Empire Comfort Systems FAW-40-1SPP - Manual

Empire Comfort Systems FAW-40-1SPP

Empire Comfort Systems FAW-40-1SPP – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – THIS IS A HEATING APPLIANCE; DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANELS INSTALLED
  • Page 3 – SAFETY INFORMATION FOR USERS OF LP-GAS; Close all gas tank or cylinder supply valves.; SOME POINTS TO REMEMBER; That's your signal to go into immediate action!
  • Page 4 – — Use the free area of a louver or grill to determine the size opening
  • Page 5 – Figure 4
  • Page 7 – Figure 7; hole in the side panel.; Figure 8
  • Page 8 – Figure 9; After use, cleaning may be required for the proper flame.
  • Page 10 – SERVICE AND MAINTENANCE SUGGESTIONS; If Electrode Does Not Produce Spark:
  • Page 11 – FOR YOUR SAFETY READ BEFORE LIGHTING; causing property damage, personal injury or loss of life.; TO TURN OFF GAS TO APPLIANCE; STANDING PILOT MODEL
  • Page 12 – FOR YOUR SAFETY READ BEFORE OPERATING; OPERATING INSTRUCTIONS
  • Page 13 – SEQUENCE OF OPERATION
  • Page 14 – with the Sequence of Operation; IP SYSTEM TROUBLESHOOTING SEQUENCE; INSET A
  • Page 15 – How To Order Repair Parts; Furnace Model Number
  • Page 17 – Service Notes
  • Page 19 – RADIATEUR MURAL À; MODÈLE; — Ne pas entreposer ou employer de la gazoline ou
  • Page 20 – CECI EST UN APPAREIL DE CHAUFFAGE; Garder propre le brûleur et le compartiment de contrôle.
  • Page 21 – C’est le signal que vous devez agir immédiatement.; QUELQUES POINTS À RETENIR
  • Page 22 – ne doivent pas être plus petites que 6mm.
  • Page 24 – Figure 6; B. Du bas de l’ouverture murale au haut de l’ouverture murale, la
  • Page 26 – ANS Z21.45 Connexions flexibles d’appareil autre qu’en métal.
  • Page 27 – Le gaz propane n’exige aucun ajustement.
  • Page 28 – Utiliser une tige d’allumage pour allumer la veilleuse avec une; Si l’électrode ne produit pas d’étincelle:; ouvert (dans le sens opposé des aiguilles d’une montre pour “ouvert”).
  • Page 30 – MODÈLE DE LA VEILLEUSE FIXE
  • Page 31 – MODÈLE DE LA VEILLEUSE INTERMITTENTE (IP); POUR VOTRE SÉCURITÉ LIRE AVANT D’ALLUMER; INSTRUCTIONS DE FONCTIONNEMENT
  • Page 32 – Séquence de Fonctionnement
  • Page 33 – Guide de Détection des Défectosités pour le Système IP; Graphique A
  • Page 34 – Façon de Commander les Pièces de Réparation; Numéro du modèle du radiateur
Loading the manual

12427-2-0903

Page 1

INSTALLATION INSTRUCTIONS

AND

OWNER'S MANUAL

FAN TYPE

VENTED

WALL FURNACE

MODEL

FAW-40-1SPP

FAW-40-1IP

EFFECTIVE DATE

SEPTEMBER 2003

WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the vi-
cinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do
not use any phone in your building.

Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.

If you cannot reach your gas supplier,
call the fire department.

— Installation and service must be per-

formed by a qualified installer, service
agency or the gas supplier.

WARNING: If not installed, operated and
maintained in accordance with the manu-
facturer's instructions, this product could
expose you to substances in fuel or from
fuel combustion which can cause death or
serious illness.

Installer: Please leave these instructions with the
consumer.

Consumer: Please retain these instructions for
future use.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - THIS IS A HEATING APPLIANCE; DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANELS INSTALLED

12427-2-0903 Page 2 The base referred to above does not mean the fire-proof base as used onwood stoves. The protection is for rugs that are extremely thick and lightcolored tile. Installation in Residential GaragesGas utilization equipment in residential garages shall be installed so thatall burners...

Page 3 - SAFETY INFORMATION FOR USERS OF LP-GAS; Close all gas tank or cylinder supply valves.; SOME POINTS TO REMEMBER; That's your signal to go into immediate action!

12427-2-0903 Page 3 Some people cannot smell well. Some people cannot smellthe odor of the chemical stench put into the gas. You mustfind out if you can smell the odorant in propane. Smoking candecrease your ability to smell. Being around an odor for a timecan affect your sensitivity or ability to d...

Page 4 - — Use the free area of a louver or grill to determine the size opening

12427-2-0903 Page 4 furnace opening confinedspace Figure 1 Outdoor AirOutlet and inlet air can be brought into the confined space via openingsinto a ventilated attic and ventilated crawl space. furnace outlet air inlet air attic ventilation louvers crawl space ventilation louvers Figure 2 Confined S...