Page 3 - Notice; Documentation
i Notice Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to determ...
Page 4 - Regulatory Compliance Information
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and ...
Page 5 - Hazardous Substances
iii Electromagnetic Compatibility (EMC) This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 2006/95/EC, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3. Compatibilidad Electromágnetica ...
Page 6 - ѻક䇈ᯢк䰘ӊ; Supplement to Product Instructions; ᳝↦᳝ᆇ⠽䋼ܗユ
iv ѻ ѻક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 &U ⒈㘨㣃 3%% ⒈Ѡ㣃䝮 3%'( 䞥ሲ䚼ӊ (Metal Parts) h ƻ ƻ h ƻ ƻ ⬉䏃ഫ ( Circuit Modules) h ƻ ƻ h ƻ ƻ ⬉㓚ঞ⬉㓚㒘ӊ ( Cables & Cable Assemblies) h ƻ ƻ h ƻ ƻ ล᭭㘮ড়⠽䚼ӊ (Plastic and Polymeric parts...
Page 7 - The single mode interface modules use Class 1 laser transceivers.
v VCCI Notice This is a class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may a...
Page 8 - Declaration of Conformity
vi Declaration of Conformity Application of Council Directive(s): 2004/108/EC2006/95/EC Manufacturer ’s Name: Enterasys Networks, Inc. Manufacturer ’s Address: 50 Minuteman Road Andover, MA 01810 USA European Representative Address: Enterasys Networks, Ltd. Nexus House, N...
Page 9 - Enterasys Networks, Inc. Firmware License Agreement; BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
vii Enterasys Networks, Inc. Firmware License Agreement BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc., on behalf of its...
Page 11 - AUDIT
ix 8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys, and, accordingly, You hereby agree to maintain complete books, records and accounts showing ...
Page 13 - Contents; Chapter 1: DC Power Supply Installation
xi Contents Chapter 1: DC Power Supply Installation Overview of the DC Power Supply ..................................................................................................... 1-2 Power Supply Redundancy Planning ................................................................................
Page 15 - About This Guide; Who Should Use This Guide; Elektrischer Gefahrenhinweis:
Matrix X Router DC Power Supply Installation Guide xiii About This Guide This guide describes the Enterasys Matrix ™ X Router DC power supply features and specifications, and provides information to install the power supply in an Enterasys Matrix™ ...
Page 16 - Conventions Used in This Guide
Conventions Used in This Guide xiv About This Guide Documentation can be accessed on the World Wide Web, at the following URL: http://www.enterasys.com/support/manuals/ Conventions Used in This Guide The following conventions are used in this guide: Note: Calls ...
Page 17 - Getting Help
Getting Help Matrix X Router DC Power Supply Installation Guide xv Getting Help For additional support related to the DC power supply or this document, contact Enterasys Networks using one of the following methods: Before contacting Enterasys Networks for ...
Page 19 - DC Power Supply Installation
Matrix X Router DC Power Supply Installation Guide 1-1 1 DC Power Supply Installation This chapter provides installation instructions for the Enterasys Matrix™ X Router DC power supply module (X ‐ DC). Follow the order of the sections listed below to ...
Page 20 - Overview of the DC Power Supply; Figure 1; Front View of the DC Power Supply
Overview of the DC Power Supply 1-2 DC Power Supply Installation Overview of the DC Power Supply The DC power supply (X ‐ DC) can be used in the Enterasys Matrix™ X16 ‐ C, X8 ‐ C, and X4 ‐ C chassis in place of the standard AC power supplies (X ‐ AC)...
Page 21 - Back View of the DC Power Supply
Overview of the DC Power Supply Matrix X Router DC Power Supply Installation Guide 1-3 Figure 1-2 Back View of the DC Power Supply The DC power supply provides the following features: • Input Overload Protection As shown in Figure 1 ‐ 1 on page 1 ‐ 2, the power supp...
Page 22 - Power Supply Redundancy Planning; Power; Installation Site Requirements
Installation Site Requirements 1-4 DC Power Supply Installation Power Supply Redundancy Planning Because chassis system components consume varying amounts of electrical power, Enterasys recommend consulting the module power specifications in “ Power Supply Red...
Page 23 - Pre-Installation Tasks; Verify DC Power Compliance of Matrix X Modules; Converting Existing AC-powered Matrix X Router Systems to DC; show system hardware
Pre-Installation Tasks Matrix X Router DC Power Supply Installation Guide 1-5 Pre-Installation Tasks Complete the following tasks before installing the DC power supply: • Verify DC Power Compliance of Matrix X Modules • Prepare Site Wiring for DC Power Ins...
Page 24 - Part; Serial; Table 1; Worksheet: DC Compliance of Modules in Existing AC Systems
Pre-Installation Tasks 1-6 DC Power Supply Installation 2. Use the information from the output of the show system hardware command to fill out the worksheet in Table 1 ‐ 1 for each module as follows: a. Use the value of “940 Part number:” from ...
Page 25 - New DC Power Matrix X System Installations; Worksheet: DC Compliance of Modules for New DC Systems; Front Panel Serial Number
Pre-Installation Tasks Matrix X Router DC Power Supply Installation Guide 1-7 New DC Power Matrix X System Installations If the system is a new Matrix X DC ‐ powered installation, follow this procedure to verify DC power compliance of all modules: 1. Obtain ...
Page 26 - Prepare Site Wiring for DC Power Installation; Chapter 2; DC; Model Name
Pre-Installation Tasks 1-8 DC Power Supply Installation Prepare Site Wiring for DC Power Installation 1. Ensure that a branch circuit disconnect device is installed, and that the device is switched to prevent power from being supplied to the DC power ...
Page 27 - Unpacking the DC Power Supply
Unpacking the DC Power Supply Matrix X Router DC Power Supply Installation Guide 1-9 Unpacking the DC Power Supply To unpack the DC power supply: 1. Open the box and remove the packing material protecting the DC power supply. 2. Verify the contents of the ...
Page 28 - Getting; Installing the DC Power Supply; Contents of X-DC Carton; Item
Installing the DC Power Supply 1-10 DC Power Supply Installation 3. Remove the tape seal on the non ‐ conductive bag to remove the module. 4. Perform a visual inspection of the power supply and cable harness for any signs of physical damage. Co...
Page 29 - Removing Power Supply Vent Plate
Installing the DC Power Supply Matrix X Router DC Power Supply Installation Guide 1-11 2. Remove the vent plate covering all power supply slots by loosening the top and bottom captive screws, as shown in Figure 1 ‐ 3 . Figure 1-3 Removing Power Supply Vent Pla...
Page 30 - Installing Power Supply Module
Installing the DC Power Supply 1-12 DC Power Supply Installation 5. Hold the power supply by placing one hand on the handle located on the front panel and using your other hand to support the power supply. 6. Position the power supply with ...
Page 31 - Removing Blank Coverplate from Power Supply Slot
Installing the DC Power Supply Matrix X Router DC Power Supply Installation Guide 1-13 Figure 1-5 Removing Blank Coverplate from Power Supply Slot 10. Connect the chassis to earth ground utilizing the earth ground connection on the back of the unit. a. Cut an 8 ...
Page 32 - Removing a Power Supply
Removing a Power Supply 1-14 DC Power Supply Installation b. Place the lock washers over the positive and negative studs. c. Place the nuts over the lock washers and tighten. Torque applied must be 36 in ‐ lb. 13. Replace the plastic shield. 14. Re...
Page 35 - DC Power Supply Specifications; Specifications; Table 2; Physical Specifications; Electrical Specifications
Matrix X Router DC Power Supply Installation Guide 2-1 2 DC Power Supply Specifications This chapter provides the DC power supply specifications and regulatory compliance information. Specifications Table 2 ‐ 1 lists the physical specifications. Table 2 ‐ 2 lists ...
Page 36 - Compression Lugs; Power Supply Redundancy
Power Supply Redundancy 2-2 DC Power Supply Specifications Compression Lugs The DC power supply positive and negative bolt patterns match up to a 1/4 ‐ inch diameter, 2 ‐ hole compression lug spaced 5/8 ‐ inch on center. This compression lug must t...
Page 37 - Module Power Specifications; Module; Redundancy Configurations for DC Power Supply; No. of Power Supplies
Power Supply Redundancy Matrix X Router DC Power Supply Installation Guide 2-3 Table 2-3 Module Power Specifications Module @ 48 VDC Power (Watts) Thermal Output (BTU/HR) CM 97 Watts 331.1 BTU/HR Fan tray 85 Watts 290.1 BTU/HR X4-FM 30 Watts 102.4 BTU/HR X8-FM 62 Watts 211.6 BTU/HR X16-FM 98 Watts 3...
Page 38 - Compliance Standards; Regulatory Compliance
Regulatory Compliance 2-4 DC Power Supply Specifications Regulatory Compliance The DC power supply meets the safety and electromagnetic compatibility (EMC) requirements listed in Table 2 ‐ 5 : Table 2-5 Compliance Standards Regulatory Compliance Standards Safety UL 60950,...