Page 2 - Contents
Design Par 575H™ ©Elation Professional® 2 Design Par 575H™ Contents 1. General Information……………………………………………………………………… 3 a. Introduction………………………………………………………………………. 3 a. Unpacking………………………………………………………..…………..… 3 a. Customer Support…………………………………………….………………… 3 a. Warranty Registration………………………………………………...
Page 3 - General Information; INTRODUCTION
Design Par 575H™ ©Elation Professional® 3 Design Par 575H™ 1. General Information INTRODUCTION : Congratulations, you have just purchased one of the most innovative and reliable lighting fixtures on the market today! The Design Par 575H,™ has been designed to perform reliably for years when the guid...
Page 4 - yourself, doing so will void your manufactures warranty.
Design Par 575H™ ©Elation Professional® 4 Design Par 575H™ yourself, doing so will void your manufactures warranty. Please do not discard the shipping carton in the trash. Please recycle whenever possible. WARRANTY REGISTRAT I O N : The Design Par 575H™ carries a two year (730 days) limited warranty...
Page 5 - replace it immediately with a new one of similar power rating.
Design Par 575H™ ©Elation Professional® 5 Design Par 575H™ This device falls under protection-class 1. Therefore it is essential that the device be grounded properly. All electrical connections must performed by qualified personal. Be sure the available voltage matches the voltage requirements of th...
Page 6 - SAFETY INSTRUCTIONS; Be sure to unplug the DESIGN PAR 575HTM from the power outlet before
Design Par 575H™ ©Elation Professional® 6 Design Par 575H™ 2. SAFETY INSTRUCTIONS The Design Par 575H™ is an extremely sophisticated piece ofelectronic equipment. To guarantee a smooth operation, it isimportant to follow the guidelines in this manual. Themanufacturer of this device will not accept r...
Page 7 - may increase the risk of damage and/or personal injury.; Never look directly into the light source,
Design Par 575H™ ©Elation Professional® 7 Design Par 575H™ may increase the risk of damage and/or personal injury. 10. To reduce the risk of fire or shock, do not expose this fixture to rain or moisture. 11. Do not attempt to operate this fixture if the power cord has become damaged or frayed. Impor...
Page 9 - GENERAL GUIDELINES; This fixture was designed for indoor use only.
Design Par 575H™ ©Elation Professional® 9 Design Par 575H™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, etc. Do not attempt operation or installation without a proper knowledge on how to so. This fixture was designed for ...
Page 10 - ) LAMP SOCKET ASSEMBLY COVER –
Design Par 575H™ ©Elation Professional® 10 Design Par 575H™ 5. FIXTURE OVERVIEW 1) HEAD ASSEMBLY – This assembly holds the lamp, gel holder, lens, and reflector. 2) LAMP SOCKET ASSEMBLY COVER – This cover retains the lamp socket
Page 11 - 0) CARRYING HANDLE –
Design Par 575H™ ©Elation Professional® 11 Design Par 575H™ assembly. Remove this cover to access the lamp. Refer to page 13 for proper lamp replacement. 3) ARM ASSEMBLY – This assembly holds the electronics, motors, and belt that control the unit’s tilt movement. 4) MENU DISPLAY – Four segment LED ...
Page 12 - 5) OMEGA CLAMP SOCKET –
Design Par 575H™ ©Elation Professional® 12 Design Par 575H™ protect the electronics in the event of severer power fluctuations. Never defeat this fuse. In the event of fuse failure, always be sure to replace with an exact match fuse unless other wise specified by an authorized Elation Professional t...
Page 13 - . LAMP INSTALLATION INSTRUCTIONS; Installing or replacing the lamp; Only install the lamp with the device unplugged from the mains.; never touch the lamp when it is hot.; Installation Procedure:; Gently pull out the lamp/socket assembly to access the lamp.
Design Par 575H™ ©Elation Professional® 13 Design Par 575H™ 6 . LAMP INSTALLATION INSTRUCTIONS Installing or replacing the lamp Only install the lamp with the device unplugged from the mains. The lamp has to be replaced when it is damaged or deformed. Before replacing the lamp be sure the unit has a...
Page 14 - Do not operate this device with open cover; Lamp Optimization
Design Par 575H™ ©Elation Professional® 14 Design Par 575H™ 4. Carefully insert the new lamp into the socket (Be sure to only use an approved lamp). Please remember the lamp should fit completely in the lamp socket. 5. Once the lamp has been inserted into the socket, gently slide the socket assembly...
Page 15 - at a time until the light is evenly distributed.
Design Par 575H™ ©Elation Professional® 15 Design Par 575H™ at a time until the light is evenly distributed. 4. If the light is brighter around the edge than it is in the center, or if light output is low, the lamp is too far back in the reflector. "Push” the lamp out by turning each of the adju...
Page 16 - MOUNTING AND INSTALLATION; areas were the fixture might be reached by unauthorized personal.; Before taking into operation for the first time,; Mounting; qualified staff should attempt installation.
Design Par 575H™ ©Elation Professional® 16 Design Par 575H™ 7. MOUNTING AND INSTALLATION Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, or in areas were the fixture might be reached by unauthorized personal. Before mounting the fixture to any surface...
Page 17 - Mounting points; Be sure all electrical connections are performed by a qualified
Design Par 575H™ ©Elation Professional® 17 Design Par 575H™ Mounting points Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material...
Page 18 - power cord to the appropriate wall outlet.; Clamp Mounting
Design Par 575H™ ©Elation Professional® 18 Design Par 575H™ Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet. Clamp Mounting The Design Par 575H™ provides a unique mounting bracket assembly that integrates the hanging yo...
Page 19 - Securing the DESIGN PAR 575HTM
Design Par 575H™ ©Elation Professional® 19 Design Par 575H™ Securing the DESIGN PAR 575H™ Regardless of the rigging option you choose for your DESIGN PAR 575H™ always be sure to secure your fixture with a safety cable. The fixture provides a built-in rigging point for a safety cable on the hanging b...
Page 20 - UNDERSTANDING DMX; and female 3-pin XLR connector on either end of the cable.
Design Par 575H™ ©Elation Professional® 20 Design Par 575H™ 8. UNDERSTANDING DMX Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): Your fixture and your DMX controller require a standard 3-pin XLR connector for data input and data output (see figure below). If you are constru...
Page 21 - DMX-512 control connection; DMX-512 connection with DMX terminator
Design Par 575H™ ©Elation Professional® 21 Design Par 575H™ DMX-512 control connection Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-pin XLR input of the moving head (Please refer to the diagram below.). You can chain multiple movin...
Page 22 - Fixture DMX addressing
Design Par 575H™ ©Elation Professional® 22 Design Par 575H™ Fixture DMX addressing; All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixtu...
Page 23 - signal the display will flash
Design Par 575H™ ©Elation Professional® 23 Design Par 575H™ "A.XXX" (XXX representing the actual DMX address). If the fixture is not receiving a DMX signal the display will flash "A.XXX" (XXX representing the actual DMX address). If your fixture is connected to a DMX controller and t...
Page 25 - Default settings shaded.
Design Par 575H™ ©Elation Professional® 25 Design Par 575H™ 10. FIXTURE MENU On-Board System Menu: The DESIGN PAR 575H™ comes with an easy to navigate system menu. This next section will detail the functions of each command in the system menu. LED Control Panel: The control panel located on the top,...
Page 27 - Main Menu Functions
Design Par 575H™ ©Elation Professional® 27 Design Par 575H™ Main Menu Functions 1. ADDRESS MENU - AOO1 - A511 (Value) - This is where you set the fixtures DMX address. Setting/Changing the DMX Address After applying power to the DESIGN PAR 575H™ the LED will display the fixture’s current DMX address...
Page 28 - RUN
Design Par 575H™ ©Elation Professional® 28 Design Par 575H™ will test the color channel, changing the color one by one and show the rainbow effect with different speeds. Again please remember, there are 8 DMX channels, and all can be tested 4. Press MODE/ENTER or EXIT to exit. 3. PLAY MENU - RUN – T...
Page 29 - Press MODE/ESC to return to the main menu.; ALL; Tap the UP button until “RESE” is displayed, press ENTER.; SCAN
Design Par 575H™ ©Elation Professional® 29 Design Par 575H™ confirm. 5. Press MODE/ESC to return to the main menu. 4. LAMP MENU - – This menu function will manually turn the lamp on and off. Follow the procedure below to enter the lamp menu: 1. Access the main menu. 2. Tap the UP button until “LAMP”...
Page 30 - Please
Design Par 575H™ ©Elation Professional® 30 Design Par 575H™ 1. Access the main menu. 2. Tap the UP button until “RESE” is displayed, press ENTER. 3. Tap the UP button until “SCAN” is displayed, then press ENTER to confirm. 4. The display will show “ON/OFF”. Press the UP button to select “ON” to rese...
Page 33 - V A L U; – This menu option access all the special functions listed below.; LAAU
Design Par 575H™ ©Elation Professional® 33 Design Par 575H™ V A L U – This function will display the DMX value of each channel as it is adjusted through the use of a DMX console. 1. Access the main menu. 2. Tap the UP button until “DISP” is displayed. 3. Press ENTER, the display will show “VALU”. 4....
Page 34 - Fixture Settings
Design Par 575H™ ©Elation Professional® 34 Design Par 575H™ RDMX - Allows DMX address to be changed via and external DMX controller. DLOF - Switch lamp off via DMX controller. DLAY - Lamp-on delay time. SPOT - This provides a spot beam for better lamp optimization. DFSE (Default) - Resets the unit t...
Page 35 - Controller Settings; DLOF
Design Par 575H™ ©Elation Professional® 35 Design Par 575H™ 4. The display will show “ON/OFF.” 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. Controller Settings : 1. Set...
Page 36 - SPOT; When you confirm this function, the fixture will begin to
Design Par 575H™ ©Elation Professional® 36 Design Par 575H™ – This function allows the user to set a lamp “strike” delay time. 1. Access the main menu. 2. Tap the UP button until “SPEC” is displayed, press ENTER. 3. Tap the UP button until “DLAY” is displayed, press ENTER. 4. The display will show “...
Page 37 - FEED
Design Par 575H™ ©Elation Professional® 37 Design Par 575H™ 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function. 6. Press ENTER to confirm. 7. Press MODE/ESC to return to the main menu. FEED - Use this function to activate the pan/tilt error correct...
Page 38 - ADJU; fixture. To enter the calibration menu follow the steps below:; STEP; are at total of 48 steps.
Design Par 575H™ ©Elation Professional® 38 Design Par 575H™ 4. The display will show “V-1.0,” the display may also show, “V-2.0,” “V-9.9” etc. 5. Press ENTER or MODE/ESC to exit. ADJU - This function is used to calibrate the various internal motors in the event the internal homing mechanism become s...
Page 40 - Tap the UP button until “EDIT” is displayed, press ENTER.; Editing procedure 1; Tap the UP button until “EDIT” is displayed and press ENTER.
Design Par 575H™ ©Elation Professional® 40 Design Par 575H™ 5. Press ENTER to save and MODE/ESC to exit. SC01 - This function allows you to choose the total number of scenes in your internal program. 1. Access the main menu. 2. Tap the UP button until “EDIT” is displayed, press ENTER. 3. Tap the UP ...
Page 41 - CEDT
Design Par 575H™ ©Elation Professional® 41 Design Par 575H™ indicates the time needed to run this scene. 10. Press ENTER to edit the time needed, the display shows “ TXXX ” , “ XXX ” represents the time needed to run this scene. For example, “ T002 ” means scene 1 needs 0.4 seconds to run, “ T - 1 5...
Page 42 - which one you want to activate, and press ENTER.
Design Par 575H™ ©Elation Professional® 42 Design Par 575H™ number of steps under Step (S-01- S-48). You can edit the individual scenes under Edit. 1. Access the main menu. 2. Tap the UP button until “EDIT” is displayed, press ENTER. 3. Tap the UP button until “RUN” is displayed, press ENTER. 4. “AU...
Page 43 - CHANNEL 6: Dimmer Control
Design Par 575H™ ©Elation Professional® 43 Design Par 575H™ 11. DMX CHANNEL TRAITS: The chart below details the channel layout for 8 DMX channels (default). In 8bit mode the “Pan Fine” and “Tilt Fine” channels are not used, thus converting the fixture into a 6-channel DMX fixture. CHANNEL 1: Pan Mov...
Page 44 - DMX channel function and values:; Channel 1 – Pan movement 8bit:
Design Par 575H™ ©Elation Professional® 44 Design Par 575H™ DMX channel function and values: Channel 1 – Pan movement 8bit: Channel 2 – Pan fine (16bit only): Channel 3 – Tilt movement 8bit: Channel 4 – Tilt fine (16bit only): Channel 5 – Speed pan/tilt movement: 0~255 Max to min speed Channel 6 – D...
Page 45 - persist after a second attempt a third attempt will be made.
Design Par 575H™ ©Elation Professional® 45 Design Par 575H™ 12. ERROR CODES: When power is applied, the unit will automatically enter a “reset/test” mode. This mode brings all the internal motors to a home position. If there is an internal problem with one or more of the motors an error code will fl...
Page 46 - (defective motor or a defective motor IC drive on the main PCB).
Design Par 575H™ ©Elation Professional® 46 Design Par 575H™ malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure (defective motor or a defective motor IC drive on the main PCB).
Page 47 - CLEANING AND MAINTENANCE; The following points have to be considered during the inspection:
Design Par 575H™ ©Elation Professional® 47 Design Par 575H™ 13. CLEANING AND MAINTENANCE The following points have to be considered during the inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or ...
Page 52 - Circuit Schematic
Design Par 575H™ ©Elation Professional® 52 Design Par 575H™ 17. Circuit Schematic
Page 53 - TECHNICAL SPECIFICATIONS; Fuse protection; Gel Frame Included; DMX Channels; or; Drive
Design Par 575H™ ©Elation Professional® 53 Design Par 575H™ 18. TECHNICAL SPECIFICATIONS Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. Power supplyPower consumption _98VAC, 50Hz; _ 120VAC, 50Hz; _ 208VA...
Page 56 - Elation Professional
Design Par 575H™ ©Elation Professional® 56 Design Par 575H™ Elation Professional 4295 Charter Street Los Angeles, CA. 90058 323-582-3322 / 323-582-3108 fax www.ElationLighting.com / [email protected]