Rev. 2.0 10/24/2000

EV Dx38 Digital Parameters

Dx38 OS Rev.: 0.90

File: Dx38 Form

Loudspeaker System

Xi-1123A TriAmp 3-way

Xi-1123A BiAmp 3-way

Notes

Conventional Active TriAmp 3-way, no overlap

Conventional BiAmp 3-way, passive Mid/Hi, no overlap

Un-hide cells for revision history When using with Sub, change LO HiPass to LR24 @ 90Hz.

When using with Sub, change LO HiPass to LR24 @ 90Hz.

and specific system notes. Out 2 (Mid) Delay @ 21uS.

Change OUT 2 (Mid/Hi) Delay to 208uS.

Out 3 (HI) Delay @ 104uS.

Programmer: 1st Rev. - Last Rev. Steve Jakowski 03JUN04

Steve Jakowski 03JUN04

Frequency Band

FR

FR

LO

MID

HI

FR

FR

LO

MID/HI

Connector

IN 1

IN 2

OUT 1 OUT 2 OUT 3 OUT 4

IN 1

IN 2

OUT 1 OUT 2 OUT 3 OUT 4

Input Source Routing

IN 1

IN 1

IN 1

IN 1

IN 1

Filter 1 Type

PEQ

PEQ Bypass

PEQ

PEQ

Filter 1 Freq.

(Hz)

60

360

*

60

380

Filter 1 Q/Slope

(Q,dB/Oct)

2.0

2.8

*

2.0

3.0

Filter 1 Level

(dB)

+6

-4

*

+6

-4

Filter 2 Type

PEQ

PEQ LOSLV

PEQ

PEQ

Filter 2 Freq.

(Hz)

250

500

1.64K

250

500

Filter 2 Q/Slope

(Q,dB/Oct)

2.0

4.0

6dB

2.0

3.5

Filter 2 Level

(dB)

+5

+2

-3

+5

+2

Filter 3 Type

Bypass PEQ

PEQ

Bypass PEQ

Filter 3 Freq.

(Hz)

*

960

5.4K

*

1.0K

Filter 3 Q/Slope

(Q,dB/Oct)

*

4.0

5.0

*

2.0

Filter 3 Level

(dB)

*

-2

-4

*

-4

Filter 4 Type

Bypass PEQ

HISLV

Bypass PEQ

Filter 4 Freq.

(Hz)

*

3.0K

6.3K

*

5.0K

Filter 4 Q/Slope

(Q,dB/Oct)

*

4.0

6dB

*

2.0

Filter 4 Level

(dB)

*

-12

+3

*

-4

Filter 5 Type

Filter 5 Freq.

(Hz)

Filter 5 Q/Slope

(Q,dB/Oct)

Filter 1 Level

(dB)

HP Resp

(Type,dB/Oct)

BW24 LR24

LR24

BW24 LR24

HP Frequency (Hz)

50

250

1.64K

50

250

HP Polarity (Norm/Inv)

NORM NORM NORM

NORM NORM

LP Resp

(Type,dB/Oct)

LR24

LR24 12Q2.0

LR24 12Q1.5

LP Frequency (Hz)

250

1.64K 16.0K

250

16.0K

LP Polarity (Norm/Inv)

NORM NORM NORM

NORM NORM

Input Delays

(mSec)

1.9

1.9

1.9

1.9

1+2 Input Delay

(mSec)

Output Delay

0

312

396

0

521

Output Delay Unit

uS

uS

uS

uS

uS

Comp Thresh

(dBu)

Comp Ratio

(X:1)

Comp Attack

(mSec)

Comp Release

(mSec)

Limit Thresh

(dBu)

0

-2

-3

0

-2

Limit Release

(mSec)

80

50

50

80

50

Level (dB)

0

-4

-8

0

-5

Polarity (Norm/Inv)

NORM NORM NORM

NORM NORM

Input

0

0

0

0

Output

-6

-6

-6

-6

-6

-6

-6

-6

Knobs

EQ

Filter Block

Crossover

Output

Compres-

sor

Limiter

1.9

1.9

Delay

Assign-