Part Number

Technische Informationen
Engineering Data Sheet
Informations techniques

P 64

Digital Audio Matrix

Beschreibung

Description

Description

Der P 64 ist eine modulare, ver-
netzbare Audio Matrix inklusive
Signal-Processing, Systemüber-
wachung und Fernbedienbarkeit.
Über 4 Steckplätze kann das Sys-
tem durch jeweils 8-kanalige Audio-
Eingangs- bzw. Ausgangskarten
den eigenen Anforderungen ange-
passt werden. Der P 64 besitzt eine
integrierte Selbstüberwachung und
unterstützt Havarie/Redundanz-
Konzepte in sicherheitsrelevanten
Anlagen. Die lokal gespeicherte
Konfiguration und Parameter sind
komplett abrufbar.

The P 64 is a modular, network-
compatible audio matrix including
signal processing, system monitor-
ing and remote operability. 4 Audio
Slots can be equipped with 8 chan-
nel audio-input or output-cards to
meet customized requirements.
The P 64 includes integrated self-
monitoring and supports spare/
redundancy concepts in security-
relevant systems. Complete recall
of stored parameters and configu-
rations is possible.

Le P 64 est un système de matri-
çage modulaire compatible réseau
incluant un traitement du signal, un
contrôle du système et un fonction-
nement à distance. Quatre empla-
cements peuvent être pourvus de
cartes d’entrée ou de sortie 8
canaux selon les besoins de l’utili-
sateur. Le P 64 intègre un contrôle
de son propre fonctionnement et est
compatible avec les applications de
systèmes de sécurité nécessitant
redondance ou appareil de secours.
Il est possible de rappeler les para-
mètres ainsi que les différentes
configurations mémorisées.

Weitere P 64 Eigenschaften:

300 MIPS Rechenleistung

-

Erweiterbar auf 1900 MIPS

Ethernet Schnittstelle

- Konfi-

guration und Steuerung über
TCP/IP

CAN Schnittstelle

- Kommuni-

kation mit bis zu 100 Geräten
(z.B. DC PowerH Verstärker)

RS-232 Schnittstellen

-

Anschluss von Mediensteue-
rungen und Gebäudemanage-
mentsystemen

CobraNet

Schnittstelle

- über

optionales, redundant ausge-
legtes Netzwerkmodul

Additional P 64 features:

300 MIPS computing power

-

Expandable to 1900 MIPS

Ethernet interface

- Configura-

tion and control via TCP/IP

CAN interface

- Communication

with up to 100 external devices
(e.g. DC PowerH amplifiers)

RS-232 interface

- Connection

of media controls and building
control systems

CobraNet

interface

- optional

redundant network module

Fonctions supplémentaires du P 64:

Puissance de calcul de 300
MIPS

- Extensible à 1900 MIPS

Interface Ethernet

- Configura-

tion et contrôle via TCP/IP

Interface CAN

- Communication

avec un maximum de 100 unités
externes (par exemple les amplis
DC PowerH)

Interface RS-232

- Connexion de

contrôleurs multimedia

Interface CobraNet

- Module

en option pour réseau redondant

P 64

Digital Audio Matrix (230 V)

D 113 217

P 64

Digital Audio Matrix (120 V)

D 113 221

Inhalt

Contents

Contenu

1 x Benutzerhandbuch P 64
1 x P 64
1 x Netzkabel
2 x Stecker 6-pol., Phoenix MC
1.5/6-STF-3.81

(Nr. 18 27 74 5)

2 x CAN-Abschlusswiderstand

(120

Ω

)

1 x User manual P 64
1 x P 64
1 x Power cord
2 x Connector 6-pole, Phoenix MC
1.5/6-STF-3.81

(Nr. 18 27 74 5)

2 x CAN-Terminator

(120

Ω

)

1 x Manual d‘utilisation P 64
1 x P 64
1 x Câble d‘alimentation
2 x Connecteurs 6-pôles, Phoenix
MC 1.5/6-STF-3.81

(Nr. 18 27 74 5)

2 x Bouchons CAN

(120

Ω

)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - AC; HOST CPU

GmbH • Hirschberger Ring 45 • 94315 Straubing • Telefon (09421) 706-0 • Telefax (09421) 706-265Subject to change without prior notice. Printed in Germany V1.0 21.07.2008 D 368 198 P 64 Block Diagram AUDIO CARDS 8 Channels Analog I/O Digital I/O AUDIO CARDS 8 Channels Analog I/O Digital I/O AUDIO CAR...

Page 3 - Technical Specifications; 4 Bit linear A/D conversion, 48 Bit processing

GmbH • Hirschberger Ring 45 • 94315 Straubing • Telefon (09421) 706-0 • Telefax (09421) 706-265Subject to change without prior notice. Printed in Germany V1.0 21.07.2008 D 368 198 Technical Specifications Power Supply, Consumption 100 - 240 V AC, 50/60 Hz, 90 W max., (incl. 2 x AI-1, 2 x AO-1, 1 x C...

Page 4 - Abmessungen / Dimensions

GmbH • Hirschberger Ring 45 • 94315 Straubing • Telefon (09421) 706-0 • Telefax (09421) 706-265Subject to change without prior notice. Printed in Germany V1.0 21.07.2008 D 368 198 Abmessungen / Dimensions

Other Dynacord Models

All Dynacord Other