Page 3 - Table of contents
3 Contents Page no For the user Your new appliance ...................................................................................... 2 Safety information ........................................................................................ 4 Description of the product ..........................
Page 4 - Safety information
4 Safety information These warnings are provided in the interests of your safety. Ensure you fully understand them before installing or using the appliance. Your safety is of paramount importance. If you are unsure about the meaning of these warnings contact the Customer Care Department for assistan...
Page 5 - Description of the product
5 Description of the product Burner Control knob Air intake Air intake The primary air intake aperture mustnever be blocked by objests of any kindat any time.
Page 6 - Operations
6 Burner markings Symbols at each control knob indicates which burner is adjusted with the control knob. Front Burner Back burner Panel markings Each control knob has a ring showing the scale of markings. Off. Maximum flame Minimum flame Operations
Page 8 - Ignition
8 1. Depress and turn the control knob for the burner to the left to max. flame . (Ignition position)2. The ignition electrode will emit sparks, and when the mixture of gas and air is correct, the burner will be ignited. If it is not possible to connect the unit to mains, a match may be used to igni...
Page 9 - Maintenance and cleaning
9 Maintenance and cleaning For reasons of hygiene and safety, the cooking zones must be kept clean. Grease stains and spilled food generate smoke when heated, and can even cause fire. Splashguard The splashguard can be removed to make it easier to clean the surface. What to do:1. Hold the splashguar...
Page 12 - Technical data
12 N L1 240 V1N + PE Type of gas Adjusted to natural gas: G20-20 mbar Category and pressures UK: II2H3+ 20 mbar - 28/37 mbar Max. nominal load Q na H S : Medium sized burner = 1,9 kW x 1 Large sized burner = 2,7 kW x 1 Total= 4,6 kW FSD The unit features fully-secured gas taps (thermo-fuse). H S = T...
Page 13 - Important safety requirements
13 This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 68...
Page 15 - Mounting
15 Caution: In order to avoid a hazard this appliance must be installed according to these instructions for installation The hob unit can be mounted in any type of kitchen with a table surface whose thickness is between 28 mm and 40 mm. Headroom The distance to any shelves or tops of a cabinet under...
Page 19 - Something not working
19 Something not working If the hob is not working correctly, please carry out the following checks before contacting your local AEG Service Force Centre. IMPORTANT: If you call out an engineer to a fault caused by incorrect use or installation, a charge will be made even if the hob is under guarant...
Page 20 - Service & spare parts
20 In the event of your appliance requiring service, or if you wish to purchase spare parts, contact your local AEG Service Force Centre by telephoning: 08705 929 929 Your call will automatically be routed to the Service Centre covering your post code area. In-guarantee customers should ensure that ...
Page 21 - Guarantee conditions
21 AEG offer the following guarantee to the first purchaser of this appliance:1. The guarantee is valid for 12 months commencing when the appliance is handed over to the first retail purchaser, which must be verified by purchase invoice or similar documentation.2. The guarantee covers all parts or c...