Emerson V150- User Manual
Emerson V150– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Basis Weight Actuator; HT denotes High Torque
- Page 3 – Specifications; Valve; See the Specifications table.; Driver Card; Description of Terminal Functions; S, It may be driven from an external
- Page 4 – System Description
- Page 5 – Included as standard in the Stepmotor Interface are:
- Page 6 – Note; Installation; Valve and Actuator
- Page 7 – CAUTION
- Page 8 – WARNING
- Page 9 – Motor; Limit Switches; Connect ground to the terminal block.; External Control Signal; Manual Station Input Wiring
- Page 11 – Input Signal Options; Optional Remote Position Indication
- Page 12 – Settings; Plug the motor drive back into the IC2000.; Plug the IC500 module back into the cabinet.; Start Up
- Page 13 – Turn on power to the Stepmotor Interface.
- Page 15 – Adjustment
- Page 16 – Replace the travel indicator cover and screws.; Stroking Speed
- Page 18 – Valve Position Indicator
- Page 19 – Maintenance; Use bypass valves or completely
- Page 20 – Troubleshooting; If the actuator will not operate,
- Page 21 – Test Procedures; Checking the SD13 Card; Checking the IC500 Card; Valve Maintenance
- Page 22 – Replacing the Actuator Motor; Unlock and open the Stepmotor Interface.; Replacing the Transformer
- Page 23 – Field Installation of the Remote Station; Parts List
D101628X012
Basis Weight Control SKF Actuator with PEAB
IC2000 Stepmotor Interface
Contents
Introduction
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scope of Manual
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Valve
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Actuator and Stepmotor Interface
3
. . . . . . . . . . . . . .
Feedback Transmitter
3
. . . . . . . . . . . . . . . . . . . . . . . .
Driver Card
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Description
4
. . . . . . . . . . . . . . . . . . . . . . .
Installation
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Valve and Actuator
6
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Settings
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Start Up
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjustment
15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Limit Switches
15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stroking Speed
16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Valve Position Indicator
18
. . . . . . . . . . . . . . . . . . . . . .
Maintenance
19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Procedures
21
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Valve Maintenance
21
. . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the Actuator
21
. . . . . . . . . . . . . . . . . . . . . .
Mounting the Actuator on the Valve
22
. . . . . . . . . . .
Replacing Fuses
22
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing the Actuator Motor
22
. . . . . . . . . . . . . . . . .
Replacing Modules
22
. . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing the Transformer
22
. . . . . . . . . . . . . . . . . . .
Field Installation of the Remote Station
23
. . . . . . . .
Parts List
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COVER LATCH
Figure 1. Basis Weight System with Vee-Ball Valve, SFK
Actuator and IC2000 Stepmotor Interface
PEAB IC2000 CONTROL
CABINET
WIRE ACCESS PLATE
(ADDITIONAL PLATE ON BOTTOM)
PLUG-IN
ELECTRONICS
MODULES
SKF
ACTUATOR
STEPPING
MOTOR
LOCK
W5392 / IL
Introduction
Scope of Manual
This instruction manual provides instructions for ap-
plication and use of the SKF actuator and PEAB (Pro-
cess instrument and Electro AB) IC2000 Stepmotor
Interface in a basis weight system. Refer to the sepa-
rate instruction manual for valve instructions.
Instruction Manual
Form 5276
March 2000
Basis Weight Actuator
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Basis Weight Actuator 2 Table 1. Specifications Actuator Sizes J 20HT J 30HT or J 40HT HT denotes High Torque Enclosure Protection Actuator/Motor: IP54IC2000: IP55Remote Station: IP40 Resolution (for 90 Degrees of Valve Rotation) (2) Size 20HT: 5600 stepsSize 30HT: 8800 stepsSize 40HT: 11300 steps A...
Basis Weight Actuator 3 Only personnel qualified through training or experienceshould install, operate, or maintain this equipment. Do not attempt to install, operate, or maintain thisproduct without this instruction manual and the valveinstruction manual. If you have any questions concern-ing these...
Basis Weight Actuator 4 Dimension 20HT 30HT 40HT mm AB C 306155 90 455228122 565286134 D EF 50 120 50 80 176 85 100230115 G H K L 35 8.5 6346 60 10.5 9272 80 12.5 116 92 Inches AB C 12.06.103.54 17.98.984.80 22.2 11.22 5.28 D EF 1.974.721.97 3.156.933.35 3.949.064.53 G H K L 1.380.332.481.81 2.360.4...