Emerson Fisher Baumann 83000- User Manual
Emerson Fisher Baumann 83000– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – pertinent information.; WARNING; Educational Services; Emerson Process Management
- Page 3 – Instruction Manual; Maintenance; performing any maintenance operations:; Installation; guidelines shown below.
- Page 4 – Air Piping; to the 1/4 NPT in the lower diaphragm case. See figures 4 and 5.; Flow Direction; body bowl, Port A to port B. See figure 2 for port identification.; Use Flow to Open: Port B to A; In vacuum applications, vacuum on down stream.; Disassembly; relieve process pressure.
- Page 5 – Lapping Sealing Surfaces; the bonnet with a wrench until there is metal-to-metal contact.; Valve Body to Bonnet Assembly; CAUTION
- Page 6 – Note; Parts Ordering; using the following parts tables.; Use only genuine Fisher
- Page 7 – Figure 3. 83000 with Stem Adaptor for Baumann 32 Actuator
- Page 8 – Table 1. Common Parts
- Page 10 – Figure 8. Baumann 83000 - Rotated View to Show Locking Bolts; FIELDVUE DVC6000 Digital Valve Controller
- Page 11 – Figure 12. Baumann 16 Actuator with FIELDVUE; Figure 13. Baumann 16 Actuator with FIELDVUE
- Page 12 – Table 4. Baumann Actuator Weights
www.Fisher.com
Baumann™ 83000 Sanitary Angle
Control Valve
Contents
Introduction
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scope of Manual
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Precautions
2
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Educational Services
2
. . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air Piping
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flow Direction
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disassembly
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lapping Sealing Surfaces
5
. . . . . . . . . . . . . . . . . . . . . .
Bonnet Maintenance
5
. . . . . . . . . . . . . . . . . . . . . . . . .
Valve Body to Bonnet Assembly
5
. . . . . . . . . . . . . . . .
Calibration
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Ordering
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions and Weights
10
. . . . . . . . . . . . . . . . . . . . . .
Figure 1. Baumann 83000 Control Valve
83000 Sanitary Angle Valve
with Baumann 16 Actuator
W9849
W9848
83000 Sanitary Angle Valve
with FIELDVUE
t
DVC2000
Digital Valve Controller
Introduction
The Baumann 83000 Sanitary angle control valve (figure 1) features a packless design and is intended for laboratory
flow rates as low as 0.001 liters per minute (l/m) with a Cv range of 0.00001 to 1.2. This innovative design also allows
for clean-in-place (CIP) and sanitize-in-place (SIP) procedures and is self-draining. Meets 3-A sanitary standards for
design and fabrication.
Scope of Manual
This instruction manual includes installation, maintenance, and parts information for the Baumann 83000 sanitary
angle control valve.
Do not install, operate, or maintain Baumann 83000 control valves without being fully trained and qualified in valve,
actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is
important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and
warnings. If you have any questions about these instructions, contact your Emerson Process Management sales office
before proceeding.
Instruction Manual
D103367X012
83000 Valve
December 2014
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Instruction Manual D103367X012 83000 Valve December 2014 2 WARNING Always wear protective gloves, clothing and eyewear when performing any installation operations to avoid personal injury.Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts ...
Instruction Manual D103367X012 83000 Valve December 2014 3 Maintenance WARNING Avoid personal injury and property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations: D Do not remove the actuator from the valve while the valve is still pr...
Instruction Manual D103367X012 83000 Valve December 2014 4 WARNING To avoid personal injury or property damage, do not attempt to do any work on a valve while the system is in operation, the valve must be isolated 100% from the active system and the isolated line voided of pressure and/or hazardous ...