Ei Electronics Ei 405C - Manual
Ei Electronics Ei 405C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Figure 1a
- Page 3 – (Program units if nearby systems are like-
- Page 4 – LOCATING YOUR SMOKE ALARM; single; Smoke Alarm will give some protection; require; two or; Single Storey Dwelling.
- Page 5 – Figure 2; : Single storey dwelling; Multi Storey Dwellings; : Multi Storey Dwelling
- Page 6 – POSITIONING YOUR SMOKE ALARM; Wall Mounting; Figure 5
- Page 8 – INSTALLING YOUR SMOKE ALARMS; Select a location complying with the above advice.; LOOKING AFTER YOUR SMOKE ALARMS; Manually Testing your Smoke Alarm; Figure 7
- Page 11 – house coding; your Smoke Alarms you must also
- Page 13 – without; the red; Dust & Insect Contamination; The entire Smoke Alarm must be replaced if:-
- Page 14 – Do not put the Smoke Alarm; HARDWIRE INTERCONNECTION; Figure 9
- Page 15 – Lift the wiring cover on the mounting plate as shown in fig 9.; IMPORTANT SAFEGUARDS; ¥ Please read all instructions.
- Page 16 – Limitations of Smoke Alarms
- Page 17 – PLANNING YOUR ESCAPE ROUTE FOR; NEVER
- Page 18 – FIRE SAFETY HINTS; Discard oily or flammable rags.; OPTICAL OR IONISATION ?; dual; tection install each type.
- Page 19 – If your home has more than one floor, at least one alarm; GETTING YOUR SMOKE ALARM SERVICED; AICO; Mile End Business Park,
- Page 20 – TECHNICAL SPECIFICATION
- Page 21 – RF RECEPTION; It silences its horn for ten minutes
- Page 22 – connected with 2 core cable to
1
WARNING
DO NOT INSTALL THE ACTUAL
SMOKE ALARM IN NEW OR
RENOVATED BUILDINGS UNTIL ALL
WORK IS COMPLETED (INCLUDING
FLOOR COVERINGS) AND
BUILDING HAS BEEN FULLY
CLEANED.
(Excessive dust & debris from building work can
contaminate the smoke chamber and cause
problems).
An installed smoke alarm must be removed or
covered fully (with a plastic bag or similar)
before renovations begin.
'Ei Electronics 2003
P/N B15026 R0
RADIO SMOKE ALARMS
with WIRELESS INTERCONNECT
INSTRUCTION LEAFLET
Contains vital information on unit operation and installation.
Read and retain carefully. If you are just installing the unit, this
leaflet
MUST
be given to the householder.
MODELS:
Ei 405
- Replaceable 9V Battery
Ei 405C
- Replaceable 9V Battery &
hard wired interconnect option
Ei 405TY
- 10 Year Lithium Batteries built-in
Ei 405TYC
- 10 Year Lithium Batteries built-in
& hard wired interconnect option
All with Optical Smoke Sensor
1
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
1. READ THIS FIRST A Smoke Alarm is an early warning device. Used correctly itcan give you and your family valuable extra time to escape. ¥ Models Ei405 & Ei405C - connect battery snaps firmly (see fig 1b). Press the test button and horn should sound. ¥ Models Ei405C, Ei405TY & Ei405TYC - sl...
3 ¥ If the Alarm beeps without the red light flashing at the same time then clean unit as this is the automatic test fea-ture indicating the chamber is degraded. ¥ Plan your escape route. ¥ Proper protection usually requires more than one Smoke Alarm. ¥ If you have any doubt or query about Smoke Ala...
4 excellent, particularly at night, as it rapidly identifies wherethe fire is located. This is ideal for larger systems as the dis-turbance in the house can be kept to a minimum e.g. no needto enter all the bedrooms to check to see if the red light isflashing rapidly. 3. LOCATING YOUR SMOKE ALARM Su...