Installation/Care/Use Manual

Soft Sides

™

Refrigerated Fountains with FLEXI-GUARD

®

To assure you install this model easily and correctly,

PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE

INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH

PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave

these instructions inside the fountain for future reference.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO

WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY

OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK

INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN

INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING

THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER

SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING

PLUMBING SYSTEM.

13

14

42

FIG. 2

FIG. 1

Installer

NOTE: WATER FLOW

DIRECTION

BUILDING WATER

INLET

SERVICE STOP

(NOT FURNISHED)

1/4" O.D. TUBE

WATER INLET

TO COOLER

3/8" O.D. UNPLATED

COPPER TUBE CONNECT

COLD WATER SUPPLY

42

SEE FIG. 7

ERO28C

ERO28RAC

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FIG; LEGEND A

97114C (Rev. F - 01/01) ERO28C*B ER028RAC*B PAGE 2 FIG . 3 LEGEND A = 3/8" O.D. TUBE CONNECT (CHILLER W ATER OUTLET) B = 3/8" O.D. TUBE CONNECT (CHILLER W ATER INLET) SHUT OFF V A LVE BY OTHERS C = 1-1/4" TRAP FURNISHED D = ELECTRICAL INLET ERO28C ERO28RAC

Page 3 - INSTALLATION INSTRUCTIONS

97114C (Rev. F - 01/01) ERO28C*B ERO28RAC*B PAGE 3 FIG. 4 INSTALLATION INSTRUCTIONS 16 40 FIG. 5 1. Install mounting frame. See mounting frame instructions. 2. Install remote chiller. Remove front panel of chiller. Slide chiller onto the shelf and position it to the left within the guides on the she...

Page 4 - TROUBLE SHOOTING AND MAINTENANCE

97114C (Rev. F - 01/01) ERO28C*B ER028RAC*B PAGE 4 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 PART NO. ITEM NO. PARTS LIST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 2...