Empire Comfort Systems BF-20-2 - Manual

Empire Comfort Systems BF-20-2

Empire Comfort Systems BF-20-2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – TABLE OF CONTENTS
  • Page 3 – THIS IS A HEATING APPLIANCE; IMPORTANT SAFETY INFORMATION
  • Page 4 – SAFETY INFORMATION FOR USERS OF LP-GAS
  • Page 6 – WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS; PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR
  • Page 7 – GAS SUPPLY
  • Page 8 – CLEARANCES
  • Page 9 – WALL MOUNT INSTALLATION
  • Page 10 – LIGHTING INSTRUCTIONS
  • Page 11 – MAIN BURNER FLAME CHARACTERISTICS
  • Page 12 – PILOT FLAME CHARACTERISTICS
  • Page 13 – APPLIANCE MAINTENANCE
  • Page 14 – TROUBLESHOOTING
  • Page 15 – PARTS LIST
  • Page 16 – PARTS VIEW
  • Page 17 – OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
  • Page 18 – OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued)
  • Page 19 – SERVICE NOTES
Loading the manual

16943-5-0806

Page 1

INSTALLATION INSTRUCTIONS

AND

OWNER'S MANUAL

UNVENTED

ROOM HEATER

MODELS

BF-10-2 BF-20-2 BF-30-2

EFFECTIVE DATE

AUGUST 2006

WARNING: If not installed, operated and

maintained in accordance with the manufactur-

er's instructions, this product could expose you

to substances in fuel or from fuel combustion

which can cause death or serious illness.

This is an unvented gas-fired heater. It uses air

(oxygen) from the room in which it is installed.

Provisions for adequate combustion and venti-

lation air must be provided. Refer to page 6.

WATER VAPOR: A BY-PRODUCT OF

UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An

unvented room heater produces approximately

one (1) ounce (30ml) of water for every 1,000

Btu (.3KW's) of gas input per hour. Refer to

page 6.

This appliance may be installed in an after-

market, permanently located, manufactured

(mobile) home, where not prohibited by local

codes.
This appliance is only for use with the type of

gas indicated on the rating plate. This appliance

is not convertible for use with other gases.

Installer: Leave this manual with the appli-

ance.

Consumer: Retain this manual for future refer-

ence.

— Do not store or use gasoline or other flamma-

ble vapors and liquids in the vicinity of this or

any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas suppli-

er’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

— Installation and service must be performed by

a qualified installer, service agency or the gas

supplier.

WARNING: If the information in these instruc-

tions are not followed exactly, a fire or explosion

may result causing property damage, personal

injury or loss of life.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS

Page 2 16943-5-0806 SECTION PAGE Important Safety Information ......................................................................................................................3Safety Information for Users of LP Gas ...................................................................................

Page 3 - THIS IS A HEATING APPLIANCE; IMPORTANT SAFETY INFORMATION

16943-5-0806 Page 3 THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of more than 10,000 Btu...

Page 4 - SAFETY INFORMATION FOR USERS OF LP-GAS

Page 4 16943-5-0806 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detec...

Other Empire Comfort Systems Models

All Empire Comfort Systems Other