Emerson 5081C-HT - Manual

Emerson 5081C-HT

Emerson 5081C-HT – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Instruction Sheet; Specifications; pHySICAl SpeCIFICATIoNS
  • Page 3 – FIGURe 1. Infrared remote controller
  • Page 4 – pRoGRAM; process display
  • Page 5 – FIGURe 3. AMS configuration screen using HART
  • Page 6 – program Menu
  • Page 7 – Wiring; WIRING THRoUGH A jUNCTIoN boX; Recommended Transmitter Settings*; poWeR WIRING
  • Page 8 – Installation; UNpACKING ANd INSpeCTIoN
  • Page 9 – ROSEMOUNT; SIGNAL INPUT; Ex ia IIC T4 Ga; II 1 G; FIGURe 8. ATeX label Information
  • Page 10 – Figure 9. FMRC explosion-proof Installation
  • Page 11 – Figure 10. FM Hazardous Area Approval label
  • Page 12 – Figure 11. FM Intrinsically Safe Installation
  • Page 13 – Figure 12. CSA Hazardous Area Approval label
  • Page 14 – Figure 13. CSA Intrinsically Safe Installation
  • Page 15 – Engineering Specifications; To ReSeT TRANSMITeR To FACToRy deFAUlT
Loading the manual

Instruction Sheet

5081C-HT

LIQ_MAN_ABR_5081C-HT/Rev.G

January 2015

Remote Controlled HART

®

SMART

Two-Wire Conductivity Transmitter

WARNING

Substitution of components may impair Intrinsic Safety or
suitability for division 2.

WARNING

do not remove or replace while circuit is live unless area is
known to be non-hazardous.

WARNING

explosion Hazard - do not disconnect equipment unless area
is known to be non-hazardous.

WARNING

To prevent ignition of flammable or combustible atmos-
pheres, disconnect power before servicing or understand and
adhere to the manufacturer's live maintenance procedures.

SpeCIAl CoNdITIoN FoR INTRINSICAlly SAFe USe

The 5081 enclosure is made of aluminum alloy and given a
protective polyurethane finish; however, care must be taken
to protect it from impact, abrasion or friction with other
metal surfaces if located in zone 0.

WARNING

If a Model 475 Universal Hart® Communicator is used with
these transmitters, the software within the Model 475 may
require modification.
If a software modification is required, please contact your
local Fisher-Rosemount Service Group or National Response
Center at 1-800-654-7768.

ESSENTIAL INSTRUCTIONS

Read this page before proceeding!

Your purchase from Rosemount Analytical, Inc. has resulted in one of the finest instruments available for your particular

application. These instruments have been designed, and tested to meet many national and international standards.

Experience indicates that its performance is directly related to the quality of the installation and knowledge of the user in

operating and maintaining the instrument. To ensure their continued operation to the design specifications, personnel

should read this manual thoroughly before proceeding with installation, commissioning, operation, and maintenance of

this instrument. If this equipment is used in a manner not specified by the manufacturer, the protection provided by it

against hazards may be impaired.

• Failure to follow the proper instructions may cause any one of the following situations to occur: Loss of life; personal

injury; property damage; damage to this instrument; and warranty invalidation.

• Ensure that you have received the correct model and options from your purchase order. Verify that this manual

covers your model and options. If not, call 1-800-854-8257 or 949-757-8500 to request correct manual.

• For clarification of instructions, contact your Rosemount representative.
• Follow all warnings, cautions, and instructions marked on and supplied with the product.
• Use only qualified personnel to install, operate, update, program and maintain the product.
• Educate your personnel in the proper installation, operation, and maintenance of the product.
• Install equipment as specified in the Installation section of this manual. Follow appropriate local and national codes.

Only connect the product to electrical and pressure sources specified in this manual.

• Use only factory documented components for repair. Tampering or unauthorized substitution of parts and

procedures can affect the performance and cause unsafe operation of your process.

• All equipment doors must be closed and protective covers must be in place unless qualified personnel are

performing maintenance.

• If this equipment is used in a manner not specified by the manufacturer, the protection provided by it against

hazards may be impaired.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Instruction Sheet; Specifications; pHySICAl SpeCIFICATIoNS

2 5081C-HT Instruction Sheet January 2015 LIQ_MAN_ABR_5081C-HT/Rev.G Specifications pHySICAl SpeCIFICATIoNS Housing: Cast aluminum with epoxy coating. Type 4X (IP65). Neoprene O-ring cover seals. 160.5 mm x 175.3 mmx 161.3 mm (6.3 in. x 6.9 in. x 6.4 in.) diameter: 155.4 mm (6.1 in.) electrical Cond...

Page 3 - FIGURe 1. Infrared remote controller

INFRARed ReMoTe CoNTRolleR 1. Pressing a menu key allows the user access to calibrate, program, or diagnostic menus. 2. Press ENTER to store data and settings. Press NEXT to move from one submenu to the next. Press EXIT to leave without storing changes. 3 Instruction Sheet 5081C-HT LIQ_MAN_ABR_5081C...

Page 4 - pRoGRAM; process display

4 5081C-HT Instruction Sheet January 2015 LIQ_MAN_ABR_5081C-HT/Rev.G pRoGRAM MeNU MNeMoNICS 5000 25.0C 12.00mA CAL keyPROG keyDIAG keyHOLD key 5081C-HT Process Display Screen µ S/cm pRoGRAM FIGURe 2. Menu Tree CAlIbRATIoN dIAGNoSTICS process display Mtr CAL tE M P AbS C 0 air 5081-C-Ht CELL COnSt So...

Other Emerson Models