OPERATING THE ENFORCER 190 / 190S

MOUNTING THE DETECTOR

It therefore should be mounted in a location within which ever y glass
window and door to be protected is found. For greatest secur ity, attach to
the wall or ceiling, using screws instead of double-sided foam tape. For
larger areas, two or more units can be used without fear of interfering with
each other.

SETTING THE SENSITIVITY

The ENFORCER 190/190S includes SECO-LARM's unique patented
Yellow turbulence LED. This LED flashes when environmental noise is high
enough to cause false alar ms, thereby allowing instant sensitivity setting
without the use of a special exter nal test meter.

To set sensitivity, hold a thin flexible plastic r uler flat against a glass
window within the unit's protection range.
Pick up one end of the ruler while holding
the other end down, and then let the ruler
snap against the glass window. This
should cause the Yellow LED to come ON,
but the Red LED should not light. If the
Red LED comes ON with a slight snap, the
ENFORCER 190/190S may be too
sensitive, and the sensitivity control should
be tur ned counterclockwise with a small
flat or phillips screwdriver. If the Yellow
LED does not come ON, sensitivity should
be increased by tur ning the control clockwise. Continue snapping the ruler
on the window until the Yellow LED comes ON but the Red LED does not.
Repeat this process with each window to ensure the ENFORCER 190/
190S
is set for ever y pane of glass.

When the correct sensitivity is found using the above procedure, deter mine
whether the sensitivity is high enough to trigger the alar m by snapping the
ruler harder to simulate a break-in. If the Red LED does not come ON, the
sensitivity must be increased.

NOTE: For applications within this temperature range the sensitivity will be

stable. If the temperature should drop below -14

°

F (-10

°

C), the

sensitivity of the ENFORCER 190/190S will increase, and the
sensitivity setting will need to be decreased. If the temperature
should r ise above 122

°

F (50

°

C), the sensitivity of the

ENFORCER 190/190S will decrease, and the sensitivity setting will
need to be increased.

When setting sensitivity, make sure the room's environment is as close as
possible to what it will be when the ENFORCER 190/190S is in use. For
instance, if the cur tains are usually closed at night when the alarm is
ar med, then set sensitivity with the cur tains closed. If a window in the
room is left opened, then set the sensitivity with window open. The
sensitivity should always be retested when the environment of the room
changes, such as when fur niture is moved.

Depending on the type of glass, sensitivity is different when set by tapping

the inside or outside of the window with a ruler. For best results,
tap the inside of the window.

NOTE: DO NOT SET SENSITIVITY ANY HIGHER THAN NECESSARY TO

PROTECT THE GLASS IN THE DETECTOR'S RANGE. SETTING
SENSITIVITY HIGHER THAN NEEDED INCREASES THE
CHANCE OF FALSE ALARMS WITHOUT INCREASING
PROTECTION. LEAVING A DOOR OR WINDOW OPEN WILL
ALSO INCREASE THE CHANCE OF FALSE ALARMS.

TAMPER-PROOFING CASE

For extra protection, the ENFORCER 190/190S is equipped with an
N.C. Tamper Switch to protect against opening or breaking of the
case.

INSTALLATION

SCREW TERMINALS:

MIN

MAX

#7: N.C. TAMPER OUTPUT
#6: COMMON TAMPER OUTPUT
#5: COMMON GROUND
#4: 12VDC
#3: DRY RELAY N.O.*
#2: DRY RELAY COMMON*
#1: DRY RELAY N.C.*

* For N.O. output, use Terminals 2 and 3

For N.C. output, use Terminals 2 and 1