Emerson Fisher Baumann 83000- User Manual

Emerson Fisher Baumann 83000

Emerson Fisher Baumann 83000– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – pertinent information.; WARNING; Educational Services; Emerson Process Management
  • Page 3 – Instruction Manual; Maintenance; performing any maintenance operations:; Installation; guidelines shown below.
  • Page 4 – Air Piping; to the 1/4 NPT in the lower diaphragm case. See figures 4 and 5.; Flow Direction; body bowl, Port A to port B. See figure 2 for port identification.; Use Flow to Open: Port B to A; In vacuum applications, vacuum on down stream.; Disassembly; relieve process pressure.
  • Page 5 – Lapping Sealing Surfaces; the bonnet with a wrench until there is metal-to-metal contact.; Valve Body to Bonnet Assembly; CAUTION
  • Page 6 – Note; Parts Ordering; using the following parts tables.; Use only genuine Fisher
  • Page 7 – Figure 3. 83000 with Stem Adaptor for Baumann 32 Actuator
  • Page 8 – Table 1. Common Parts
  • Page 10 – Figure 8. Baumann 83000 - Rotated View to Show Locking Bolts; FIELDVUE DVC6000 Digital Valve Controller
  • Page 11 – Figure 12. Baumann 16 Actuator with FIELDVUE; Figure 13. Baumann 16 Actuator with FIELDVUE
  • Page 12 – Table 4. Baumann Actuator Weights
Loading the manual

www.Fisher.com

Baumann™ 83000 Sanitary Angle

Control Valve

Contents

Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Precautions

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Educational Services

2

. . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Piping

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Flow Direction

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Disassembly

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Lapping Sealing Surfaces

5

. . . . . . . . . . . . . . . . . . . . . .

Bonnet Maintenance

5

. . . . . . . . . . . . . . . . . . . . . . . . .

Valve Body to Bonnet Assembly

5

. . . . . . . . . . . . . . . .

Calibration

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts Ordering

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensions and Weights

10

. . . . . . . . . . . . . . . . . . . . . .

Figure 1. Baumann 83000 Control Valve

83000 Sanitary Angle Valve

with Baumann 16 Actuator

W9849

W9848

83000 Sanitary Angle Valve

with FIELDVUE

t

DVC2000

Digital Valve Controller

Introduction

The Baumann 83000 Sanitary angle control valve (figure 1) features a packless design and is intended for laboratory

flow rates as low as 0.001 liters per minute (l/m) with a Cv range of 0.00001 to 1.2. This innovative design also allows

for clean-in-place (CIP) and sanitize-in-place (SIP) procedures and is self-draining. Meets 3-A sanitary standards for

design and fabrication.

Scope of Manual

This instruction manual includes installation, maintenance, and parts information for the Baumann 83000 sanitary

angle control valve.

Do not install, operate, or maintain Baumann 83000 control valves without being fully trained and qualified in valve,

actuator, and accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is

important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and

warnings. If you have any questions about these instructions, contact your Emerson Process Management sales office

before proceeding.

Instruction Manual

D103367X012

83000 Valve

December 2014

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - pertinent information.; WARNING; Educational Services; Emerson Process Management

Instruction Manual D103367X012 83000 Valve December 2014 2 WARNING Always wear protective gloves, clothing and eyewear when performing any installation operations to avoid personal injury.Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts ...

Page 3 - Instruction Manual; Maintenance; performing any maintenance operations:; Installation; guidelines shown below.

Instruction Manual D103367X012 83000 Valve December 2014 3 Maintenance WARNING Avoid personal injury and property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations: D Do not remove the actuator from the valve while the valve is still pr...

Page 4 - Air Piping; to the 1/4 NPT in the lower diaphragm case. See figures 4 and 5.; Flow Direction; body bowl, Port A to port B. See figure 2 for port identification.; Use Flow to Open: Port B to A; In vacuum applications, vacuum on down stream.; Disassembly; relieve process pressure.

Instruction Manual D103367X012 83000 Valve December 2014 4 WARNING To avoid personal injury or property damage, do not attempt to do any work on a valve while the system is in operation, the valve must be isolated 100% from the active system and the isolated line voided of pressure and/or hazardous ...