Model #

DC Voltage Current (continuous) Current (peak)

Current Output (maximum charge)

PCB Size

6, 12

1.5A

2.0A

6 V = 200mA, 12 V = 400mA

2

7

/

8

” x 2

1

/

4

” x 1”

(73 x 57 x 25 mm)

6, 12, 24

1.5A

2.0A

6 V = 180mA, 12 V = 350mA, 24 V = 700mA

2

7

/

8

” x 2

1

/

2

” x 1

3

/

8

(73 x 64 x 35 mm)

6, 12, 24

2.5A

3.0A

6 V = 180mA, 12 V = 350mA, 24 V = 700mA

3

3

/

8

” x 2

7

/

8

” x 1

5

/

16

(81 x 73 x 33 mm)

6, 12, 24

4.0A

5.0A

6 V = 180mA, 12 V = 350mA, 24 V = 700mA

3

3

/

4

” x 2

7

/

8

” x 1

9

/

16

(95 x 73 x 40 mm)

6, 12, 24

7.0A

7.5A

6 V = 180mA, 12 V = 350mA, 24 V = 700mA

5

1

/

2

” x 5

1

/

8

” x 2

11

/

64

(140 x 130 x 55 mm)

6, 12, 24

9.0A

10.0A

6 V = 180mA, 12 V = 350mA, 24 V = 700mA

5

1

/

2

” x 5

1

/

8

” x 2

11

/

64

(140 x 130 x 55 mm)

Note: Products with model number that ends with "Q"or have a green “Q” sticker represents RoHS compliant products.

ST-2406-2AQ shown

ENFORCER

®

Installation Manual

ST-series

Power Supplies/Chargers

Features:

• Automatic recharging of back-up batteries.
• Several models to choose from.
• Programmable DC voltage output.
• Built-in battery short-circuit protection.
• Fused output for a regulated charge.
• Automatic switch-over to the backup battery if main power is lost or cut.
• LEDs indicate power status.
• Includes foam tape and battery leads for easy installation.
• Regulated and filtered output voltage.

What it is:

SECO-LARM’s ST-series of power supplies/chargers ensure that alarm systems and access control systems always have
enough power to do their job. Protected by fused output, input polarity protection diodes, and back-up battery polarity
reverse protection, these power supplies/chargers can be used to maximize the security and efficiency of nearly any alarm
or access control installation.

Fused Output:

The ST-1206-1.5AQ comes with a 3A fuse. The ST-2406-2AQ, ST-2406-3AQ, and ST-2406-5AQ models come with a 5A
fuse. The ST-2406-7AQ and ST-2406-10AQ come with a 10A fuse. Use only the correct fuses to prevent short circuits
and damage to the power supplies/chargers or the alarm access control panel.

WARNING:

Connect these power supplies/chargers only to a rechargeable back-up battery. Use of a non-rechargeable back-up
battery could result in damage to the power supplies/chargers or the alarm access control panel, as well as leakage or
explosion of the battery.

Installation:

1. Mount the PC board in the desired location or enclosure. It must be easily accessible for future servicing.
2. DC Power Output Setting:

a. To program ST-1206-1.5AQ DC voltage output:

1. 6VDC — Cut the wire loop, and connect to a 12VAC/20VA transformer.

INSULATE THE CUT WIRE LEADS so that they do not come in contact with the power supplies/chargers.

2. 12VDC — Leave the wire loop uncut, and connect to a 16VAC/40VA transformer.

ST-1206-1.5AQ

ST-2406-2AQ

ST-2406-3AQ
ST-2406-5AQ

ST-2406-7AQ

ST-2406-10AQ

b. To program ST-2406 Series DC voltage output:

1. Set the desired DC output voltage ( 6, 12, or 24 VDC ) of the power supply using the DIP switch.

See Table 2.

2. The default voltage output setting is 12 VDC.