Page 2 - TABLE OF CONTENS; CONTENTS
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 1 www.ElationLighting.com TABLE OF CONTENS CONTENTS 1. General Information……………………………………………………………………… 2 a. Introduction………………………………………………………………………. 2 b. Unpacking………………………………………………………..…………..… 2 c. Customer Support…………………………………………….…………...
Page 3 - GENERAL INFORMATION; use and maintenance.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 2 www.ElationLighting.com 1. GENERAL INFORMATION INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The Design LED 12 Brick II ™, has been designed to perform...
Page 4 - yourself. Doing so will void your manufactures warranty.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 3 www.ElationLighting.com rain or moisture. Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself. Doing so will void your manufactures warranty. Please do not discard the shipping carton in ...
Page 5 - SAFETY INSTRUCTIONS; to allow for proper cooling.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 4 www.ElationLighting.com 2. SAFETY INSTRUCTIONS To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Elation Professional will not accept responsibility for damages resulting from the m...
Page 6 - replace it immediately with a new one of similar power rating.; Never look directly into the light source,
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 5 www.ElationLighting.com sure the power cord is never crimped or damaged. If the power cord is damaged, replace it immediately with a new one of similar power rating. 13. Always disconnect from main power before performing any type of ...
Page 7 - rated LED life
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 6 www.ElationLighting.com 3. FEATURES • Low power consumption • Minimal heat emission • Maintenance free operation • Equipped with 12 one-watt LEDS: (4 red, 4 green, 4 blue) • High power LEDS manufactured by Lumileds, USA • 100,000 hour...
Page 8 - GENERAL GUIDELINES; installation without a proper knowledge on how to do so.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 7 www.ElationLighting.com 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, and other types of architectural installations. Do not attempt operation or installati...
Page 9 - FIXTURE OVERVIEW; angle adjustments have been made.; Lens
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 8 www.ElationLighting.com 5. FIXTURE OVERVIEW 1 2 3 4 5 6 7 8 9 1 0 11 12 13 14 1. Bracket Locking Knob – This knob is used to secure the bracket in place after angle adjustments have been made. 2. Diffusing Lens – This lens is used to ...
Page 10 - and will void your manufactures warranty.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 9 www.ElationLighting.com 4. On/Off Power Switch – Controls main power to the unit. 5. Power Output Jack – Use this jack to jump power to another Design LED 12 Brick II ™ 6. Power Input/Fuse Holder Assembly – This assembly holds the saf...
Page 11 - This button is used to select and confirm a menu function.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 10 www.ElationLighting.com 14. ENTER BUTTON – This button is used to select and confirm a menu function.
Page 12 - MOUNTING AND INSTALLATION; fixture, refer to the illustration below.; qualified staff should attempt installation.; Mounting points
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 11 www.ElationLighting.com 6. MOUNTING AND INSTALLATION Yoke Assembly – Single Unit Operation (DLED 12 Brick shown for illustration purposes only). The device can be placed directly on the stage floor or rigged in any orientation on a t...
Page 13 - power cord to the appropriate wall outlet.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 12 www.ElationLighting.com Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all instal...
Page 14 - Clamp Mounting; See illustration below.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 13 www.ElationLighting.com CAUTION! Be sure all electrical connections are performed by a qualified electrician before attempting any operation. Clamp Mounting The Design LED 12 Brick II ™ provides a unique mounting bracket assembly tha...
Page 15 - Securing the Design LED 12 Brick II TM; Always secure your fixture with a safety cable when
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 14 www.ElationLighting.com Securing the Design LED 12 Brick II ™ Always secure your fixture with a safety cable when suspend-ing the unit from truss or other means. The fixture provides a built-in rigging point for a safety cable as ill...
Page 16 - UNDERSTANDING DMX; and female 3-pin XLR connector on either end of the cable.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 15 www.ElationLighting.com 7. UNDERSTANDING DMX Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): Your fixture and your DMX controller require a standard 3-pin XLR connector for data input and data output (see fi...
Page 17 - CON TR OL LE R; DMX-512 connection with DMX terminator
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 16 www.ElationLighting.com 4™ or DMX Branch/4™. CON TR OL LE R Please note: to ensure maximal stability, only two devices may be connected together in this manner! From the third devices, please connect to power supply to get power for ...
Page 18 - page details a proper cable conversion.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 17 www.ElationLighting.com 5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR co...
Page 19 - DMX Mode
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 18 www.ElationLighting.com 8. OPERATING MODES This fixture can run in three different DMX modes, the following pages will detail the different operating modes as well as how to achieve the different operating modes. DMX Settings: The ch...
Page 20 - Display menu; MODE; ALON; MANU
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 19 www.ElationLighting.com 224---255 Open If running the internal program, the tailender channel would be the speed of grogram from slow to fast. If not running the internal program, the tailender channel would be dimmer channel. 2 : Di...
Page 21 - SOND; MOD1 Select; OTHR
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 20 www.ElationLighting.com FADE XXX Adjust speed of fade STRB XXX Adjust speed of strobe SPED XXX Adjust speed of scene FADE XXX Adjust speed of fade CHS7 STRB XXX Adjust speed of fade SPED XXX Adjust speed of scene FADE XXX Adjust spee...
Page 22 - reset the fixture you must turn the power off.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 21 www.ElationLighting.com DMX Operation Notes: The fixture will automatically function in DMX mode whenever the unit receives a DMX signal. Please note that this will override all manual settings regardless of dipswitch positions. This...
Page 23 - DMX CHANNEL TRAITS
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 22 www.ElationLighting.com 9. DMX CHANNEL TRAITS 4 Channel Mode: This chart details a simple layout of the DMX channel assignment in 4-channel mode. The chart traits will vary slightly for 3-channel, 12-chennel, and 15-channel operation...
Page 24 - DMX channel’s functions and their values (4 Channel Mode):
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 23 www.ElationLighting.com DMX channel’s functions and their values (4 Channel Mode): Channel 1 - Red: 0-255 Red (0-Black, 255-100% Red) Channel 2 - Green: 0-255 Green (0-Black, 255- 100% Green) Channel 3 - Blue: 0-255 Blue (0-Black, 25...
Page 25 - CLEANING AND MAINTENANCE; sediments. Never remove the ground prong from the power cable.
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 24 www.ElationLighting.com 10. CLEANING AND MAINTENANCE The consider the following point during normal service and inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during norm...
Page 28 - PHOTOMETRIC DATA; Int e nsit y; B e a m a n g l e 4 4
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 27 www.ElationLighting.com 12. PHOTOMETRIC DATA 0 1 2 3 0 0 .8 1.6 1 4 4 4 8 0 7 6 2 . 4 Di stan ce ( m )Di a me t e r ( m ) Int e nsit y LUX ( ) B e a m a n g l e 4 4 °
Page 29 - DIMENSIONAL DRAWINGS
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 28 www.ElationLighting.com 15. DIMENSIONAL DRAWINGS 14. CHANGE LENS TO GET DIFFERENT BEAM ANGLES
Page 30 - CIRCUIT SCHEMATIC
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 29 www.ElationLighting.com 15. CIRCUIT SCHEMATIC
Page 31 - TECHNICAL SPECIFICATIONS
Design LED 12 Brick II ™ ©Elation Professional, Los Angeles Ca. 30 www.ElationLighting.com 16. TECHNICAL SPECIFICATIONS Power supply: 100V~240V AC, 50Hz~60Hz Power consumption: MAX 30w LED Configuration: 12 1Watt Units (4 x Red, 4x Green 4 x Blue) Packing dimensions: 47x26.5x16cm (57x47x36cm ~ 4pc s...
Page 32 - Elation Professional