Emerson 1F80-0471- User Manual
Emerson 1F80-0471– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – WARNING; INSTALLATION; Remove Old Thermostat; WIRING CONNECTIONS
- Page 3 – Home Screen Description; THERMOSTAT QUICK REFERENCE; Programming and Confi guration Items
- Page 4 – Select Reversing Valve Output; INSTALLER/CONFIGURATION MENU
- Page 6 – OPERATING YOUR THERMOSTAT; Set Current Time and Day; PROGRAMMING (For Programmable Model Only)
- Page 8 – TROUBLESHOOTING; Reset Operation
- Page 9 – Una sola etapa o bomba de calor; APLICACIONES; GUÍA DE APLICACIÓN DEL TERMOSTATO; ESPECIFICACIONES; ATENCIÓN: AVISO SOBRE EL CONTENIDO DE MERCURIO; Índice Página; ¡Conserve estas instrucciones para
- Page 10 – INSTALACIÓN; Figura 2 – Base y vista posterior del termostato; Retire el termostato viejo; Antes; No; Instalación del termostato nuevo; Figura 1 – Puerta del compartimiento de las pilas abierta; Pilas; CONEXIONES ELÉCTRICAS
- Page 11 – Descripción de la pantalla principal; GUÍA DE REFERENCIA RÁPIDA DEL TERMOSTATO; Elementos de programación y confi guración
- Page 12 – MENÚ INSTALADOR/DE CONFIGURACIÓN; Selección de salida de válvula inversora
- Page 14 – CÓMO USAR EL TERMOSTATO; Operación manual para modo no programable; PROGRAMACIÓN (sólo para el modelo programable)
- Page 15 – Planilla de cálculo para la reprogramación a 5/2 días y 5+1+1 días
- Page 16 – SOLUCIÓN DE PROBLEMAS; Operación de reajuste
Index
Page
Installation
2
Wiring Connections
2
Thermostat Quick Reference
3
Installer Confi guration Menu
4
Operating Your Thermostat
6
Programming
6
Troubleshooting
8
Save these instructions for future use!
Description
Gas or Oil Heat
Yes
Electric Furnace
Yes
Heat Pump (No Aux. or Emergency Heat)
Yes
Heat Pump (with Aux. or Emergency Heat)
No
Systems with up to 3 Stages Heat, 2 Stages Cool
No
Heat Only Systems
Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces
Yes
Cool Only Systems
Yes
Hydronic (Hot Water) Zone Heat – 2 Wires
Yes
Hydronic (Hot Water) Zone Heat – 3 Wires
Yes
Blue Single 1/1 Stage Ther mostat with
Automatic Heat/Cool Changeover Option
PART NO. 37-6749D
Replaces 37-6749C
0902
Single Stage or Heat Pump
Installation and Operating Instructions for Model:
APPLICATIONS
THERMOSTAT APPLICATION GUIDE
1F80-0471 Thermostat
SPECIFICATIONS
Electrical Rating:
Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45° to 90°F (7° to 32°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) . . . . . . . . . . . . . . . . . . . . . Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient . . . . . . . . . . . . . . . . . . . . . . . . . . 32° to +105°F (0° to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . . -4° to +150°F (-20° to +65°C)
Dimensions Thermostat . . . . . . . . . . . . . . . . . . . . . . 3.4"H x 4.4"W x 1.3"D
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to
www.white-rodgers.com
for location to
send product containing mercury.
Model
Programming
Choices
1F80-0471
5/2 Day 5/1/1 Day Non-Programmable
1F86-0471
Non-Programmable
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
www.white-rodgers.com
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Emerson 1F80-0471
Summary
Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code. WARNING ! INSTALLATION Remove Old Thermostat A standard heat/cool thermostat consists of three basic parts:1. The cover, which may be either a snap-on or hinge type.2. The base, whic...
3 Time Day of Week SettingTemperature RoomTemperature Temperature Up/Down HOLD Button SYSTEMButton FANButton SYSTEMIndicator FANIndicator MENU/SCHEDULE/RUNButton Displays the power level of the 2 "AA" batteries: indicates good power level. indicates batteries at abouthalf power. “ Change ” i...
4 INSTALLER/CONFIGURATION MENU With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the next menu item. Press or to change an item option. Shaded items are not available on...