Table of Contents:

  • Page 2 – SPECIFICATIONS; Flame Current Requirements:; *Measured with a DC microammeter in the flame probe lead; TIMING SPECIFICATIONS; ANSI standard rated module timing.; OPERATING TEMPERATURE RANGE:; Surface mount multipoise; maximum; Flame Establishing Time:
  • Page 3 – MOUNTING AND WIRING; CAUTION; FIRE HAZARD; INSTALLATION
  • Page 4 – WIRING; MV LO; RO OUT; TYPICAL SYSTEM WIRING DIAGRAM
  • Page 5 – TYPICAL SYSTEM WIRING TABLE; Maximum recommended flame probe wire length is 36 inches.
  • Page 6 – OPERATION; OPTION SWITCHES; Stage operation; – If the Option Switch MODE is set to 2; AUTO; – On call for heat, the automatic second stage will; SYSTEM LOCKOUT FEATURES; COOL MODE
  • Page 7 – (System lockout will never override the; do one of the; DIAGNOSTIC FEATURES; If; FAULT RECALL; SYSTEM LOCKOUT AND DIAGNOSTIC FEATURES
  • Page 8 – HOMEOWNER HELP LINE; Red LED; TROUBLESHOOTING
Loading the manual

50M56-743

Integrated Single or Two-Stage

HSI Integrated Furnace Control Kit

INSTALLATION INSTRUCTIONS

DESCRIPTION

The 50M56-743 kit is an automatic gas HSI Integrated Fur-
nace Control that employs a microprocessor to continually
monitor, analyze, and control the proper operation of the gas
burner, inducer, and fan.
Signals interpreted during continual surveillance of the ther-
mostat and flame sensing element initiate automatic ignition
of the burner, sensing of the flame, and system shut-off during
normal operation.
These controls incorporate system fault analysis for quick gas
flow shut-off, coupled with automatic ignition retry upon sensing
a fault correction.

Installation should be done by a qualified heating and air
conditioning contractor or licensed electrician.
If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air
conditioning contractor or licensed electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.
Following installation or replacement, follow manufacturer’s
recommended installation/service instructions to ensure
proper operation.

PRECAUTIONS

CAUTION

!

Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage the
thermostat.

Failure to comply with the following warnings could result
in personal injury or property damage.

FIRE HAZARD

• Do not exceed the specified voltage.
• Replace existing control with exact model and

dash number.

• Protect the control from direct contact with water

(dripping, spraying, rain, etc.).

• If the control has been in direct contact with

water, replace the control.

• Label all wires before disconnection when

servicing controls. Wiring errors can cause
improper and dangerous operation.

• Route and secure wiring away from flame.

SHOCK HAZARD

• Disconnect electric power before servicing.
• Ensure proper earth grounding of appliance.
• Ensure proper connection of line neutral and line

hot wires.

EXPLOSION HAZARD

• Shut off main gas to appliance until installation

is complete.

WARNING

!

CONTENTS

Description ................................................................... 1
Precautions .................................................................. 1
Specifications .............................................................. 2
Installation ................................................................... 3
Mounting & Wiring
Operation ..................................................................... 6
System Lockout and Diagnostic Features ................... 7
Troubleshooting ........................................................... 8

www.white-rodgers.com

www.emersonclimate.com

PART NO. 37-7474A

1314

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

Operator: Save these instructions for future use!

50M56-743 Cross Reference Information

Goodman

White-Rodgers

0130F00006

PCBBF122

50M56 289

0130F00006S

PCBBF122S

PCB00109

PCBBF132

PCBBF109

PCBBF132S

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPECIFICATIONS; Flame Current Requirements:; *Measured with a DC microammeter in the flame probe lead; TIMING SPECIFICATIONS; ANSI standard rated module timing.; OPERATING TEMPERATURE RANGE:; Surface mount multipoise; maximum; Flame Establishing Time:

2 SPECIFICATIONS ELECTRICAL RATINGS [@ 77°F (25°C)]: Input Voltage: 25 VAC 50/60 Hz Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings:Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pfIgnitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive)Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VACCirculator Relay: 14....

Page 3 - MOUNTING AND WIRING; CAUTION; FIRE HAZARD; INSTALLATION

3 MOUNTING AND WIRING All wiring should be installed by a qualified heating and air conditioning contractor or licensed electrician, according to local and national electrical codes and ordinances.The control must be secured to an area that will experience a minimum of vibration and remain below the...

Page 4 - WIRING; MV LO; RO OUT; TYPICAL SYSTEM WIRING DIAGRAM

4 WIRING TH TR MV HI MV COM MV LO GND HLO HLI PSO PSI C R G W Y Y W G R THERMOSTAT 2 STAGE GAS VALVE HIGH LIMIT (N. C.) ROLLOUT (N. C.) AUX. HIGH LIMIT (N. C.) PRESSURE SWITCH (N. O.) COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER CIRCULATOR BLOWER 50M56 24 VAC 120 VAC 24 VAC CLASS II TRANSFORMER HOT (...