97749C (Rev. J - 7/07)

ECDFPW314C ECDFPWVR314C

Installation/Care/Use Manual

Soft Sides

Fountains with FLEXI-GUARD

®

To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

FIG. 2

FIG. 1

ECDFPW314C

Installer

NOTE: WATER FLOW

DIRECTION

BUILDING WATER
INLET

SERVICE STOP
(NOT FURNISHED)

1/4" O.D. TUBE
WATER INLET
TO COOLER

3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - NOTE: REINFORCE THE WALL IN THE SHADED AREAS

97749C (Rev. J - 7/07) ECDFPW314C ECDFPWVR314C FIG. 3 PAGE 2 LEGENDA = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUBBED 1-1/2" (38mm) FROM WALL SHUT OFF BY OTHERSB = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAINC = 1-1/4" DRAIN FURNISHEDD = OPENIN...

Page 3 - INSTALLATION INSTRUCTIONS; If supply pressure varies greatly; TROUBLE SHOOTING AND MAINTENANCE

97749C (Rev. J - 7/07) ECDFPW314C ECDFPWVR314C PAGE 3 INSTALLATION INSTRUCTIONS 1 . Wall should already be framed for the fountain using the positioning dimensions shown in Figure 3. Shown dimensions pertain to installation location (framing must support up to 300 lbs. weight). These dimensions are ...

Page 4 - SEE

97749C (Rev. J - 7/07) ECDFPW314C ECDFPWVR314C PAGE 4 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 PART NO. ITEM NO. PARTS LIST Drain - StrainerRetaining NutPush ButtonPush Button SleeveRegulator...