Enforcer SA-026 - Manual

Enforcer SA-026

Enforcer SA-026 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

The ENFORCER SA-026 is a low-voltage miniature delay timer module
which operates on 12 to 24 volts AC or DC. This timer module will extend
the activation time of a momentary contact switch for 1~60 seconds
via a field-adjustable rotary pot. It is ideal for electrical locks which do
not have a built-in time delay function. Its compact size makes it small
enough to fit in a single-gang box or inside a door frame cavity.

Adjustable timer from 1~60 seconds via a pot on board.
N.O./N.C. switch trigger.
Compact design: 1.2” X 2.28” X 0.62” (30 x 58 x 16 mm)
Operating voltage: 12~24 volts AC or DC.
Current: 2mA (stand-by), 75mA (active).
Relay output: Form-C (SPDT) via terminal blocks.
Contact rating: 2 Amps @ 24VDC.
With built-in beeper output (100mA @ 24VDC).
Includes double-sided foam tape.

1.949.261.2999 (CA & Int’l) 1.800.662.0800 Fax: 1.949.261.7326
Email: [email protected] Website: www.seco-larm.com

16842 Millikan Avenue, Irvine, CA 92606

SA-026TIMERMODULE.cdr

Mini Timer Module

Features:

The SECO-LARM policy is one of continual development. For that reason, SECO-LARM reserves the right to change prices and specifications without notice. SECO-LARM is not responsible for misprints.

Copyright 2007 SECO-LARM U.S.A., Inc. All rights reserved.

SA-026

SA-026

S

E

C

O

-L

A

R

M

®

Electrical exit

locking devices

such as magnetic locks

and electric strikes.

Beeper

Power (non polarity)

TRG.(COM)

TRG.(N.C.)

TRG.(N.O.)

-

+

To N.O. switch

To N.C. switch

Relay O/P (N.C.)

Relay O/P (N.O.)

Relay O/P(COM)

(Buzzer,

- )

(Buzzer,

)

+

To N.O. device

To N.C. device

Sample Connection Diagram:

For Fail-Safe Electronic Locks

Also available:

SD-7202GC-PT

Illuminated Push-To-Exit

Plate with Built-in Timer

SD-7201GA-PT1

Push-To-Exit Plate with

Built-in Timer

SA-025

Multi-Function

Programmable Timer

SR-2224-C5

DPST Relay Board

(Actual size)

Power (non polarity)

PUSH

TO

EXIT

12~24 volts

AC or DC

Power Supply

Trigger Devices:

Push-to-Exit

Switches,

Keypads, Control

Panels, etc.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Enforcer Models

All Enforcer Other