Emerson ControlWave GFC- User Manual

Emerson ControlWave GFC

Emerson ControlWave GFC– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – Product Data Document; ControlWave GFC Plus; Remote Automation Solutions; tions for “chart replacements” and flow computers,; Control; fiberglass enclosure that has provisions for not only; Specifications – Package; recommended a kit for affixing to a 2” pipe or
  • Page 3 – Specifications – Operating Environment; SELECTION ITEM DESCRIPTIONS AND
  • Page 4 – SENSOR ASSEMBLY; Physical Specifications – Sensor Assemblies; assembly for the first run and an external, smart
  • Page 5 – MVT ASSEMBLY STATIC PRESSURE; Selection “E” specifies the housing, for which there; Features – Display/Keypads; Easy configuration via ACCOL III Function Block; Specifications – Display/Keypads; site, configuration and process data. The screens; The 2-button version is similar but includes only
  • Page 6 – PROCESSOR/ MAIN ELECTRONICS; CONFIGURATION” section for specifications).; SELECTION; Specifications for Processor/Electronics
  • Page 7 – CONTROLWAVE GFC PLUS STANDARD; The user’s interface to the Standard Ap-; Overview of the Standard Application Program
  • Page 8 – Average Specific Gravity
  • Page 9 – Communication Port Configuration for the Standard; POWER SYSTEM
  • Page 10 – Specifications – Charge Regulator and; HAZARDOUS AREA CERTIFICATION; Class I, Division 2 certification can be specified.; BENDABLE RTD; The bendable RTD is a “one size fits all” solution
  • Page 11 – RTD Interface Information; coefficients of a custom calibrated RTD, another; RTD Input Specifications; These specifications are for the interface, only, not; THERMOWELL OPTIONS FOR RTD; input to 21.4 Vdc for field devices such as transmit
  • Page 12 – Specifications for 21V dc/dc Power Supply
  • Page 13 – Configuration: Open Drain MOSFET
  • Page 14 – Power Consumption Information, Processor, Main; The figures, below, assume that the standard ap; POWER DISTRIBUTION BOARD; This option, specified in Selection “O,” organizes; RELAY BOARD; Express; ‘C’ configuration corresponding to two discrete
  • Page 15 – Specifications for the Relay Board; POLYPHASER OPTION FOR RADIO; If a radio is specified, you can specify whether or; MODEM OR RADIO OPTION; separately, Emerson offers “radio ready” configura; Modem Specifications; Modem Configuration: “AT” based commands.
  • Page 16 – Radio Specifications; For specifications on the radios, please refer to the; ACCESSORIES; PC CABLES; CD is the “BSI Config” CD, which also contains the
  • Page 17 – PRODUCT FAMILY COMPATIBILITY; This family compatibility is a major benefit to users; Open standards for programming, network con-; architecture and bring the optimal process efficiency; ControlWave; products. ControlWave Designer includes all five
  • Page 18 – ACCOL III; blocks, ControlWave Designer brings the benefit
  • Page 19 – DIMENSIONS; Integral, DP/P MVT assembly and Pole Mount hardware are shown.
Loading the manual

Product Data Document

1660ds9b / D301294X012

October 2011 - Page 1

www.EmersonProcess.com/Remote

ControlWave

®

GFC Plus

Gas Flow Computer

Remote Automation Solutions

Featuring the “Express” Electronics Platform

When requirements call for an integrated, “all in

one box” chart replacement or flow computer, the

ControlWave GFC Plus from Emerson Process

Management is a cost effective, competitive solu-

tion.

Unlike chart replacements, ControlWave GFC Plus

is also able to meets users’ automation needs and

easily supervises a two-run metering and regulating

station or plunger lift operations at a well site.

OVERVIEW

HARDWARE/PACKAGING FEATURES

32-bit ARM9 platform is capable of multiple flow

computing and process automation operations.
Smart, gauge pressure or DP/P sensor

assembly can be removed and replaced,

independently of the “top end” electronics.
Precision RTD interface provides very accurate

measurement.
Very low power consumption minimizes costs

of solar/battery power systems, which are also

integrated in the package.
Three serial communication ports are standard.

Standard I/O includes 2 DI/PI.

Optional I/O expansion includes 2 DI/DO, 4 DI,

2 DO, 2 High-speed Counter Inputs, 3 AI and 1

AO.
Integral LCD with optional, 25-key keypad

allows operators to view and change

configurable parameters, on site, without

packing a PC.
Broad selection of modem and wireless

communications are instrument package

options.

FIRMWARE/SOFTWARE FEATURES

Control

Wave GFC Plus is pre-programmed

to meet API 21.1 requirements for a two-run

metering station with networking via BSAP or

Modbus.

PC web style menu pages are pre-configured

for all user operations
Using our

Control

Wave Designer, IEC 61131-

3 programming environment, any user or third

party can modify the standard application or

create a completely customized program—and

full support from Emerson is available, every

step of the way.

ControlWave GFC Plus comes in a highly in-

tegrated package that includes a smart P/T or

DP/P/T (shown) sensor assembly, battery/so-

lar power system and a broad selection of mo-

dem and radio communications options.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Product Data Document; ControlWave GFC Plus; Remote Automation Solutions; tions for “chart replacements” and flow computers,; Control; fiberglass enclosure that has provisions for not only; Specifications – Package; recommended a kit for affixing to a 2” pipe or

Product Data Document 1660ds9b / D301294X012 October 2011 - Page 2 ControlWave GFC Plus Remote Automation Solutions www.EmersonProcess.com/Remote Additional, standard application programs will • be introduced on a continual basis.TeleFlow users will appreciate the compatibility • of ControlWave GFC ...

Page 3 - Specifications – Operating Environment; SELECTION ITEM DESCRIPTIONS AND

Product Data Document 1660ds9b / D301294X012 October 2011 - Page 3 ControlWave GFC Plus Remote Automation Solutions www.EmersonProcess.com/Remote www.ControlWave.com Specifications – Operating Environment Wide operating power input voltage range of 5.0 • to 18.0 VdcWhile this product can operate wit...

Page 4 - SENSOR ASSEMBLY; Physical Specifications – Sensor Assemblies; assembly for the first run and an external, smart

Product Data Document 1660ds9b / D301294X012 October 2011 - Page 4 ControlWave GFC Plus Remote Automation Solutions www.EmersonProcess.com/Remote SENSOR ASSEMBLY Using the sensor assembly, integrated in the instru- ment package is the easiest implementation for a single meter run; however, the stand...

Other Emerson Models