Emerson IB106-340 - Manual

Emerson IB106-340

Emerson IB106-340 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
Page: / 138

Table of Contents:

  • Page 2 – ESSENTIAL INSTRUCTIONS; READ THIS PAGE BEFORE PROCEEDING!
  • Page 3 – HIGHLIGHTS OF CHANGES; Page
  • Page 4 – Updated Figure 6-3 to include last calibration failed alarm.; Added Material Safety Data Sheets.
  • Page 5 – Changed Figure and Index No.; Updated the numbering of subsequent tables in Section 1.
  • Page 6 – Added new Quick Start Guide.
  • Page 7 – Instruction Manual; TABLE OF CONTENTS; AND; HART Communicator Manual O
  • Page 9 – LIST OF ILLUSTRATIONS
  • Page 10 – LIST OF TABLES
  • Page 11 – PREFACE; NOTE; NOTE TO USERS
  • Page 12 – IMPORTANT; the Operator Manual for instructions.
  • Page 13 – SECTION I. IDENTIFICATION; PRODUCT NAME; Vitreous Aluminosilicate Fibers with Silicon Dioxide.; CHEMICAL NAME; Watlow Columbia; HEALTH HAZARD SUMMARY; Possible cancer hazard based on tests with laboratory animals.
  • Page 14 – SECTION II. PHYSICAL DATA; APPEARANCE AND ODOR; SECTION III. HAZARDOUS INGREDIENTS; Zirconium Silicate; SECTION IV. FIRE AND EXPLOSION DATA; FLASH POINT: NONE; Use extinguishing agent suitable for type of surrounding fire.
  • Page 15 – SECTION V. HEALTH HAZARD DATA; THRESHOLD LIMIT VALUE; EYE; EXPOSURE TO USED CERAMIC FIBER PRODUCT; EPIDEMIOLOGY
  • Page 16 – TOXICOLOGY; and one rat exposed to 9 mg/m; EMERGENCY FIRST AID PROCEDURES; EYE CONTACT; SECTION VI. REACTIVITY DATA; STABILITY/CONDITIONS TO AVOID; Stable under normal conditions of use.; HAZARDOUS POLYMERIZATION/CONDITIONS TO AVOID
  • Page 17 – Incompatible with hydrofluoric acid and concentrated alkali.; SECTION VII. SPILL OR LEAK PROCEDURES
  • Page 18 – SECTION IX. SPECIAL PRECAUTIONS; PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING
  • Page 20 – WHAT YOU NEED TO KNOW; BEFORE INSTALLING AND WIRING A ROSEMOUNT; What type of installation does your system require?; STANDARD
  • Page 21 – CAN YOU USE THE FOLLOWING; tion options for the Oxymitter 4000 are shown in Figure 1.
  • Page 22 – QUICK START GUIDE
  • Page 23 – AC L1
  • Page 24 – QUICK REFERENCE GUIDE; Performing a Manual Calibration; CAL LED will flash continuously.
  • Page 25 – HART COMMUNICATOR FAST KEY SEQUENCES; Technical Support Hotline:
  • Page 27 – SECTION 1; SYSTEM OVERVIEW; value and; Description; is the partial pressure of the
  • Page 28 – Bulletin
  • Page 29 – Configuration; The CALIBRATION RECOMMENDED; REMOTE MOUNTED; Figure 1-2. Oxymitter 4000 Autocalibration
  • Page 31 – e. Handling the Oxymitter 4000
  • Page 34 – FRONT VIEW
  • Page 35 – Figure 1-6. Model 751 Remote Powered Loop
  • Page 39 – Part; includes bottle rack*
  • Page 40 – IMPS
  • Page 41 – SECTION 2; INSTALLATION
  • Page 42 – Figure 2-1. Oxymitter 4000 Installation
  • Page 43 – HORIZONTAL MOUNTED SPS 4000 A
  • Page 44 – Figure 2-3. Oxymitter 4000 with Abrasive Shield
  • Page 45 – Figure 2-4. Oxymitter 4000 Adapter Plate Dimensions
  • Page 46 – INSTALLATION FOR MASONRY; Figure 2-5. Oxymitter 4000 Adapter Plate Installation
  • Page 47 – Figure 2-6. Oxymitter 4000 Bracing Installation
  • Page 48 – If using the optional ceramic diffusion; Figure 2-7. Orienting the Optional Vee Deflector; Figure 2-8. Installation with Drip Loop and Insulation Removal
  • Page 49 – If the system has an abrasive shield,; Insert probe through the opening in the
  • Page 50 – Line; represents the O
  • Page 51 – Electrically connect the probe as follows:
  • Page 52 – f. Connect Remote Contact Input Wiring
  • Page 54 – Air
  • Page 55 – Gas; the Oxymitter 4000 connections.; Calibration Gas Connections; calibration gas 1 (high calibration
  • Page 57 – SECTION 3; a. Verify Mechanical Installation; Install the housing cover on the termi-
  • Page 58 – c. Verify Oxymitter 4000 Configuration
  • Page 60 – Handshake
  • Page 61 – Figure 3-3. Startup and Normal Operation
  • Page 62 – value upon the initiation; POWER UP
  • Page 63 – SECTION 4; b. Model 751 Remote Powered Loop LCD
  • Page 65 – SECTION 5; 1 character liquid crystal display (LCD)
  • Page 68 – Mode
  • Page 72 – CAL METHOD
  • Page 75 – SECTION 6; concentrations are applied to
  • Page 76 – Figure 6-1. Oxymitter 4000 Exploded View
  • Page 78 – ALARMS; Apply the first calibration gas.
  • Page 79 – Remove the first calibration; LED STATUS INDICATORS
  • Page 80 – LED
  • Page 81 – able working temperature.
  • Page 83 – Squeeze the J8 connector on the sides
  • Page 84 – Assembly
  • Page 86 – HEATER STRUT REPLACEMENT
  • Page 87 – CELL REPLACEMENT
  • Page 89 – Replacement
  • Page 90 – Thoroughly mix cement and insert tip; COMPONENT REPLACEMENT
  • Page 93 – POWER SUPPLY BOARD
  • Page 94 – d. Pressure Switch Replacement
  • Page 95 – Maintenance; Calibration Gas Flowmeter. Calibration; Shut off the calibration gases at the
  • Page 96 – Apply pipe thread sealant to the
  • Page 97 – Figure 6-13. Calibration Gas and Reference Air Components
  • Page 99 – SECTION 7; Noise
  • Page 100 – “low calibration gas flowing”.
  • Page 102 – nector is properly seated.
  • Page 103 – shorted thermocouple is likely.
  • Page 104 – couple wiring is reversed.
  • Page 106 – the heater connector J8.
  • Page 107 – The high high heater temp alarm will
  • Page 108 – If the case temperature exceeds 185°F
  • Page 109 – The low heater temperature alarm is
  • Page 110 – If the thermocouple produces a voltage
  • Page 111 – The platinum pad could also be at fault.
  • Page 112 – The bad cell alarm activates when the
  • Page 113 – This alarm can occur if the EEPROM is
  • Page 114 – During a calibration, the electronics
  • Page 115 – After a calibration has been performed,
  • Page 116 – The last calibration failed alarm acti-
  • Page 117 – If no alarms are indicated on the key-
  • Page 118 – Symptom
  • Page 119 – SYMPTOM — NO TEST GAS FLOW
  • Page 121 – SECTION 8
  • Page 123 – SECTION 9; Part Number
  • Page 127 – Table 9-2. Replacement Parts for Electronics
  • Page 131 – OPTIONAL ACCESSORIES; HART HANDHELD 275 COMMUNICATOR; ASSET
  • Page 133 – CALIBRATION GAS SEQUENCER; Rosemount Analytical’s O
  • Page 135 – INDEX
  • Page 137 – WARRANTY
Loading the manual

Instruction Manual

IB-106-340 Rev. 2.4
April, 2001

http://www.processanalytic.com

Oxymitter 4000

Oxygen Transmitter

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ESSENTIAL INSTRUCTIONS; READ THIS PAGE BEFORE PROCEEDING!

Emerson Process ManagementRosemount Analytical Inc.Process Analytic Division 1201 N. Main St.Orrville, OH 44667-0901T (330) 682-9010F (330) 684-4434e-mail: [email protected]://www.processanalytic.com ESSENTIAL INSTRUCTIONS READ THIS PAGE BEFORE PROCEEDING! Rosemount Analytical designs, ...

Page 3 - HIGHLIGHTS OF CHANGES; Page

HIGHLIGHTS OF CHANGES Effective May, 1998 Rev. 2.0 Page Summary — Modified existing manual to accommodate integrally mounted SPS 4000Single Probe Autocalibration Sequencer information. — Added locks for the electronic housing covers throughout the manual. — Changed test gas to calibration gas throug...

Page 4 - Updated Figure 6-3 to include last calibration failed alarm.; Added Material Safety Data Sheets.

HIGHLIGHTS OF CHANGES (CONTINUED) Effective May, 1998 Rev. 2.0 (Continued) Page Summary Page 6-4 Updated Figure 6-3 to include last calibration failed alarm. Page 6-6 Added fault 14 to Table 6-1. Page 6-14 Added NOTE to determine when to replace the diffusion element. Page 7-1 Added general troubles...

Other Emerson Models