  • Page 2 – DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to
  • Page 3 – OWNER’S MANUAL; Figure 1 - VS24NR Shown; LOCAL CODES; OPERATION; Control Knob; CAUTION: Do not remove the
  • Page 4 – Unusually Tight Construction; per
  • Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space; Continued
  • Page 6 – Figure 2 - Ventilation Air from Inside Building; Ventilation Air From Outdoors; Do not provide openings; Figure 3 - Ventilation Air from Outdoors
  • Page 7 – INSTALLATION; CHECK GAS TYPE; B. Clearances from the top of the fireplace
  • Page 8 – Requirements for Safe Installation; Noncombustible material OK.; If Using Mantel; If using a mantel, proceed to If Using; Installing Damper; If you cannot meet these
  • Page 9 – MANTEL CLEARANCES; Figure 6 - Minimum Mantel Clearances Without Using Hood; A. If installing appliance on the floor level,; flue damper open
  • Page 10 – Installation Items Needed; Figure 10 - Attaching Damper Clamp; Damper; Manufactured Fireplace
  • Page 11 – • manual shutoff valve *; WARNING: Never connect; Figure 13 - Gas Connection
  • Page 12 – Open; Figure 15 - Checking Gas Joints; Gas Meter; Figure 14 - Manual Shutoff Valve; WARNING: Never use an open; Correct all leaks at once.
  • Page 13 – INSTALLING LOGS; Metal Grate Bar
  • Page 14 – FOR YOUR SAFETY; WARNING; Figure 20 - Control Knob and Ignitor Button Location
  • Page 15 – Shutting Off Heater; MANUAL LIGHTING; Ignitor Electrode; WARNING: Make sure the
  • Page 16 – Flame Adjustment Knob; All remote control accessories must; Thermostat Control Operation; Shows Temperature Setting; OPTIONAL REMOTE; This remote control; Do not leave the se-; Be sure to press the; The hand-held remote
  • Page 17 – WARNING: If yellow tipping; Figure 24 - Correct Pilot Flame Pattern; PILOT FLAME PATTERN; • turn heater off (see To Turn Off Gas to; Thermocouple
  • Page 18 – WARNING: Turn off heater; LOGS; Injector Holder; Figure 29 - Pilot Inlet Air Hole; Pilot Assembly; PARTS UNDER WARRANTY
  • Page 19 – POSSIBLE CAUSE; TROUBLESHOOTING; REMEDY; All troubleshooting items are listed in
  • Page 20 – nance, page 18) or replace burner orifice; OBSERVED PROBLEM
  • Page 21 – IMPORTANT
  • Page 23 – PARTS LIST; KEY
  • Page 24 – WIRING DIAGRAM; SPECIFICATIONS; When Gas Pressure Is Too Low; • pilot will not stay lit; When Gas Quality Is Bad; pilot will not stay lit
  • Page 25 – FIREPLACE HOOD; ACCESSORIES
  • Page 26 – For information about this warranty write:; KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; INTERNATIONAL; NOT A UPC
Loading the manual

UNVENTED (VENT-FREE)

NATURAL GAS LOG HEATER

ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE

OWNER’S OPERATION AND INSTALLATION MANUAL

Save this manual for future reference

WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.

— Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do

not use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas
supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

— Installation and service must be per-

formed by a qualified installer, service
agency, or the gas supplier.

WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For
assistance or additional information
consult a qualified installer, service
agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to

Air for Combustion and Ventilation section on page 4 of this manual.

®

PI

LOT

O

F

F

O

N

LO

REMOTE

OFF

ON

HI

CFS18NRA

VS18NRA
VS24NRA
VS30NRA

"A" Model

18", 24", and 30"

Remote-Ready

DESA INTERNATIONAL

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by
state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

WARNING: This appliance is for in-
stallation only in a solid-fuel burning
masonry or UL127 factory-built fire-
place, or in an approved ventless fire-
box. It is design-certified for these in-
stallations in accordance with ANS
Z21.11.2. Exception: Do not install this
appliance in a factory-built fireplace
that includes instructions stating it has
not been tested or should not be used
with unvented gas logs.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to

2 104416 UNVENTED NATURAL GAS LOG HEATER DESA INTERNATIONAL 1. This appliance is only for use with thetype of gas indicated on the rating plate.This appliance is not convertible for usewith other gases. 2. If you smell gas• shut off gas supply• do not try to light any appliance• do not touch any ele...

Page 3 - OWNER’S MANUAL; Figure 1 - VS24NR Shown; LOCAL CODES; OPERATION; Control Knob; CAUTION: Do not remove the

3 104416 OWNER’S MANUAL AUT O MAN OFF ST ATUS ON LO HI TEMP PRODUCTIDENTIFICATION Figure 1 - VS24NR Shown LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANS Z223.1, also known as NFPA 54*. *Availa...

Page 4 - Unusually Tight Construction; per

4 104416 UNVENTED NATURAL GAS LOG HEATER DESA INTERNATIONAL Today’s homes are built more energy effi-cient than ever. New materials, increasedinsulation, and new construction methodshelp reduce heat loss in homes. Home ownersweather strip and caulk around windows anddoors to keep the cold air out an...

Other Desa Models