NOTE:

Please consult the Edelbrock System Installation

Instructions for the proper way to interact safely with Nitrous

Oxide. Please take all safety precautions when working on any

nitrous oxide injection system.

WARNINGS:

USE ONLY Teflon sealant for all tapered pipe threads.
No sealant is required on AN flare fittings. Do not use

any oil on threads.

This gauge is supplied with a special restrictor fitting

that

must

be installed on the braided line leading to

the nitrous gauge.

USE ONLY -4AN Teflon lined high-pressure stainless

steel-braided line when installing this gauge. All

fittings must have a minimum working pressure of

2000 psi.

Mechanical Section

1. If you are not familiar with nitrous oxide systems and

their installations, do not install this gauge. Have a

qualified technician install it for you.

2. Determine where the nitrous gauge will be mounte d

and the source of the pressure (bottle outlet or nitrous

solenoid inlet fitting). Then determine the length of

steel-braided line required. This line must be purchased

due to the vast number of applications this gauge is

used in.

3. Secure the -4AN sta inless steel- braided line to the back

of the gauge using included female fitting.

4. Install gauge in desired location. Gauges can be

mounted in under dash panels or on window cowling.

Mounting cups can also be used (Auto Meter #3203 or

#3204). Secure gauge with mounting bracket provided.

5. Make sure the nitrous bottle valve is closed and all lines

are free of pressure.

6. Secure an in-line gauge adapter (not supplied) in a

vice . Install the special restrictor fitting (supplied with

gauge) in the in-line gauge adapter. Be sure to use

liquid Teflon sealant on all tapered pipe threads for a

good seal. No sealant is required on AN fittings. Do

not over tighten as this may result in stripped threads

or a broken fitting.

7. Remove the main nitrous feed line from the bottle or

the nitrous solenoid. Install the in-line gauge adapter

with the special restrictor fitting either on the nitr ous

bottle or nitrous solenoid. Re-install the main nitrous

feed line. Install the braided line from the nitrous

gauge to the restrictor fitting.

8. Reconnect all lines.

9. Open the nitrous bottle valve and check for leaks.

Edelbrock Nitrous Systems
Installation Instructions

P/N 73802 - 2 5/8” Nitrous Pressure Gauge

-4AN fitting with wrench flat.

(Use caution, do not over tighten)

Black - Good Ground

White - To Dash 12V(+) Lighting

Steel-braided line to

gauge

Special Restrictor Fitting

(included)

Nitrous

Solenoid

IN OUT

In-Line

Gauge Adapter

Steel-braided line

to gauge

Nitrous Bottle

In-Line Gauge

Adapter

Special Restrictor Fitting

(included)

Use Teflon Sealing

Compound where
symbol indicates.

(Tape not

recommended on

these threads)

Main Nitrous Feed