Emerson 1F80-0471- User Manual

Emerson 1F80-0471

Emerson 1F80-0471– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – WARNING; INSTALLATION; Remove Old Thermostat; WIRING CONNECTIONS
  • Page 3 – Home Screen Description; THERMOSTAT QUICK REFERENCE; Programming and Confi guration Items
  • Page 4 – Select Reversing Valve Output; INSTALLER/CONFIGURATION MENU
  • Page 6 – OPERATING YOUR THERMOSTAT; Set Current Time and Day; PROGRAMMING (For Programmable Model Only)
  • Page 8 – TROUBLESHOOTING; Reset Operation
  • Page 9 – Una sola etapa o bomba de calor; APLICACIONES; GUÍA DE APLICACIÓN DEL TERMOSTATO; ESPECIFICACIONES; ATENCIÓN: AVISO SOBRE EL CONTENIDO DE MERCURIO; Índice Página; ¡Conserve estas instrucciones para
  • Page 10 – INSTALACIÓN; Figura 2 – Base y vista posterior del termostato; Retire el termostato viejo; Antes; No; Instalación del termostato nuevo; Figura 1 – Puerta del compartimiento de las pilas abierta; Pilas; CONEXIONES ELÉCTRICAS
  • Page 11 – Descripción de la pantalla principal; GUÍA DE REFERENCIA RÁPIDA DEL TERMOSTATO; Elementos de programación y confi guración
  • Page 12 – MENÚ INSTALADOR/DE CONFIGURACIÓN; Selección de salida de válvula inversora
  • Page 14 – CÓMO USAR EL TERMOSTATO; Operación manual para modo no programable; PROGRAMACIÓN (sólo para el modelo programable)
  • Page 15 – Planilla de cálculo para la reprogramación a 5/2 días y 5+1+1 días
  • Page 16 – SOLUCIÓN DE PROBLEMAS; Operación de reajuste
Loading the manual

Index

Page

Installation

2

Wiring Connections

2

Thermostat Quick Reference

3

Installer Confi guration Menu

4

Operating Your Thermostat

6

Programming

6

Troubleshooting

8

Save these instructions for future use!

Description

Gas or Oil Heat

Yes

Electric Furnace

Yes

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with Aux. or Emergency Heat)

No

Systems with up to 3 Stages Heat, 2 Stages Cool

No

Heat Only Systems

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

Blue Single 1/1 Stage Ther mostat with

Automatic Heat/Cool Changeover Option

PART NO. 37-6749D

Replaces 37-6749C

0902

Single Stage or Heat Pump

Installation and Operating Instructions for Model:

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

1F80-0471 Thermostat

SPECIFICATIONS

Electrical Rating:

Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC

Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45° to 90°F (7° to 32°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) . . . . . . . . . . . . . . . . . . . . . Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient . . . . . . . . . . . . . . . . . . . . . . . . . . 32° to +105°F (0° to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . . -4° to +150°F (-20° to +65°C)
Dimensions Thermostat . . . . . . . . . . . . . . . . . . . . . . 3.4"H x 4.4"W x 1.3"D

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.

Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to

www.white-rodgers.com

for location to

send product containing mercury.

Model

Programming

Choices

1F80-0471

5/2 Day 5/1/1 Day Non-Programmable

1F86-0471

Non-Programmable

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.

www.white-rodgers.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Emerson 1F80-0471

Summary

Page 2 - WARNING; INSTALLATION; Remove Old Thermostat; WIRING CONNECTIONS

Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code. WARNING ! INSTALLATION Remove Old Thermostat A standard heat/cool thermostat consists of three basic parts:1. The cover, which may be either a snap-on or hinge type.2. The base, whic...

Page 3 - Home Screen Description; THERMOSTAT QUICK REFERENCE; Programming and Confi guration Items

3 Time Day of Week SettingTemperature RoomTemperature Temperature Up/Down HOLD Button SYSTEMButton FANButton SYSTEMIndicator FANIndicator MENU/SCHEDULE/RUNButton Displays the power level of the 2 "AA" batteries: indicates good power level. indicates batteries at abouthalf power. “ Change ” i...

Page 4 - Select Reversing Valve Output; INSTALLER/CONFIGURATION MENU

4 INSTALLER/CONFIGURATION MENU With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the next menu item. Press or to change an item option. Shaded items are not available on...

Other Emerson Models