Table of Contents:

  • Page 2 – Product Data Document; Bristol; Remote Automation Solutions; Scalability; work Configuration and Communication
  • Page 3 – CPU; Historical Archive memory: Stored in either flash; Communication; To minimize field wiring and eliminate the need for
  • Page 4 – ControlWave Digital Input Module
  • Page 5 – ControlWave Digital Output Module; Configurable Fail State ‘OFF’, or ‘Hold Last; ControlWave Analog Input Module; Input Configuration: Isolated voltage input: 500; Thermocouple Input Module
  • Page 6 – RTD Input Module; Configurable Output Fail State (hold last value,; ControlWave Universal Digital Input Module and; Each counter input can be configured as a
  • Page 7 – input and to field common; Remote Termination Modules; Features; Up to 14 AWG wire with compression screw; Available Modules
  • Page 8 – I/O Expansion Rack to fit into any local or wide; Hardware Features; Internal loop power for I/O simplifies installation; creased system flexibility depending on the process; Specifications; Communication Processor
  • Page 9 – ControlWave Redundant System; Upgrade programs on the fly; OpenBSI; Simply Creative; Process Control and Communications Redundancy
  • Page 10 – OpenBSI Utilities; plication LaunchPad
  • Page 11 – Local Configuration Wizard; or RTU to download system flashware upgrades,; WebBSI; - WebBSI is a powerful and flexible soft; Configuration Wizard simplifies network setup; DataView; DataView for Real-time data display; Real-time ActiveX Controls; One of the many benefits OpenBSI brings to you is; ActiveX Controls
  • Page 12 – Required Software; Historical Data Collection; High Historical Data Integrity
  • Page 13 – ControlWave Open Network Connectivity; Modbus Protocol; Generic Serial Interface
  • Page 14 – Run Mode; Multi-User Security Access
  • Page 18 – ControlWave Installation Drawing; DETAIL; ASSEMBLY; All Dimensions Are In Inches
  • Page 19 – ControlWave Base Unit
  • Page 20 – DESCRIPTION; -20 mA Internally or Externally powered AI; Notes; Note 4: For conformal coating add -C suffix to each part number.
  • Page 21 – Open Drain - 500 mA current capability, 30 mS filter
  • Page 22 – ControlWave Redundancy; Comm Port Configurations CWREDCPUCP
Loading the manual

Product Data Document

420DS-1k

July 16, 2007 - Page 1

Website: www.EmersonProcess.com/Remote

Remote Automation Solutions

Bristol

®

ControlWave

®

PAC

Process Automation Controller

Bristol® ControlWave® PAC, from Emerson Pro-

cess Management, is a highly adaptable, high

performance Process Automation Controller with

exceptional networking capability to provide a

complete Process Automation Management Solu-

tion. Designed with a great emphasis on scalability

and modularity, ControlWave can be configured to

maximize the performance of a wide range of con-

trol systems, from small or mid-size applications to

large ones. Additionally, due to its small form factor

and rugged industrial design, ControlWave offers an

outstanding ability to match the requirements of the

most demanding process plant and SCADA system

environments. Above all, Emerson has developed

this innovative controller to provide cost-effective

solutions by minimizing the time required for instal-

lation and configuration.

Through this new open architecture, ControlWave

provides an ideal hybrid union of PLC, RTU and

DCS without compromising the unique features

and capabilities of each product. Consequently, the

ControlWave Process Automation Controller not

only introduces the great possibilities of an open

architecture for emerging communication standards,

but it also provides a simple solution for existing

networks. From its conception, ControlWave was in-

tended as a very flexible system capable of satisfy

-

ing the requirements of local, expanded, remote and

distributed I/O combinations. It is widely accepted

as a scalable platform because it can be used for

small applications using a single rack, but it can

also be expanded to large applications spanning an

entire plant.

Hardware Features

586 based processor provides unparalleled

performance
Up to three 100/10 MB Ethernet ports
Ethernet remote I/O
Up to four serial communication ports
2, 4, and 8 I/O slot panel mount chassis, panel

or 19” rack mount on 8 slot chassis
Single and double density I/O modules
Hot Swap I/O replacement
Security key-lock to prevent unauthorized

access

Internal loop power for I/O simplifies installation

AOs maintain last/preset value on CPU

Watchdog
DOs maintain last or zero value on CPU

Watchdog
Wide temperature range (-40 to +70ºC)
Class I, Div. 2 hazardous location and CE

approval
Open, industry standards for programming,

configuration and communication








"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Product Data Document; Bristol; Remote Automation Solutions; Scalability; work Configuration and Communication

Product Data Document 420DS-1k July 16, 2007 - Page 2 Bristol ® ControlWave ® PAC Remote Automation Solutions Website: www.EmersonProcess.com/Remote ControlWave Designer with ACCOL III To minimize your engineering and development time, we have adopted the international standard for PLC programming, ...

Page 3 - CPU; Historical Archive memory: Stored in either flash; Communication; To minimize field wiring and eliminate the need for

Product Data Document 420DS-1k July 16, 2007 - Page 3 Bristol ® ControlWave ® PAC Remote Automation Solutions Website: www.EmersonProcess.com/Remote PID & Lead/LagAGA gas flow and liquids calculations File handling In addition, ControlWave ensures data integrity, in the event of a communication ...

Page 4 - ControlWave Digital Input Module

Product Data Document 420DS-1k July 16, 2007 - Page 4 Bristol ® ControlWave ® PAC Remote Automation Solutions Website: www.EmersonProcess.com/Remote wire transmitters and dry contacts. For maximum channel-to-channel isolation, externally powered analog and digital inputs may be selected. Status-at-a...

Other Emerson Models