Emerson 50M56-7433 – Manual in PDF format online.

Manuals:

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8

Summary

Page 2 - SPECIFICATIONS; Flame Current Requirements:; *Measured with a DC microammeter in the flame probe lead; TIMING SPECIFICATIONS; ANSI standard rated module timing.; OPERATING TEMPERATURE RANGE:; Surface mount multipoise; maximum; Flame Establishing Time:

2 SPECIFICATIONS ELECTRICAL RATINGS [@ 77°F (25°C)]: Input Voltage: 25 VAC 50/60 Hz Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings:Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pfIgnitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive)Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VACCirculator Relay: 14....

Page 3 - MOUNTING AND WIRING; CAUTION; FIRE HAZARD; INSTALLATION

3 MOUNTING AND WIRING All wiring should be installed by a qualified heating and air conditioning contractor or licensed electrician, according to local and national electrical codes and ordinances.The control must be secured to an area that will experience a minimum of vibration and remain below the...

Page 4 - WIRING; MV LO; RO OUT; TYPICAL SYSTEM WIRING DIAGRAM

4 WIRING TH TR MV HI MV COM MV LO GND HLO HLI PSO PSI C R G W Y Y W G R THERMOSTAT 2 STAGE GAS VALVE HIGH LIMIT (N. C.) ROLLOUT (N. C.) AUX. HIGH LIMIT (N. C.) PRESSURE SWITCH (N. O.) COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER CIRCULATOR BLOWER 50M56 24 VAC 120 VAC 24 VAC CLASS II TRANSFORMER HOT (...