Model

Ei 100TYC Ionisation

High sensitivity

– responds to all standard fires

Dual Ionization chamber - quick response fast
flaming fires

Lithium 10 year battery to provide long lasting life

No changing of battery required

Interconnect up to 12 other alarms

Needs no wiring

Built in sounder

Test and hush button

Kitemarked to BS EN 14604:2005

5 year guarantee


Product Description

The Ei100TYC is an Ionisation Smoke Alarm that runs
on a 9V lithium 10 year battery (supplied with the alarm).

Ionisation smoke alarms operate on the principle that
electrical current flowing between electrodes in an
ionization chamber is reduced when smoke particles
enter.

Ionisation technology gives a rapid response to fast
flaming fires

The Ei100TYC is easily installed and comes supplied
with all necessary screw fixings.

The interconnect feature allows the alarm to be
connected with up to 12 other similar alarms.

Operation

The smoke detector will activate the built in sounder
upon sensing smoke particles

The smoke detector will automatically reset itself
and silence the sounder when smoke particles are
no longer present in the sensing chamber

The built in sounder will provide a minimum sound
output of 85dB at 3m

The “Hush/Test” button will perform a self test and
sound the horn (it may take up to 10 seconds)

The “Hush/Test” button will silence nuisance alarms

Interconnect up to 12 other alarms (9V ionisation,
optical or heat) when one senses smoke, all alarm.
Helps ensure warning will be heard throughout the
house

The smoke detector will emit a beep every 40
seconds to indicate that the battery back up is
depleted and that the alarm should be removed and
replaced with a new one (the batteries are not
replaceable in the Ei100TYC)