 Matrix X16-C Chassis Setup Installing and Removing a Fan Tray The Matrix X16 ‐ C chassis is equipped with removable fan trays that allow for easy periodic replacement if a fan fails. To install and remove a fan...
Page 51 - Figure 3-17 Removing Bottom Bezel; Figure 3-18 Installing Fan Tray
Installing and Removing a Fan Tray Matrix X16-C Chassis Installation Guide 3-19 Figure 3-17 Removing Bottom Bezel 6. Slowly slide the fan tray into the open slot at the bottom of the chassis, as shown in Figure 3 ‐ 18 , until it engages with the connec...
Page 52 - Removing a Fan Tray; Installing and Removing Modules; Installing and Removing IOMs
Installing and Removing Modules 3-20 Matrix X16-C Chassis Setup Removing a Fan Tray To remove a fan tray, proceed as follows: 1. Locate the ESD wrist strap shipped with the Matrix X16 ‐ C chassis. Attach the ESD wrist strap to your wrist and plug...
Page 53 - Figure 3-19 Installing IOMs
Installing and Removing Modules Matrix X16-C Chassis Installation Guide 3-21 4. Locate Slot #1 at the bottom left side of the chassis and insert the IOM in the guide rail of the slot, as shown in Figure 3 ‐ 19 . Gently slide the module into...
Page 54 - Figure 3-20 Engaging Ejector Handles; Figure 3-21 Removing IOM Coverplate
Installing and Removing Modules 3-22 Matrix X16-C Chassis Setup Figure 3-20 Engaging Ejector Handles 7. To install additional modules, remove the coverplates from the slots, as shown in Figure 3 ‐ 21 , and repeat earlier steps. Save coverplates for optional ...
Page 55 - Installing and Removing CMs; Figure 3-22 Installing Control Module
Installing and Removing Modules Matrix X16-C Chassis Installation Guide 3-23 Installing and Removing CMs 1. Locate the empty CM1 slot, and position the module in the guide rail at the left of the slot, as shown in Figure 3 ‐ 22 . Gently insert the ...
Page 56 - Replacing the CM Battery
Installing and Removing Modules 3-24 Matrix X16-C Chassis Setup Replacing the CM Battery If the Panasonic lithium battery on the CM is failing, the system will operate properly until a power cycle, then an error message displays (see example, below...
Page 57 - Installing and Removing FMs; Figure 3-23 Installing Fabric Module
Installing and Removing Modules Matrix X16-C Chassis Installation Guide 3-25 Installing and Removing FMs 1. Locate the empty FM1 slot and position the module in the guide rail at the left of the slot, as shown in Figure 3 ‐ 23 . Gently insert the m...
Page 58 - Installing an XFP/SFP Module
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit 3-26 Matrix X16-C Chassis Setup 4. After completing all module installation, be sure that you leave no slots uncovered. Failure to seal any empty slots with the provided coverplates may...
Page 59 - Figure 3-24 Installing XFP/SFP Optical Transceiver; Removing an XFP/SFP Module
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit Matrix X16-C Chassis Installation Guide 3-27 To install an XFP/SFP transceiver, refer to Figure 3 ‐ 24 and proceed as follows: 1. Locate the ESD wrist strap shipped with the Matrix X16 ‐ C ...
Page 60 - Connecting Fiber-Optic Cables; Figure 3-25 Attaching LC or MT-RJ Cable Connector; LC
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit 3-28 Matrix X16-C Chassis Setup Connecting Fiber-Optic Cables This section describes connecting 10 ‐ or 1 ‐ Gigabit Ethernet fiber ‐ optic segments from the network or other devices to XFP or SF...
Page 61 - Connecting to the CM COM Port; Connecting the CM COM Port to an IBM PC or Compatible Device
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit Matrix X16-C Chassis Installation Guide 3-29 3. Plug the other end of the cable into the appropriate port on the other device. Some cables may be terminated at the other end with tw...
Page 62 - Figure 3-26 Connecting an IBM PC or Compatible; Connecting the CM COM Port to a VT Series Terminal; user; Parameter
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit 3-30 Matrix X16-C Chassis Setup 5. Connect the X16 ‐ C’s power cords. Refer to “ Powering Up the Matrix X16 ‐ C Chassis ” on page 3 ‐ 41. Figure 3-26 Connecting an IBM PC or Compatible Connecting the CM ...
Page 63 - Figure 3-27 Connecting a VT Series Terminal; Connecting the CM COM Port to a Modem
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit Matrix X16-C Chassis Installation Guide 3-31 Figure 3-27 Connecting a VT Series Terminal Connecting the CM COM Port to a Modem To connect a modem to the CM COM port ( Figure 3 ‐ 28 ), use a UTP cable wit...
Page 64 - Figure 3-28 Connecting to a Modem; Adapter Wiring and Signal Assignments; COM Port Adapter Wiring and Signal Diagram
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit 3-32 Matrix X16-C Chassis Setup Figure 3-28 Connecting to a Modem Adapter Wiring and Signal Assignments 1 UTP cable with RJ45 connectors 4 Local modem 2 RJ45 COM port 5 Remote modem 3 RJ45-to-DB25 modem adapter 6 IBM PC or compatib...
Page 65 - Connecting to the CM USB Port; Modem Port Adapter Wiring and Signal Diagram
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit Matrix X16-C Chassis Installation Guide 3-33 Connecting to the CM USB Port The X16 ‐ C supports fast and easy configuration downloads using the CM USB port. Using either a USB storage device (a...
Page 66 - Figure 3-29 Attaching a USB Device to the CM; Installing a Compact Flash Card; Figure 3-30 Installing Flash Card
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit 3-34 Matrix X16-C Chassis Setup Figure 3-29 Attaching a USB Device to the CM Installing a Compact Flash Card The Control Module provides an IDE port housing a 1 GB Flash memory card, as shown in Fi...
Page 67 - Installing the Memory Upgrade Kit; Removing the DIMMs; Figure 3-31 Locating the DIMMs on the CM
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit Matrix X16-C Chassis Installation Guide 3-35 Installing the Memory Upgrade Kit The following sections describe how to upgrade the Dual In ‐ line Memory Modules (DIMMs) on the X ‐ CM ‐ 00 Control Mo...
Page 68 - Figure 3-32 Removing the Existing DIMM; Installing the DIMMs
Attaching Cables, Installing Compact Flash Card and DIMM Upgrade Kit 3-36 Matrix X16-C Chassis Setup 4. Push the connector arms away from the first DIMM, as shown in Figure 3 ‐ 32 , and remove the DIMM. Figure 3-32 Removing the Existing DIMM 5. Repeat step 4 to ...
Page 69 - Optional Cable Management Kit
Optional Cable Management Kit Matrix X16-C Chassis Installation Guide 3-37 Optional Cable Management Kit Cables can be kept neat and secure using the optional Cable Management Kit (X16 ‐ CBLMG ‐ KIT). Using the Cable Management Kit ensures that cables are ...
Page 70 - Installing the Optional Cable Management Kit
Optional Cable Management Kit 3-38 Matrix X16-C Chassis Setup Installing the Optional Cable Management Kit To install the Cable Management Kit, proceed as follows: 1. Unpack the top and bottom cable management assemblies from the shipping box. Examine each ...
Page 71 - Figure 3-33 Installing the Bottom Cable Management Assembly
Optional Cable Management Kit Matrix X16-C Chassis Installation Guide 3-39 Figure 3-33 Installing the Bottom Cable Management Assembly 4. Remove the bar of the cable management assembly by loosening the two captive screws on the bar. See Figure 3 ‐ 34 on page ...
Page 72 - Figure 3-34 Securing Cables Using Velcro Cable Straps
Optional Cable Management Kit 3-40 Matrix X16-C Chassis Setup Figure 3-34 Securing Cables Using Velcro Cable Straps 1 Bottom cable management assembly base panel 2 Captive screws (2) on base panel 3 Velcro cable straps (8 attached to each cable management assembly base panel) 4 Cables 5 Bar (attache...
Page 73 - Powering Up the Matrix X16-C Chassis; Figure 3-35 Connecting 20 Amp AC Power Cord to the Power Supply; Table A
Powering Up the Matrix X16-C Chassis Matrix X16-C Chassis Installation Guide 3-41 Powering Up the Matrix X16-C Chassis To power up the Matrix X16 ‐ C chassis, proceed as follows: 1. Plug one end of each power cord (included with the power supply) into the ...
Page 74 - LEDs and Reset Button; Figure 3-36 Power Supply LEDs; Function
LEDs and Reset Button 3-42 Matrix X16-C Chassis Setup LEDs and Reset Button The following sections describe LED indications for the following: • Power supplies and fan trays • IOM, CM, and FMs (with CM Reset button) Power Supply LEDs Two LEDs are provided ...
Page 75 - Fan Tray LEDs; Figure 3-37 Fan Tray LED
LEDs and Reset Button Matrix X16-C Chassis Installation Guide 3-43 Fan Tray LEDs Each fan tray provides a status LED on its front panel. Fan tray LEDs are provided on the chassis bezels (only bottom LEDs shown) and on the optional cable manag...
Page 76 - Module LEDs and Reset Button; Control and Fabric Module LEDs; Table 3-2 Fan Tray LED Definitions
LEDs and Reset Button 3-44 Matrix X16-C Chassis Setup Figure 3-39 Fan Tray LEDs on Bottom Cable Management Assembly Base Panel The following additional conditions apply: • After power up, the fan tray LED remains red until diagnostics begin, then will blink gree...
Page 77 - Figure 3-40 Fabric and Control Module LEDs and Reset Button; Table 3-3 Control and Fabric Module LED Definitions
LEDs and Reset Button Matrix X16-C Chassis Installation Guide 3-45 Figure 3-40 Fabric and Control Module LEDs and Reset Button 1 STATUS LEDs 3 RESET button 5 Link LED 2 ACTIVE/STANDBY LEDs 4 10/100/1000 LED STATUS ACTIVE/ STANDBY RESET ETHERNET STATUS ACTIVE/STANDBY 12 123 4 5 Fabric Module Control ...
Page 78 - IOM LEDs; Table 3; Table 3-4 IOM LED Definitions; Status LED
LEDs and Reset Button 3-46 Matrix X16-C Chassis Setup The following additional conditions apply: • After module power up, the CM/FM STATUS LED will remain red until diagnostics begin then will blink green. • After module power up, the ACTIVE/STANDB...
Page 79 - First-Time Quick Configuration; Assigning an IP Address to eth0
First-Time Quick Configuration Matrix X16-C Chassis Installation Guide 3-47 First-Time Quick Configuration This section describes the minimal configuration required to facilitate first ‐ time communications with the Matrix X16 ‐ C. Consider the following: • Decide ...
Page 80 - Enabling NTP
First-Time Quick Configuration 3-48 Matrix X16-C Chassis Setup Enabling NTP To configure NTP for the Matrix X16 ‐ C, enter the following commands at the CLI prompt. The following commands enable the Matrix X16 ‐ C either as an NTP client or ser...
Page 81 - Specifications and Regulatory Compliance; Item
Matrix X16-C Chassis Installation Guide A-1 A Specifications and Regulatory Compliance This appendix provides information about the following: Enterasys Networks reserves the right to change specifications at any time without notice. Chassis, Power Supply, and Fan T...
Page 82 - Table A-2 AC Power Supply Requirements
Power Supply Requirements, Specifications, and Twist Lock Options A-2 Specifications and Regulatory Compliance Power Supply Requirements, Specifications, and Twist Lock Options The requirements for Matrix X Router AC power supply modules are shown in Table A ‐ 2 : The pow...
Page 83 - Table A-3 Module Power Specifications; Table A-4 Redundancy Configurations for AC Line 100–120 Vac
Power Supply Requirements, Specifications, and Twist Lock Options Matrix X16-C Chassis Installation Guide A-3 Table A-3 Module Power Specifications Module @ 110 Vac / 220 Vac Power (Watts) Thermal Output (BTU/HR) CM 97 Watts 331.1 BTU/HR Fan tray 85 Watts 290.1 BTU/HR X4-FM 30 Watts 102.4 BTU/HR X8-...
Page 84 - Table A-6 Twist Lock Power Cord Options
10-Gigabit Ethernet Transceiver Specifications (XFP) A-4 Specifications and Regulatory Compliance Matrix X16 ‐ C twist lock power cord options are as follows: 10-Gigabit Ethernet Transceiver Specifications (XFP) The 10 ‐ Gigabit XFP (10 ‐ Gigabit Small Form Factor Plu...
Page 85 - Table A-9 Recommended Cable Types and Specifications
1-Gigabit Ethernet Transceiver Specifications (SFP) Matrix X16-C Chassis Installation Guide A-5 The following XFP specifications in Table A ‐ 9 meet or exceed the IEEE 802.3ae ‐ 2002 standard. 1-Gigabit Ethernet Transceiver Specifications (SFP) The following Small Form ...
Page 86 - SFP Input/Output Specifications
SFP Input/Output Specifications A-6 Specifications and Regulatory Compliance SFP Input/Output Specifications Matrix X Router Ethernet port interfaces accept 1000BASE ‐ SX short wavelength or 1000BASE ‐ LX long wavelength fiber SFPs (see Table A ‐ 10 ) and are ...
Page 87 - Table A-13 MGBIC-LC03 Optical Specifications
SFP Input/Output Specifications Matrix X16-C Chassis Installation Guide A-7 MGBIC-LC03 Specifications (1000BASE-SX) MGBIC-LC09 Specifications (1000BASE-LX) Table A-13 MGBIC-LC03 Optical Specifications Item 62.5/125 µm MMF 50/125 µm MMF Transmit Power (minimum) -9.5 dBm -9.5 dBm Transmit Power (maxim...
Page 88 - Table A-17 MGBIC-08 Optical Specifications
SFP Input/Output Specifications A-8 Specifications and Regulatory Compliance MGBIC-08 Specifications (1000BASE-ELX) MGBIC-02 Specifications (1000BASE-T) Table A-17 MGBIC-08 Optical Specifications Item 62.5 µm MMF 50 µm MMF 10 µm SMF Transmit Power (minimum) -0 dBm, min. +2 dBm, typical +5 dBm, max. ...
Page 89 - COM Port Pinout Assignments; Figure A; Figure A-1 COM Port Pin Assignments; Regulatory Compliance; Table A-20 COM Port Pin Assignments; Pin; Table A-21 Regulatory Requirements
COM Port Pinout Assignments Matrix X16-C Chassis Installation Guide A-9 COM Port Pinout Assignments The COM port is a serial communications port for local access to Local Management, as shown in Figure A ‐ 1 . Refer to Table A ‐ 20 for the COM port p...
Page 91 - Index; Numerics
Index-1 Index Numerics 10-Gigabit Ethernet Transceiver Specifications (XFP) A-4 1-Gigabit Ethernet Transceiver Specifications (SFP) A-5 A AC Power LED description of 3-42 location on power supply 3-42 AC1 inlet link to PS1 3-17 view of 3-17 , 3-41 ACTIVE/STANDBY LED description of 3-45 for CM and FM...