Emerson NT5C06D- Manual

Emerson NT5C06D

Emerson NT5C06D– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
Page: / 56

Table of Contents:

  • Page 3 – Astec; Advanced Power Systems; Installation and User Manual
  • Page 5 – Publication history
  • Page 6 – This page is left blank intentionally.
  • Page 7 – Contents
  • Page 9 – List of Figures
  • Page 11 – Description; negative slope method.
  • Page 12 – Applications; operate in temperatures ranging from 0°C to 65°C.; Equipment Identification; options for the NT5C06D Rectifier, and the MPS75 power shelves.
  • Page 13 – V for floating a 23 or 24 cell battery string.
  • Page 14 – Figure 3 - NT5C06D Switch Mode Rectifier
  • Page 15 – Electrical specifications; Engineering department of Astec Advanced Power Systems).; Table 1 - Electrical specifications
  • Page 16 – Output noise and ripple; shelf and with the rectifier in the local sensing mode.; Efficiency and Power Factor
  • Page 17 – Environmental specifications
  • Page 19 – Installation and start up; Tools and test equipment
  • Page 20 – Procedure 1 - Installing the power shelf; Release the clamping bar from the front of the power shelf; Wiring the power shelf; The power shelf wiring should be installed by qualified; DANGER
  • Page 21 – Installing the AC power; 2 AWG for each rectifier
  • Page 22 – Figure 5 - Power shelf individual AC connection; the wire does not interfere with the rectifier connections.; CAUTION; been instructed to do so in the appropriate procedure.; DC Conductors Installation
  • Page 23 – Table 4 - DC cable wire size; Control and Alarm Connections
  • Page 24 – Both RFA and Fan alarm relays are energized during; Designation
  • Page 25 – The normally closeed (NC) annotation signifies that the
  • Page 26 – Refer to MS5C06 for available 8-pin ribbon signal cables
  • Page 27 – S IG N A L
  • Page 28 – Verification; Verify that the power shelf has been mechanically secured.; Installing the rectifier; Release the clamping bar by loosening the two captive screws; Factory setting; The rectifier is factory set as indicated in Table 7.
  • Page 29 – Rectifier meter accuracy; Repeat the following steps for each rectifier in turn.; Procedure 4 - Starting up the rectifier; Close the AC circuit breaker in the AC service (main) panel.; Float Voltage Adjustment :
  • Page 30 – Step Action; Share
  • Page 31 – Slope load sharing
  • Page 32 – Slope Load Share; SLS / FS switch of each rectifier must be pushed towards the SLS.; Forced Load Share; Procedure 5 - Adjusting the load share; Verify that all the share mode settings are the same SLS or FS.
  • Page 33 – circuitry and the cooling fan unit.
  • Page 34 – Front panel controls
  • Page 35 – This unit does not have a start-up delay.; Indicators; Table 8 - Indicators; RFA; Fan failure alarm
  • Page 36 – Remote ON/OFF control; will be transmitted through the signal connector only.; Current limiting
  • Page 37 – Sequential start; Discharge of output capacitors; disconnected from the batteries or parallel units.
  • Page 39 – Figure 10 - Power interface connections; Signal interface connector
  • Page 40 – Figure 11 - Control signal connections
  • Page 41 – If the unit operates in a dusty environment the optional; Do not install a wet filter on the unit; Procedure 6 - Adjusting the float / equalize; Open the DC circuit breaker.
  • Page 42 – and Verification” section of this manual.; Cooling fan; Do not attempt to access the inside of the unit with a tool; Fan failure
  • Page 43 – Fan replacement; Before replacing the fan, turn the rectifier OFF.; Keep any dirt, dust, moisture or metallic particles from; Procedure 7 - Replacing the fan; Replace with a new one.
  • Page 44 – Ensure that the fans spin freely, without interference.
  • Page 45 – Do not run the rectifier without a fully operational fan or; Power shelf; The power shelf requires no maintenance.
  • Page 47 – Alarm indication; Table 9 - System fault diagnosis; An internal high voltage shutdown (HVSD) has
  • Page 48 – SEN FAIL fault
  • Page 49 – ITEM CPC; Fan Assembly
  • Page 51 – Appendix B: Technical service assistance; Local toll-free prefixes; Country Prefix
  • Page 52 – Toll-free technical assistance numbers; In Asia and the Pacific:
  • Page 53 – List of terms and acronyms
  • Page 54 – TBD
  • Page 56 – Single Phase
Loading the manual

Astec

Advanced Power Systems

Astec

Advanced Power Systems

A part of Emerson Network Power

UM5C06D ( 169-2071-504 )

Helios Rectifier 25/48

Single Phase -48V, 25 A

Power Factor Corrected Switch Mode Rectifier
NT5C06D

Installation and User Manual

P0831010 Standard 7.00 May 2001

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Emerson NT5C06D

Summary

Page 3 - Astec; Advanced Power Systems; Installation and User Manual

Astec Advanced Power Systems Helios Rectifier 25/48  NT5C06D Installation and User Manual Helios Rectifier 25/48 Single Phase -48V, 25A Power Factor Corrected Switch Mode Rectifier NT5C06D Installation and User Manual Manual Number : UM5C06D ( 169-2071-504 ) Manual Status : Standard Manual Issue : ...

Page 5 - Publication history

5 Helios Rectifier 25/48  NT5C06D Installation and User Manual Publication history May 2001 Standard issue 7.00. Manual modified to reflect the Emerson identity. ( EC 102-26438 ) September 1999 Standard 6.0. Document modified to be in accordance with Astec standards. (ECN 102-17331) May 1999 Standa...

Page 6 - This page is left blank intentionally.

6 Publication history UM5C06D ( 169-2071-504 ) P0831010 Standard 7.00 May 2001 This page is left blank intentionally.

Other Emerson Models