Emerson Xtreme Density - Manual

Emerson Xtreme Density

Emerson Xtreme Density – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
Page: / 84

Table of Contents:

  • Page 3 – TABLE OF CONTENTS; XD S
  • Page 4 – ii; XD C; FIGURES
  • Page 5 – iii
  • Page 6 – iv; TABLES
  • Page 7 – System Description; YSTEM; Enthalpy
  • Page 8 – European Union Fluorinated Greenhouse Gas Requirements; Liebert XD systems are available in; Direct; Indirect; configurations—differentiated essentially; Figures 2; and; Liebert; Indirect Liebert XD System Configuration
  • Page 9 – Liebert XDO—Overhead Cooling Module; connection to the refrigerant distribution pipes.; Figure 4
  • Page 10 – Liebert XDV—Vertical, Above-Cabinet Cooling Module; charge it downward into the cold aisle.; Figure 5; arrangement
  • Page 11 – Liebert XDH—Horizontal Cooling Module; end for easy connection to the refrigerant distribution pipes.; Figure 7
  • Page 12 – Liebert XDCF; easy connection to the refrigerant distribution pipes.; Figure 8
  • Page 13 – Liebert XDA—Air Flow Enhancer; Figure 9
  • Page 14 – Liebert XDP—Pumping Unit; Minimum Load; Figure 10 Liebert XDP pumping unit
  • Page 15 – Liebert XDC—Refrigerant Chiller; Figure 11 Liebert XD Chiller unit
  • Page 16 – Liebert XD Piping; Flexible Piping Kit; Field piping kits are available in several versions; - Liebert XD Piping Dimensions and Features; Liebert XD Connection Port Kit; kit sizes are available:; Figure 12 Liebert XD connection port kit
  • Page 17 – Starting a New Equipment Cooling Project; TARTING; Determining Cooling Equipment Needs
  • Page 18 – Implementing a Hot-Aisle/Cold Aisle Design
  • Page 19 – Designing a Liebert XD Solution; ESIGNING; OLUTION; space cooling applications.; Determine Cooling Requirements and Select Liebert XD System; increases in heat load.; NOTE; concurrently with normal operating capacity.
  • Page 20 – Selecting Liebert XD Cooling Modules; Number of Modules Supported by a Liebert XDP or Liebert XDC; bert XDC’s model size number.; Table 2
  • Page 21 – Liebert XDO Placement; Determining Spacing of Liebert XDOs in an Aisle; the remainder between these end units in pairs as shown in; Figure 14 Liebert XDO placement over cold aisle
  • Page 22 – Figure 15 Liebert XDO spacing—horizontal and vertical
  • Page 23 – Liebert XDV Unit Placement; of hot air drawn into the unit.; Table 4; Input Information
  • Page 24 – Liebert XDCF Placement; the power modules (see; Figure 17 Liebert XDCF unit mounting locations; Liebert XDCF Modules
  • Page 25 – Liebert XDH Placement; Figure 18 Liebert XDH placement; Hot
  • Page 26 – Interlaced piping arrangement
  • Page 28 – Liebert XD Refrigerant; dard 15-2001, Safety Standard for Refrigeration Systems; Example; Liebert XD Piping System Design; The guidelines provided for pipe size must be; CAUTION; installed to meet some local codes.
  • Page 29 – below for recommended pipe sizes and; Table 5; Liebert XDC
  • Page 30 – Figure 24 Hydraulic diagram; Liebert XD Piping Slope; XD module in the circuit. See; Table 6; Cumulative Model Size
  • Page 31 – Figure 25 Bypass flow controller details, dimensions; Liebert XD; Liebert XDP
  • Page 32 – Determining Refrigerant Volume; After the preliminary system design is completed,; may be used to determine; All lengths in; Tables 7; System refrigerant volume calculations in; Tables 7; Table 7; Per Liebert XD Unit; Table 8; Supply/Return Main Length and Diameter; Table 9; Hard-Piped Connector Length and Diameter
  • Page 33 – Metal Flex Pipe Connector Length
  • Page 34 – Calculating Refrigerant Charge—Example; Liebert XDC DX R-407c Circuit Volume—Air Cooled Units; Calculating refrigerant charge—example; Liebert XDP/Liebert XDC; Worksheet to calculate refrigerant charge; Indoor unit refrigerant charge—R-407c
  • Page 35 – Chilled Water Piping; Outdoor condenser charge—R-407c; Model; ndoor water/glycol cooled module – R-407c refrigerant charge
  • Page 36 – Liebert XDO Standard Features; electrical components.; Refrigerant Pre-Charge; (for use with prefabricated piping assemblies)—Field-installed; External Mounting Brackets; —The Liebert XDO unit can be suspended by external mounting; Condensate Detection
  • Page 37 – BACK; Rear of XDO
  • Page 39 – Figure 31 Liebert XDO top and front electrical access points; Liebert XDV Standard Features; or the bottom of the unit.; TOP OF XDO; The low-voltage connection is present only if
  • Page 40 – —The Liebert XDV can be suspended from the overhead building; Field-Installed Flexible Piping
  • Page 41 – Figure 33 Liebert XDV dimensions with one-shot connection; Detail “A”; TOP VIEW OF
  • Page 42 – POWER
  • Page 43 – Rear of XDV
  • Page 44 – washer provided in kit
  • Page 46 – Liebert XDCF Standard Features
  • Page 47 – Liebert XDCF Mechanical Considerations; illustrates the unit’s dimensions and the location of pipes.; Figure 40 Overall dimensions
  • Page 48 – Liebert XDCF Installation Considerations; Figure 41 Liebert XDCF unit mounting locations; Liebert XDCF Piping Connection Methods and Points; erant inside the Liebert XDCF.; WARNING; release pressurized R-134a refrigerant from the Liebert XDCF.
  • Page 49 – Figure 42 Liebert XDCF supply and return piping access points; Liebert XDH Standard Features; Supply Pipe; Pipe locations and
  • Page 50 – FRONT; Top of Liebert XDH; Rear of XDH
  • Page 51 – Slope; during installation.; Recommended Arc; Refer to Table 5 for details.
  • Page 52 – Liebert XD Flex Pipe Kit; Liebert XD Flex Pipe assemblies, supply and return; Min Bend Radius, Supply
  • Page 53 – Liebert XD Piping Dimensions and Features; Piping Installation Method prefabricated headers; Two-port prefabricated piping legend; Branch Piping; Supply; Nominal
  • Page 54 – Four-port prefabricated piping legend
  • Page 55 – Five-port prefabricated piping legend
  • Page 56 – Ten-port prefabricated piping legend; ODS
  • Page 57 – Liebert XDP Standard Features; Figure 50 Liebert XDP dimensions; Unit Dimensional Data; Overall
  • Page 58 – A - Return From Cooling Modules
  • Page 59 – Figure 52 Front view of Liebert XDP and electrical enclosure; Status Lamps; Enclosure Cover Not Shown for Clarity
  • Page 61 – Liebert XDC Standard Features; ual reset high-pressure switch and pump down low-pressure switch.; Figure 56 Liebert XDC dimensional data; Air Cooled
  • Page 62 – Air Cooled Models
  • Page 63 – Liebert XDC Water/Glycol Piping Connection Sizes; Customer Provided Piping
  • Page 64 – Figure 59 Piping locations—floor stand and valve assembly
  • Page 65 – Figure 60 Front view of Liebert XDC and electrical enclosures
  • Page 68 – HEAT REJECTION ELECTRICAL
  • Page 69 – Figure 68 Liebert XDC Extra Low Voltage field connections points; Requires shielded cable
  • Page 70 – Specifications; PECIFICATIONS; Liebert XDC160 specifications
  • Page 71 – Floor stand specifications—water-cooled Liebert XDC; Performance Data; Floor stand specifications—Liebert XDC with 40% propylene glycol
  • Page 72 – Floor stand specifications—Liebert XDC with 40% ethylene glycol
  • Page 73 – Liebert XDP160 specifications
  • Page 74 – Liebert XDO16 specifications
  • Page 75 – Liebert XDO20 specifications
  • Page 76 – Liebert XDO20 dimensions—domestic and export; All Models
  • Page 77 – Liebert XDV8 specifications
  • Page 78 – Liebert XDV10 specifications
  • Page 79 – Liebert XDV8 dimensions—domestic and export
  • Page 80 – Liebert XDH specifications
  • Page 81 – Notes
  • Page 84 – Precision Cooling
Loading the manual

Precision Cooling
For

Business-Critical Continuity™

Liebert

®

Xtreme Density

System Design Manual

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS; XD S

i TABLE OF CONTENTS 1.0 S YSTEM D ESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 European Union Fluorinated Greenhouse Gas Requirements . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2 Direct and Indirect System Configura...

Page 4 - ii; XD C; FIGURES

ii 3.20 Display Panel and Remote Temperature/Humidity Sensor Locations . . . . . . . . . . . . . . . . . 29 4.0 L IEBERT XD C OOLING M ODULES —L IEBERT XDO, L IEBERT XDV, L IEBERT XDH AND L IEBERT XDCF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30...

Page 5 - iii

iii Figure 24 Hydraulic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Figure 25 Bypass flow controller details, dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25F...

Other Emerson Models