Emerson TG-0807 - Manual

Emerson TG-0807

Emerson TG-0807 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 3 – Technical Guide; TABLE OF CONTENTS; Daniel Series 1500 Liquid Turbine Flow Meter; FOREWORD; for modern liquid measurement requirements.
  • Page 4 – TURBINE METER PARAMETERS; thus further improvements in measurement accuracy is possible.
  • Page 5 – THE DANIEL; UMBs are also 90o electrically out of phase.; Flow Computer
  • Page 6 – Daniel; TURBINE METER THEORY; of the volume measured.; FLOW RATE IS PROPORTIONAL TO ANGULAR VELOCITY; proportional to flow rate.; Figure 3 - Liquid Turbine Flow Meter Cross Section
  • Page 7 – PATENTED* FLOATING ROTOR; reverse flow direction is reduced.; Figure 4 - Rotor Assembly Cross Section
  • Page 8 – Surge And Pressure Relief Valves; MAGNETIC PICKOFF OF ROTOR VELOCITY; permanent magnet in the pickoff coil.; Figure 5 - Assembly of Daniel
  • Page 9 – TURBINE METER ROTOR AND BEARING DESIGN; are both upstream and downstream hangers.
  • Page 10 – RIMMED ROTORS FOR HIGHER RESOLUTION; The Daniel
  • Page 11 – DANIEL; space at a load rack.; Liquid Turbine Flow Meter
  • Page 12 – USGPM
  • Page 13 – Standard; ” and 1.5” Stainless Steel; Viscosity and Specific Gravity
  • Page 14 – suited to those applications where downtime is unacceptable.; Deflector Ring
  • Page 15 – minimum to extended maximum flowrange.; Low specific gravities or high viscosities will reduce
  • Page 16 – Size
  • Page 17 – RANGEABILITY OF LIQUID TURBINE FLOW METERS; range will be affected.
  • Page 19 – METER PERFORMANCE IN HIGH VISCOSITY LIQUIDS; Nominal Line Sizes; Sizing Ratio; may increase the wear rate of the turbine.
  • Page 20 – INSTALLATION AND OPERATING RECOMMENDATIONS; Manual of Petroleum Measurement Standards, Chapter 5, Section 3.; Figure 11 - Small Diameter; ready access to the straightening vanes is afforded. (See Figure 13)
  • Page 21 – where space is at a premium.; BACK PRESSURE; The necessary back pressure required is given by the equation:
  • Page 22 – The turbine pickoff coil has a high impedance and
Loading the manual

Technical Guide

DAN-LIQ-Turbine Meter-TG-0807

August 2007

www.daniel.com

Daniel

®

Liquid Turbine

Flow Meter Technical

Guide

Liquid Turbine Flow Meters

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Technical Guide; TABLE OF CONTENTS; Daniel Series 1500 Liquid Turbine Flow Meter; FOREWORD; for modern liquid measurement requirements.

Technical Guide DAN-LIQ-Turbine Meter-TG-0807 August 2007 TABLE OF CONTENTS Turbine Meter Parameters ............................................................................................................................. 1The Daniel Series 1200 and 1500 Liquid Turbine Flow Meter Systems .........

Page 4 - TURBINE METER PARAMETERS; thus further improvements in measurement accuracy is possible.

Technical Guide DAN-LIQ-Turbine Meter-TG-0807 August 2007 Page 1 +0.15% –0.15% +0.02% –0.02% TURBINE METER PARAMETERS These five terms are the most widely discussed parameters of turbine meter applications. Linearity is the measure of variation in signal output across the nominal flow range of the m...

Page 5 - THE DANIEL; UMBs are also 90o electrically out of phase.; Flow Computer

Technical Guide DAN-LIQ-Turbine Meter-TG-0807 August 2007 Page 2 THE DANIEL ® SERIES 1200 AND 1500 LIQUID TURBINE FLOW METER SYSTEMS The Daniel Series 1200 and 1500 Liquid Turbine Flow Meter Systems combine turbine meters and electronic instrumentation to measure volumetric total flow and/or flow ra...

Other Emerson Models