Edelbrock 91007 - Manual

Edelbrock 91007

Edelbrock 91007 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 2 – Ta b l e o f C o n t e n t s; SYSTEM INSTALLATION
  • Page 3 – SYSTEM OPERATION
  • Page 4 – I n c l u d e d P a r t s; Your QwikData Basic Package should include the following items:
  • Page 6 – I n s t a l l a t i o n o f t h e Q w i k D a t a D a t a L o g g e r U n i t :; Five pressure sensors are available in pressure ranges:; Te m p e r a t u r e S e n s o r s
  • Page 7 – T K - 4 T h e r m o c o u p l e C o n v e r t e r I n s t a l l a t i o n; Sensor; W i r i n g H a r n e s s I n s t a l l a t i o n a n d C o n n e c t i o n
  • Page 8 – A d v a n c e d D r a g R a c i n g P a c k a g e S e n s o r C o n n e c t i o n s
  • Page 9 – Connection To Battery Power
  • Page 10 – The QwikData CD ROM startup screen will be displayed.
  • Page 12 – Initializing the QwikData Setup; Highlight the file named “default.sup” and click the “OK” button.
  • Page 13 – S e n s o r C a l i b r a t i o n; QwikData configuration is performed in the “Setup” menu:; NOTE
  • Page 14 – D i g i t a l C h a n n e l S e t u p; 4 Absolute maximum; Digital lnputs
  • Page 15 – L o g i c s i g n a l; of a signal. The units for frequency are Hz x 100.
  • Page 16 – R P M E x a m p l e
  • Page 17 – Calib Value; B r a k e O n / O f f E x a m p l e
  • Page 18 – I n j e c t o r O n Ti m e E x a m p l e; See; “Advanced Options”; Lap Beacon Example; In most cases for racing applications, we are; C h a n n e l E n a b l e
  • Page 19 – C h a n n e l N a m e a n d U n i t s
  • Page 20 – Z e r o A n a l o g C h a n n e l s; use the “
  • Page 21 – Z e r o A c c e l e r o m e t e r s; N o t e : T h e Q w i k D a t a u n i t m u s t b e p o w e r e d u p a n d c o n n e c t e d t o y o u r P C .; L o g g i n g S e t u p; This is the; S a m p l e s / Av e r a g e; The Run Time can be calculated from the following formula:
  • Page 22 – S p e e d C h a n n e l
  • Page 23 – Digital Starting Triggers
  • Page 24 – Stopping Trigger
  • Page 25 – Digital Outputs; utilized by checking the appropriate box.; Graphing Setup
  • Page 26 – Channel Colors; If
  • Page 27 – C h a r t S e t u p
  • Page 28 – S a v e S e t u p
  • Page 29 – Load Setup; Load Setup” from the “File” menu.; Download Setup
  • Page 31 – Reset Memory; If you wish to look at different channels than initially selected:; You must; S e t t i n g t h e W i n d o w W i d t h
  • Page 32 – U p l o a d i n g D a t a; “Historical Data” in the “View” menu in the main toolbar.
  • Page 33 – Measuring the Length of Time Between Events
  • Page 34 – Changing the channels Displayed
  • Page 35 – V i e w i n g D a t a a s L a p D e p e n d e n t o r C u m u l a t i v e
  • Page 36 – S c r o l l o r P a n t h e G r a p h
  • Page 37 – The; “Secondary File”; on the lap you wish to overlay.; Aligning Primary and Secondary File Graphs; lap data will automatically align properly.
  • Page 38 – Hint
  • Page 39 – Alternately, you can select “Align Data Files” from the “Graph” menu.
  • Page 40 – Cropping Data Files
  • Page 41 – Obtaining a Histogram
  • Page 42 – E x p o r t D a t a F i l e t o Tex t F i l e
  • Page 43 – Restore Default Setup; Normally you will not ever have to “Restore Defaults”.; Update Firmware
  • Page 44 – C o n n e c t o r P i n O u t : B r a c k e t / I m p o r t a n d C o m p a c t D r a g R a c i n g S y s t e m s
  • Page 45 – P i n A s s i g n m e n t s , M a x i m u m C o n f i g u r a t i o n
  • Page 46 – Q w i k D a t a J u m p e r C o n f i g u r a t i o n; Basic, Bracket and Import Drag Race Packages
  • Page 47 – S e n s o r a n d O p t i o n P a r t N u m b e r s
  • Page 48 – Edelbrock Corporation • 2700 California Street • Torrance, CA 90503
Loading the manual

This QwikGuide manual has been included to provide all the information you need to get your QwikData
Package installed and running quickly and easily.

For more detailed information about the QwikData system, refer to the QwikData Reference Manual on the
QwikData CD ROM.

Catalog #91001 - Basic Package

Catalog #91003 - Bracket Drag Racing Package

Catalog #91004 - Advanced Drag Racing Package

Catalog #91005 - Import / Compact Drag Racing Package

Catalog #91007 - Circle Track / Road Racing Package

Catalog #91009 - Advanced Pro System Package

EDELBROCK QWIKDATA SYSTEMS

Edelbrock Corporation • 2700 California Street • Torrance, CA 90503

EFI Tech Line: 800-416-8628, Option 3 • E-Mail: [email protected]

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Ta b l e o f C o n t e n t s; SYSTEM INSTALLATION

Ta b l e o f C o n t e n t s SYSTEM INSTALLATION Included Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Basic Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Page 3 - SYSTEM OPERATION

Digital Stopping Triggers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Analog Stopping Triggers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 4 - I n c l u d e d P a r t s; Your QwikData Basic Package should include the following items:

Page 1 of 44 Catalog #91001, 91003, 91004, 91005, 91007, 91009Rev. 2/06 - RS/mc ©2006 Edelbrock Corporation Brochure #63-0282 SYSTEM INSTALLATION I n c l u d e d P a r t s Unpack all the parts supplied with the package and verify that there are no parts missing. B a s i c P a c k a g e # 9 1 0 0 1 Y...

Other Edelbrock Models

All Edelbrock Other