1
2
3
4
5
6
7
8
9
10
11
12
13
Table of Contents:
Page 2 – IMPORTANT HEALTH AND SAFETY INFORMATION; THIS IS VERY HOT
Page 3 – Unit; INSTALLATION; The use of an ELCB is recommended.
Page 4 – WARNING: THIS APPLIANCE MUST BE EARTHED; REAR ENTRY OF CABLE; must; If the mains water pressure is below1 Bar a fault; . Failure to do this could result in the boiler overfilling .
Page 5 – This connector; be pushed onto the corresponding overflow pipe on the
Page 7 – OPERATION
Page 8 – Do not use abrasive material on the outer surface of the machine.
Page 9 – TECHNICAL SPECIFICATION ALL MODELS; Tank constructed in stainless steel.; MAINTENANCE; fter initial commissioning or subsequent re-commissioning
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 - IMPORTANT HEALTH AND SAFETY INFORMATION; THIS IS VERY HOT
2 IMPORTANT HEALTH AND SAFETY INFORMATION PLEASE READ BEFORE USING YOUR NEW WATER BOILER Your new water boiler is designed to provide a constant source of near boiling water for the preparation of hot drinks. THIS IS VERY HOT All personnel must be provided with sufficient and appropriate training in...
Page 3 - Unit; INSTALLATION; The use of an ELCB is recommended.
3 INTRODUCTION Your new water boiler is designed to give years of trouble free service provided that the instructions contained in this manual are followed carefully. Your new boiler is energy efficient, simple to operate and easy to service. It is recommended that the installation is carried out by...
Page 4 - WARNING: THIS APPLIANCE MUST BE EARTHED; REAR ENTRY OF CABLE; must; If the mains water pressure is below1 Bar a fault; . Failure to do this could result in the boiler overfilling .
4 WARNING: THIS APPLIANCE MUST BE EARTHED REAR ENTRY OF CABLE Fixed or flexible cable to be connected direct to the terminal block, cable gland not utilised. BOTTOM ENTRY OF CABLE Use the cable gland. Loosen cable-gripping nut. Pass cable through gland, leaving enough free cable to connect into the ...
Page 5 - This connector; be pushed onto the corresponding overflow pipe on the
5 BOTTOM ENTRY Connect to a suitable cold drinking water supply using 15mm copper pipe and push on the ‘T’ piece supplied. The ‘T’ has been blanked off using a brass plug. Leave this plug in place. Push the ‘T’ piece firmly onto the water inlet solenoid pipe with the brass plug facing forward. Then ...
Page 7 - OPERATION
7 OPERATION (All models except WB5E) After the electrical and water connections have been made, switch the power and water supply on. The power and ready lights will flash once. The power light will then be constantly illuminated to indicate mains supply. Providing the water supply is present, the m...
Page 8 - Do not use abrasive material on the outer surface of the machine.
8 OPERATION (WB5Eonly) After the electrical and water connections have been made, switch the power and water supply on. When the power supply is switched on, the small indicator lamp on the front panel will glow orange. This means that the water is filling to the bottom probe. When the bottom probe ...
Page 9 - TECHNICAL SPECIFICATION ALL MODELS; Tank constructed in stainless steel.; MAINTENANCE; fter initial commissioning or subsequent re-commissioning
9 TECHNICAL SPECIFICATION ALL MODELS Tank constructed in stainless steel. Tank insulated from outer casing with high temperature polystyrene. All boilers have electronic control of the main functions. This means that the temperature is controlled precisely within given parameters. The circuit consta...
Page 10 - DE-SCALING All models except WB5E
10 DE-SCALING All models except WB5E To de-scale your machine, first disconnect the machine from the power supply. Remove the case by removing the top and bottom screws holding the case to the wall bracket. Drain the remaining water through the drain plug in the bottom of the tank. Remove the boiler...
12 SERVICE WARNING LIGHT (All Models except WB5E) All models except WB5E have this facility. This light is designed to help you discover the cause of any malfunction. If the circuit senses a problem, the service light will flash a number of times and then pause and repeat this sequence. Count the nu...